Qiwei SS-500B vs SS-500BE Suspended Solids Meter Malaysia

Qiwei SS-500B vs SS-500BE Suspended Solids Meter Malaysia

 

The Qiwei SS-500B and SS-500BE are portable instruments for measuring suspended solids in water.

 

Both models cover the same 0–500 mg/L measurement range, but their stated display increments differ. Understanding this difference helps Malaysian customers choose a model that matches their application and budget.

 

Quick Comparison

 

SpecificationQiwei SS-500BQiwei SS-500BEParameterSuspended solidsSuspended solidsMeasurement range0–500 mg/L0–500 mg/LStated increment1 mg/L0.1 mg/LPower supplyAdaptor or AA batteriesAdaptor or AA batteriesPortable useYesYesTypical positioningRoutine monitoringFiner displayed readings

 

Both instruments are intended for portable water and wastewater measurements.

 

What Is the Main Difference?

 

The main published difference is the displayed measurement increment:

 

SS-500B: 1 mg/L

 

SS-500BE: 0.1 mg/L

 

The SS-500BE shows an additional decimal place, making it easier to observe smaller displayed changes.

 

However, a finer display does not automatically mean that every result is accurate to the last displayed digit.

 

Resolution vs Accuracy

 

Customers should understand the difference between resolution and accuracy.

 

Resolution

 

Resolution is the smallest change that can be shown on the display.

 

For example, a meter with 0.1 mg/L resolution can display:

 

10.1 mg/L

 

10.2 mg/L

 

10.3 mg/L

 

Accuracy

 

Accuracy describes how close the measured result is to the true or reference value under specified conditions.

 

A display showing 0.1 mg/L does not automatically guarantee an overall accuracy of ±0.1 mg/L.

 

Before selecting the SS-500BE for a technical specification or tender, request the complete manufacturer data covering:

 

Accuracy

 

Repeatability

 

Linearity

 

Calibration method

 

Measurement principle

 

Applicable sample conditions

 

When Is the SS-500B Suitable?

 

The SS-500B is suitable for customers who require straightforward routine measurements.

 

Potential applications include:

 

Factory wastewater screening

 

Water-treatment process checks

 

Comparing influent and effluent

 

Monitoring sedimentation

 

Checking filtration performance

 

Environmental field measurements

 

Routine trend monitoring

 

Its 1 mg/L display increment is generally practical when the customer mainly needs to identify operational changes.

 

When Should You Consider the SS-500BE?

 

Consider the SS-500BE when:

 

Smaller displayed changes are important

 

The customer specifically requests 0.1 mg/L resolution

 

The application involves lower suspended-solids levels

 

Results need to be recorded with one decimal place

 

The price difference is acceptable

 

The complete performance specification meets the customer’s requirements

 

The SS-500BE should not be selected solely because it displays more digits. Confirm that the instrument’s full performance matches the intended application.

 

Do Both Models Have the Same Range?

 

Yes. Both models are published with a range of 0–500 mg/L.

 

This means the SS-500BE does not necessarily measure a higher concentration. Its main difference is the finer displayed increment.

 

If the sample regularly exceeds 500 mg/L, neither model should be selected without confirming an approved sample-preparation procedure or a more suitable measuring range.

 

Which Model Is Better for Wastewater?

 

For general wastewater operations, the SS-500B may be sufficient when the main objective is:

 

Detecting major changes

 

Comparing treatment stages

 

Monitoring process trends

 

Screening before laboratory analysis

 

The SS-500BE may be preferred when the customer expects relatively low concentrations and wants to observe smaller displayed changes.

 

The final decision should consider sample behaviour, required accuracy and budget—not resolution alone.

 

Which Model Is Better for a Laboratory?

 

A laboratory may prefer the SS-500BE because of its finer display.

 

However, the laboratory should still confirm:

 

Required test method

 

Calibration traceability

 

Reference standards

 

Measurement uncertainty

 

Repeatability

 

Reporting requirements

 

Whether gravimetric analysis is required

 

A portable instrument may support rapid screening, but it does not automatically replace an approved laboratory TSS method.

 

Questions to Ask Before Ordering

 

Before choosing between the SS-500B and SS-500BE, provide the supplier with:

 

Expected measurement range

 

Normal and maximum concentration

 

Type of water sample

 

Sample colour

 

Whether particles settle quickly

 

Required resolution

 

Required accuracy

 

Operational or compliance purpose

 

Calibration-report requirements

 

Available budget

 

These details help prevent purchasing an instrument based only on the model name or number of display digits.

 

Practical Recommendation

 

Choose the SS-500B for proven, routine suspended-solids monitoring where a 1 mg/L displayed increment is sufficient.

 

Choose the SS-500BE when the customer specifically needs a finer 0.1 mg/L display and its complete performance specification has been confirmed.

 

For regulatory reporting, verify the required analytical method before purchasing either model.

 

Contact MTM Precision

 

For comparison of the Qiwei SS-500B and SS-500BE Portable Suspended Solids Meters, technical consultation or quotation, contact:

 

MTM Precision Sdn. Bhd.

Professional Test & Measurement Solutions Partner in Malaysia

 

Website: www.mtmpre.com.my

Email: mtmpre@yahoo.com

WhatsApp: +6016-660 7346

 

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Malaysia Coverage:

Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Terengganu, Sabah and Sarawak.


 

15 Sep 2026