NOVKER NK281 and Optical Power Meter: Complete Fibre Loss Test Kit Malaysia

Buying a stable light source alone does not provide a complete fibre-loss measurement solution.

The NOVKER NK281 Stable Light Source generates the optical signal, while an optical power meter measures the signal received at the opposite end. The two instruments work together to determine the total insertion loss of a fibre optic link.

For FTTH installers, network contractors and maintenance teams, purchasing both instruments as a properly matched test kit is usually more practical than buying them separately.

What Is Included in a Fibre Loss Test Kit?

A practical fibre-loss test kit should contain:

  • NOVKER NK281 Stable Light Source

  • Compatible optical power meter

  • Reference fibre patch cords

  • Suitable optical adaptors

  • Fibre connector cleaning tools

  • Charging accessories or batteries

  • Protective carrying case

Optional additions may include:

  • Visual Fault Locator

  • Fibre identifier

  • Fibre inspection microscope

  • PON optical power meter

  • OTDR

  • Replacement patch cords

  • SC/UPC and SC/APC accessories

The exact contents should match the customer’s fibre type and testing application.

How the NK281 and Power Meter Work Together

The testing process uses two ends of the fibre link.

At the transmitting end:

  • The NK281 generates a stable optical signal.

  • The technician selects the required wavelength.

  • The signal enters the fibre through a clean reference patch cord.

At the receiving end:

  • The optical power meter receives the signal.

  • The meter is set to the same wavelength.

  • The displayed result is compared with the established reference.

The difference between the reference reading and the received reading represents the total link loss in dB.

Example of a Fibre-Loss Measurement

Assume the reference optical power is:

−5.00dBm

After connecting the installed fibre link, the power meter displays:

−7.50dBm

The measured link loss is:

−5.00dBm − (−7.50dBm) = 2.50dB

The technician then compares the 2.50dB result with the calculated loss budget or project acceptance limit.

The measurement may include losses from:

  • Fibre length

  • Connectors

  • Adaptors

  • Splices

  • Patch panels

  • Passive optical components

  • Cable bending

Why Matching Wavelengths Matter

The NK281 and optical power meter must operate at the same wavelength.

For example:

NK281 output Optical power meter
850nm Set to 850nm
1300nm Set to 1300nm
1310nm Set to 1310nm
1550nm Set to 1550nm

If the NK281 transmits at 1310nm while the power meter is set to 1550nm, the displayed value may be inaccurate.

The selected wavelength must also suit the fibre type.

Recommended Kit for Single-Mode Fibre

A practical single-mode test kit may include:

  • NK281 with 1310/1550nm output

  • Optical power meter supporting 1310nm and 1550nm

  • Single-mode reference patch cords

  • SC/UPC or SC/APC adaptors

  • Fibre cleaning tools

  • Visual Fault Locator

This configuration is suitable for:

  • FTTH links

  • Telecom networks

  • Building backbones

  • Campus networks

  • Factory fibre connections

  • CCTV fibre transmission

  • Longer-distance point-to-point fibre

Testing at both 1310nm and 1550nm provides better information than testing at only one wavelength.

Recommended Kit for Multimode Fibre

For multimode fibre, the light source should provide:

  • 850nm

  • 1300nm

The kit should also include:

  • A compatible multimode optical power meter

  • Appropriate multimode reference patch cords

  • Suitable connector adaptors

  • Cleaning equipment

Multimode testing may require controlled launch conditions, especially when the work involves formal certification or high-performance data centre cabling.

Confirm the applicable project standard before offering the NK281 as a certification solution.

Why Reference Patch Cords Are Important

The reference patch cords form part of the measurement system. Low-quality or damaged patch cords can create inconsistent readings.

Suitable test cords should be:

  • Correct for the fibre type

  • Compatible with the instrument connectors

  • Clean and undamaged

  • Clearly labelled

  • Stored in a protective container

  • Reserved for testing work

A single-mode patch cord should not be substituted for a multimode reference cord without confirming the test method.

The connector polish must also match the application.

SC/UPC vs SC/APC

SC connectors may use UPC or APC polishing.

Typical identification:

  • SC/UPC: Blue

  • SC/APC: Green

APC connectors have an angled end face. UPC connectors have a different polish geometry.

