Suspended Solids Testing for Food and Beverage Wastewater Malaysia

Suspended Solids Testing for Food and Beverage Wastewater Malaysia

Food and beverage production can generate wastewater containing food particles, organic material, ingredients and cleaning residue.

Monitoring suspended solids helps factories evaluate wastewater conditions and identify changes in screening, settling, filtration and treatment performance.

A portable instrument such as the Qiwei SS-500B Suspended Solids Meter provides rapid results from 0 to 500 mg/L for routine operational monitoring.

Where Do Suspended Solids Come From?

Depending on the production process, suspended material may come from:

  • Raw ingredients

  • Food particles

  • Peels, pulp and fibres

  • Flour and starch

  • Meat or seafood residue

  • Beverage sediment

  • Dairy solids

  • Cleaning operations

  • Production spills

  • Poor screening or filtration

The concentration may change significantly between normal production, equipment washing and changeover periods.

Which Facilities May Require Testing?

Suspended-solids monitoring may be relevant to:

  • Beverage manufacturers

  • Dairy-processing plants

  • Breweries

  • Food factories

  • Sauce and seasoning producers

  • Fruit and vegetable processors

  • Meat and seafood processors

  • Bakeries

  • Central kitchens

  • Edible-oil facilities

  • Bottling plants

  • Wastewater-treatment contractors

Each facility should evaluate its own wastewater characteristics before selecting a measuring range.

Why Monitor Suspended Solids?

Routine monitoring can help personnel:

  • Detect changing wastewater loads

  • Evaluate screening performance

  • Check sedimentation efficiency

  • Compare water before and after filtration

  • Identify solids carryover

  • Monitor final treatment conditions

  • Investigate production-related changes

  • Decide when laboratory testing is required

A sudden increase may indicate a blocked screen, damaged filter, production spill or insufficient settling.

Recommended Sampling Points

Production Wastewater Inlet

This location shows the overall solids entering the treatment system.

Readings may increase during:

  • Production start-up

  • Product changeover

  • Tank cleaning

  • Floor washing

  • Raw-material handling

  • Accidental discharge

After Screening

Comparing results before and after screening can help operators assess the removal of larger particles.

Equalisation Tank

Testing the equalisation tank helps determine whether the wastewater load has become more stable before treatment.

Before and After Sedimentation

The difference between the two readings can indicate whether suspended material is settling effectively.

Before and After Filtration

An increasing outlet result may indicate filter breakthrough, incorrect operation or maintenance requirements.

Final Treatment Stage

Portable screening allows operators to identify unusual changes before sending samples for formal laboratory analysis.

About the Qiwei SS-500B

The SS-500B is a portable instrument designed to measure suspended solids in water and transparent liquid samples.

Main specifications include:

  • Measurement range: 0–500 mg/L

  • Displayed resolution: 1 mg/L

  • Power options: AC adaptor or five AA batteries

  • Sample bottles included: Two

  • Use: Field or indoor measurement

The portable design allows users to move between different sampling points around the facility.

How to Prepare a Food-Processing Wastewater Sample

Food-processing particles may settle, float or separate quickly. Consistent sample handling is important.

Step 1: Collect a Representative Sample

Avoid taking the sample only from surface foam or settled material at the bottom.

Step 2: Mix Gently

Distribute particles evenly without creating excessive bubbles.

Step 3: Fill the Measuring Bottle

Transfer the sample promptly so that heavier particles do not settle before measurement.

Step 4: Inspect the Bottle

Remove fingerprints, water droplets and residue from the outside.

Step 5: Measure Consistently

Keep the time between mixing and measurement similar for every test.

Step 6: Record the Result

Document the location, time, production activity and treatment conditions.

Common Measurement Challenges

Rapidly Settling Particles

Flour, food fragments and dense organic material may settle quickly, causing the result to decrease with time.

Floating Oil or Fat

Oil, grease and floating material may not behave like ordinary suspended particles. Customers should explain the sample condition when requesting an instrument recommendation.

Strong Sample Colour

Dark beverages, sauces and coloured ingredients may affect some optical measurement methods.

Foam and Air Bubbles

Cleaning chemicals and biological activity may create foam or bubbles that influence the reading.

High Concentration

Raw food-processing wastewater may exceed the SS-500B range of 500 mg/L. Confirm the expected concentration using existing laboratory results.

Suspended Solids vs Turbidity

Suspended-solids results are reported in mg/L, while turbidity is normally reported in NTU.

The two parameters cannot be converted using one universal formula because food particles vary in:

  • Size

  • Shape

  • Colour

  • Density

  • Reflective properties

  • Settling behaviour

Factories may use both instruments when they need particle-concentration and water-clarity information.

Suspended Solids vs TDS

TDS refers to dissolved substances and is commonly estimated through conductivity.

A basic TDS meter does not directly measure insoluble food particles or wastewater sediment.

Customers requesting suspended-solids measurement should select an instrument designed for results in mg/L.

Creating a Practical Monitoring Programme

A simple operational programme may include:

  • Testing at fixed sampling points

  • Testing at similar times each day

  • Additional testing during cleaning

  • Recording production activity

  • Comparing before and after treatment

  • Periodic comparison with laboratory results

  • Investigation when readings exceed the normal trend

Portable measurements become more valuable when they are recorded consistently over time.

Operational Monitoring and Formal Testing

The SS-500B is suitable for rapid screening and process comparison.

Official discharge or compliance reporting may require an accredited laboratory and a recognised test method.

Food and beverage facilities should confirm the required procedure with their environmental consultant, laboratory or relevant authority.

Who Can Use the SS-500B?

Potential users include:

  • Factory environmental officers

  • Wastewater operators

  • Quality-control teams

  • Maintenance departments

  • Process engineers

  • Environmental consultants

  • Water-treatment contractors

When requesting a quotation, provide the expected concentration, sample type and intended use of the result.

Contact MTM Precision

For the Qiwei SS-500B Portable Suspended Solids Meter, food and beverage wastewater instruments, technical consultation or quotation, contact:

MTM Precision Sdn. Bhd.
Professional Test & Measurement Solutions Partner in Malaysia

Website: www.mtmpre.com.my
Email: mtmpre@yahoo.com
WhatsApp: +6016-660 7346

Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.

Malaysia Coverage:
Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Terengganu, Sabah and Sarawak.

15 Sep 2026