How to Measure Suspended Solids in Wastewater Malaysia
How to Measure Suspended Solids in Wastewater Malaysia
Suspended solids are an important indicator when monitoring wastewater, treatment performance and industrial discharge.
They consist of insoluble particles carried within the water, including sediment, organic matter, industrial residue and biological material.
Suspended-solids concentration is normally expressed in milligrams per litre (mg/L). Malaysian factories, wastewater-treatment operators and environmental teams can measure it using a portable suspended-solids meter or an appropriate laboratory method.
Why Measure Suspended Solids?
Excessive suspended solids may:
-
Reduce water clarity
-
Affect filtration performance
-
Increase sediment accumulation
-
Interfere with treatment processes
-
Carry other pollutants
-
Indicate poor settling or clarification
-
Affect the quality of discharged water
Routine measurements help operators identify changes before they become more serious process problems.
Where Should Wastewater Samples Be Collected?
The correct sampling point depends on the purpose of the test.
Common locations include:
-
Raw wastewater inlet
-
Equalisation tank
-
Aeration tank
-
Sedimentation tank
-
Clarifier outlet
-
Filtration inlet and outlet
-
Treated effluent outlet
-
Industrial discharge point
Testing multiple locations can help operators determine where suspended solids are being removed or where treatment performance may be declining.
Portable Meter or Laboratory Method?
Two common approaches are used for suspended-solids testing.
Portable Suspended-Solids Meter
A portable meter provides fast results for:
-
Routine operational checks
-
Field measurements
-
Comparing treatment stages
-
Process troubleshooting
-
Trend monitoring
-
Screening before laboratory testing
The Qiwei SS-500B Portable Suspended Solids Meter measures from 0 to 500 mg/L with a displayed resolution of 1 mg/L.
Laboratory Gravimetric Method
A recognised laboratory method normally involves filtering a measured volume of water, drying the retained material and determining its mass.
This approach may be required for:
-
Regulatory reporting
-
Accredited laboratory reports
-
Contractual compliance
-
Official discharge documentation
-
High-accuracy reference measurements
A portable meter is valuable for operational decisions, but users should confirm whether laboratory analysis is required for their official reporting.
Step 1: Collect a Representative Sample
Use a clean sample container and select a location that represents the actual wastewater condition.
Avoid collecting only from:
-
The water surface
-
Areas with unusually heavy sediment
-
Dead zones with little movement
-
Locations immediately beside a chemical-dosing point
If possible, follow an established sampling procedure so that results can be compared over time.
Step 2: Mix the Sample Properly
Suspended particles may settle quickly.
Before transferring the sample into the measuring bottle:
-
Mix or invert the sample gently.
-
Avoid aggressive shaking that creates bubbles.
-
Transfer the sample immediately.
-
Perform the measurement before heavier particles settle.
Use the same mixing technique each time to improve consistency.
Step 3: Inspect the Measuring Bottle
The condition of the sample bottle may affect the reading.
Check for:
-
Fingerprints
-
Water droplets
-
Scratches
-
Stains
-
Residue from previous samples
-
Air bubbles inside the sample
Clean and dry the outside of the bottle before inserting it into the instrument.
Step 4: Measure the Sample
Operate the suspended-solids meter according to the manufacturer’s instructions.
For more reliable trend comparison:
-
Use the same measuring bottle orientation
-
Keep the sample volume consistent
-
Measure within a similar time after sampling
-
Record the sampling location
-
Record the date and time
-
Note any unusual colour, foam or sediment
If the reading appears unstable, remix the sample gently and repeat the measurement.
Step 5: Record and Compare the Result
A single measurement provides limited information. The greatest operational value comes from monitoring changes over time.
Record:
-
Suspended-solids result in mg/L
-
Sampling point
-
Date and time
-
Treatment stage
-
Recent process changes
-
Chemical-dosing conditions
-
Weather or rainfall, when relevant
-
Operator observations
Operators can then compare readings before and after sedimentation, filtration or other treatment stages.
What Can Cause Incorrect Readings?
Particles Settling Too Quickly
If particles settle before measurement, the result may be lower than the actual sample condition.
Air Bubbles
Bubbles may interfere with optical measurements and produce unstable results.
Strong Sample Colour
Highly coloured industrial wastewater may affect some measurement methods. Confirm instrument suitability for unusual samples.
Dirty or Scratched Bottles
Surface contamination can affect light transmission and measurement repeatability.
Sample Outside the Measuring Range
The Qiwei SS-500B has a measurement range of 0–500 mg/L. Samples above the range require an appropriate procedure or a different instrument.
Inconsistent Sampling
Results taken from different depths or locations may not be directly comparable.
Can Turbidity Be Used Instead?
Turbidity and suspended solids are related, but they are not interchangeable.
-
Turbidity is normally reported in NTU.
-
Suspended solids are reported in mg/L.
Particle size, shape, colour and density can affect the relationship between the two measurements. There is no universal formula for converting NTU directly into mg/L.
For better wastewater-process monitoring, some facilities use both a turbidity meter and a suspended-solids meter.
Is the Qiwei SS-500B Suitable?
The SS-500B may be suitable when the customer requires:
-
Portable suspended-solids measurement
-
A 0–500 mg/L range
-
Direct results displayed in mg/L
-
Battery-powered field operation
-
Routine wastewater screening
-
Treatment-process comparison
-
Factory or environmental monitoring
Before ordering, customers should identify the expected concentration, sample type and whether the results are intended for operational or regulatory use.
Contact MTM Precision
For the Qiwei SS-500B Portable Suspended Solids Meter, wastewater-testing instruments, technical consultation or quotation, contact:
MTM Precision Sdn. Bhd.
Professional Test & Measurement Solutions Partner in Malaysia
Website: www.mtmpre.com.my
Email: mtmpre@yahoo.com
WhatsApp: +6016-660 7346
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Malaysia Coverage:
Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Terengganu, Sabah and Sarawak.
15 Sep 2026