Directly mating APC and UPC connectors can produce excessive loss and reflection. It may also damage the connector surfaces.

The kit should contain the correct patch cords and adaptors for the installed network.

Why Connector Cleaning Tools Should Be Included

A fibre test kit is incomplete without connector-cleaning equipment.

Contamination can cause:

  • Higher insertion loss

  • Unstable readings

  • Increased reflectance

  • Intermittent network performance

  • Contamination of the test-equipment port

  • Permanent connector damage

Recommended cleaning accessories include:

  • One-click fibre cleaner

  • Fibre cleaning sticks

  • Lint-free wipes

  • Approved fibre cleaning fluid

  • Protective dust caps

Clean connectors before establishing the reference and before testing each fibre link.

NK281 RJ45 Testing Advantage

The NK281 also provides basic RJ45 network-cable testing functions.

Depending on the selected version, technicians may use it to check:

  • Wire sequence

  • Open circuits

  • Short circuits

  • Network-cable length

This is useful for contractors who install a fibre backbone and then connect equipment through copper Ethernet cables.

Typical users include:

  • FTTH technicians

  • CCTV installers

  • Network contractors

  • Server-room technicians

  • Building maintenance teams

  • Factory IT departments

However, basic RJ45 checks do not replace a professional Cat 6 or Cat 6A cable certifier.

Should a VFL Be Added?

A Visual Fault Locator is a useful low-cost addition to the test kit.

It sends visible red light through the fibre and may help technicians:

  • Identify a fibre core

  • Check short-distance continuity

  • Find visible breaks

  • Detect severe bends

  • Verify patch-panel routing

  • Inspect poor mechanical connections

A VFL does not measure insertion loss and cannot replace the NK281 and optical power meter.

Each instrument performs a different function.

Should an OTDR Be Added?

An OTDR should be considered when the customer needs:

  • Distance to a cable break

  • Location of a poor splice

  • Individual event loss

  • Fibre length

  • Connector reflectance

  • Graphical trace documentation

  • Testing from one end

The complete professional combination is:

  • NK281 for stable optical output

  • Optical power meter for received-power measurement

  • OTDR for event location and trace analysis

  • VFL for visible fault checking

  • Fibre identifier for active-fibre identification

Smaller contractors can begin with the NK281, power meter and VFL, then add an OTDR as their project requirements grow.

Standard Power Meter or PON Power Meter?

A standard optical power meter measures optical power at a selected wavelength.

A PON optical power meter is designed to separate and measure specific upstream and downstream wavelengths on a live PON network.

Choose according to the application:

Standard optical power meter

  • Controlled loss testing

  • Point-to-point fibre

  • Passive link measurement

  • General installation work

PON optical power meter

  • Live FTTH/PON networks

  • Separate upstream and downstream readings

  • PON commissioning and troubleshooting

  • Network-service verification

A standard NK281 loss-test kit should not automatically be described as a complete live-PON testing solution.

Who Should Buy the Complete Kit?

The NK281 and optical power meter combination is suitable for:

  • Fibre optic contractors

  • FTTH installers

  • Telecom subcontractors

  • CCTV and network companies

  • Data centre maintenance teams

  • Factory IT departments

  • Building management companies

  • Technical training centres

  • Fibre installation service providers

The complete kit is particularly suitable for companies that need a practical and affordable end-to-end loss-measurement solution.

Information Needed for a Quotation

To configure the correct kit, provide:

  1. Single-mode or multimode fibre

  2. Required wavelengths

  3. SC, FC, ST or LC connections

  4. UPC or APC polish

  5. Light source only or complete kit

  6. Standard or PON power meter

  7. Required reference patch cords

  8. Need for VFL, fibre identifier or OTDR

  9. Main application

  10. Required test documentation

This prevents mismatched wavelengths and missing accessories.

Recommended MTM Precision Package

For general single-mode FTTH and network work, MTM Precision recommends starting with:

  • NOVKER NK281 1310/1550nm Stable Light Source

  • Compatible NOVKER Optical Power Meter

  • Suitable SC connection accessories

  • Two reference patch cords

  • Fibre connector cleaner

  • Visual Fault Locator

  • Protective carrying case

The final contents can be adjusted for the customer’s connector type and project requirements.