Suspended Solids Meter Buying Guide for Water Treatment Malaysia

Suspended Solids Meter Buying Guide for Water Treatment Malaysia

A suspended-solids meter helps water-treatment operators estimate the concentration of insoluble particles in water.

Results are normally displayed in milligrams per litre (mg/L). These measurements can support wastewater monitoring, filtration checks, sedimentation control and industrial process evaluation.

Before purchasing an instrument, Malaysian customers should consider the required parameter, measuring range, sample condition, operating environment and purpose of the results.

1. Confirm the Required Parameter

The first step is to determine whether the customer needs:

  • Suspended solids in mg/L

  • Turbidity in NTU

  • Total dissolved solids in ppm

  • Conductivity in µS/cm

  • Another water-quality parameter

These measurements are related to water quality, but they are not interchangeable.

Suspended Solids

Suspended solids are insoluble particles carried within the water. Results are normally reported in mg/L.

Turbidity

Turbidity indicates how cloudy the water appears and is normally reported in NTU or FNU.

Total Dissolved Solids

TDS estimates dissolved substances in the water and is commonly displayed in ppm or mg/L.

A customer requesting TSS or suspended-solids results should not be supplied with a basic TDS or turbidity meter without first confirming the application.

2. Select the Correct Measurement Range

The instrument’s measurement range must cover the expected sample concentration.

The Qiwei SS-500B Portable Suspended Solids Meter offers:

  • Measurement range: 0–500 mg/L

  • Displayed resolution: 1 mg/L

This range can support many routine wastewater, water-treatment and industrial monitoring applications.

Before ordering, ask:

  • What is the normal suspended-solids level?

  • What is the highest expected concentration?

  • Is the sample treated water or raw wastewater?

  • Will the instrument be used before or after sedimentation?

  • Does the customer already have laboratory results for comparison?

A meter with an unsuitable range may produce over-range readings or insufficient detail at the required concentration.

3. Understand Resolution and Accuracy

Resolution and accuracy are not the same.

Resolution is the smallest displayed change on the instrument.

Accuracy describes how close the result is expected to be to the reference value under specified conditions.

A display showing 1 mg/L increments does not automatically mean every result is accurate within 1 mg/L.

Customers preparing tenders or technical submissions should review the manufacturer’s complete specification instead of relying only on the displayed resolution.

4. Identify the Purpose of Measurement

The correct instrument depends heavily on how the result will be used.

Operational Monitoring

A portable suspended-solids meter is useful for:

  • Daily process checks

  • Comparing treatment stages

  • Identifying sudden changes

  • Checking settling performance

  • Field troubleshooting

  • Monitoring filtration

  • Establishing process trends

Regulatory or Accredited Reporting

Official reporting may require a recognised laboratory method, such as gravimetric analysis performed according to the applicable procedure.

Customers should confirm the required test method with their environmental consultant, laboratory or relevant authority.

A portable meter is highly useful for screening and operational control, but it may not replace every compliance laboratory test.

5. Consider the Sample Type

Different water samples can behave differently during measurement.

Important sample characteristics include:

  • Particle size

  • Particle colour

  • Particle density

  • Rate of settling

  • Strong water colour

  • Presence of bubbles

  • Oil or chemical contamination

  • Biological material

If the customer is testing unusual industrial wastewater, provide sample information before selecting the instrument.

Highly coloured or rapidly settling samples may require additional evaluation.

6. Choose Between Portable and Benchtop Models

Portable Meter

A portable instrument is suitable when measurements are required:

  • At multiple sampling points

  • Around a wastewater-treatment plant

  • At customer sites

  • Near drains, ponds or discharge outlets

  • In locations without a fixed laboratory

  • During environmental inspections

The SS-500B can operate using an adaptor or AA batteries, making it convenient for both field and indoor use.

Benchtop Instrument

A benchtop model may be more appropriate when:

  • All testing is performed in one laboratory

  • Continuous power is available

  • Higher-resolution measurement is required

  • More advanced data functions are needed

  • Samples are prepared under controlled conditions

7. Check Calibration and Verification Requirements

Before purchasing, ask the supplier:

  • How is the instrument calibrated?

  • Are calibration standards included?

  • How often should verification be performed?

  • Is an English manual available?

  • Can a calibration or test report be supplied?

  • Are replacement measuring bottles available?

  • What maintenance is required?

Clear calibration and verification procedures are especially important when multiple operators use the same meter.

8. Review Sample Bottle Availability

The condition of the sample bottle can affect the reading.

Users should avoid bottles with:

  • Scratches

  • Fingerprints

  • Stains

  • Water droplets

  • Chemical residue

  • Permanent cloudiness

The Qiwei SS-500B package includes two measuring bottles. Customers who perform frequent testing should consider keeping replacement bottles available.

9. Evaluate Ease of Field Operation

For practical field use, consider:

  • Battery availability

  • Instrument size

  • Display readability

  • Measurement speed

  • Sample preparation

  • Cleaning requirements

  • Carrying protection

  • Automatic shutdown

  • Availability of replacement accessories

A simple instrument that operators can use consistently may provide more useful process information than a complicated instrument that is rarely used.

10. Compare Results Correctly

Portable suspended-solids readings should be compared using consistent procedures.

For better trend monitoring:

  1. Use the same sampling point.

  2. Collect samples at a similar time.

  3. Mix samples consistently.

  4. Measure before particles settle.

  5. Use clean measuring bottles.

  6. Record process conditions.

  7. Compare the portable meter periodically with laboratory results.

This allows the facility to build a meaningful relationship between portable readings and its own treatment process.

Is the Qiwei SS-500B the Right Choice?

The SS-500B may be suitable when the customer needs:

  • Portable suspended-solids testing

  • Results displayed in mg/L

  • A measurement range up to 500 mg/L

  • Battery or adaptor operation

  • Routine wastewater screening

  • Treatment-process comparison

  • An instrument for field and indoor use

Before purchasing, confirm the expected concentration and whether the results are required for operational control or official compliance reporting.

Contact MTM Precision

For the Qiwei SS-500B Portable Suspended Solids Meter, water-quality instrument selection, technical consultation or quotation, contact:

MTM Precision Sdn. Bhd.
Professional Test & Measurement Solutions Partner in Malaysia

Website: www.mtmpre.com.my
Email: mtmpre@yahoo.com
WhatsApp: +6016-660 7346

Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.

Malaysia Coverage:
Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Terengganu, Sabah and Sarawak.

15 Sep 2026