Why Are Suspended Solids High in Treated Wastewater? Malaysia
Why Are Suspended Solids High in Treated Wastewater?
High suspended solids in treated wastewater may indicate a process problem, but operators should first confirm that the sample and measurement are reliable.
Possible causes include excessive incoming solids, ineffective coagulation, poor settling, sludge carryover, filter problems or an unrepresentative sample.
A portable suspended-solids meter such as the Qiwei SS-500B can help operators compare multiple treatment stages and identify where the increase occurs.
First Confirm the Reading
Before changing the treatment process, repeat the measurement correctly.
Check that:
The sample bottle is clean
There are no fingerprints or external water droplets
The sample contains no large air bubbles
The water was collected from the correct point
The sample was mixed consistently
The test was performed before particles settled
The concentration is within the instrument range
The meter has passed its verification check
An incorrect sampling or measurement procedure may create an apparent high result.
Cause 1: Incoming Solids Have Increased
Production changes may increase the amount of suspended material entering the wastewater-treatment system.
Possible reasons include:
Higher production volume
Raw-material loss
Tank or floor cleaning
Product changeover
Process leakage
Accidental discharge
Increased surface runoff
Compare the inlet reading with the facility’s normal operating trend.
If both inlet and outlet readings increase, investigate upstream production activity before adjusting the final treatment stage.
Cause 2: Screening Is Ineffective
Screens remove larger particles before the wastewater enters later treatment stages.
Suspended-solids levels may rise when:
The screen is blocked
The screen opening is unsuitable
Material bypasses the screen
Cleaning frequency is insufficient
The screen is damaged
Measure before and after screening to evaluate whether larger solids are being removed effectively.
Cause 3: Coagulation or Flocculation Is Poor
Some fine particles do not settle easily without effective coagulation and flocculation.
Poor performance may be related to:
Incorrect chemical dosage
Changing wastewater characteristics
Unsuitable pH
Insufficient mixing
Excessive mixing
Short reaction time
Chemical preparation problems
Operators should review the full treatment condition rather than increasing the chemical dosage automatically.
Cause 4: Sedimentation Is Incomplete
Particles require enough time and suitable conditions to settle.
Poor sedimentation may occur because of:
Excessive flow rate
Short retention time
Uneven flow distribution
Hydraulic surges
Light or fine particles
Disturbed settled sludge
Equipment problems
Compare suspended-solids readings before and after the sedimentation tank.
A small reduction may indicate that settling performance requires investigation.
Cause 5: Sludge Is Carrying Over
Accumulated sludge may enter the treated-water outlet when the sludge blanket becomes too high or the removal system does not operate correctly.
Possible signs include:
Visible particles at the clarifier outlet
Sudden increases during high flow
Unusual sludge movement
Rising readings after a previously stable period
Higher turbidity and suspended solids together
Review sludge removal frequency and clarifier operating conditions.
Cause 6: The Treatment System Is Hydraulically Overloaded
A sudden increase in wastewater flow may reduce treatment time and carry solids through the system.
This may occur during:
Heavy production
Cleaning cycles
Rainfall entering the system
Pumping surges
Batch discharge
Equipment malfunction
Record flow conditions together with suspended-solids readings. A high result without flow data may be difficult to diagnose.
Cause 7: The Filter Is Damaged or Exhausted
If suspended solids rise after filtration, inspect the filter stage.
Potential causes include:
Filter breakthrough
Damaged media
Incorrect backwashing
Channel formation
Blocked filters
Poor sealing
Incorrect installation
Measure samples at the filter inlet and outlet. An outlet result close to or higher than the inlet requires investigation.
Cause 8: Biological Solids Are Escaping
In biological wastewater-treatment systems, microorganisms and sludge particles may be carried into the final water.
Possible reasons include:
Poor sludge settling
Process upset
Excessive biological growth
Insufficient settling time
Clarifier disturbance
Changes in aeration or loading
Suspended-solids measurement should be reviewed together with other process information.
Cause 9: The Sample Is Unrepresentative
A sample taken near settled sludge, floating material or a turbulent outlet may not represent the normal effluent.
For consistent monitoring:
Use a fixed sampling point
Use a consistent sampling depth
Avoid surface foam
Avoid collecting settled bottom material
Record the sampling time
Follow the same procedure every day
If results vary significantly, take several samples to determine whether the water itself is inconsistent.
Cause 10: Sample Colour or Bubbles Affect the Meter
Strongly coloured industrial wastewater, foam and air bubbles may influence optical measurement.
This can occur in:
Textile wastewater
Food and beverage wastewater
Chemical processing water
Metal-treatment wastewater
Cleaning discharge
Compare the portable result with a laboratory reference when sample characteristics change.
How to Locate the Problem
Measure suspended solids systematically at:
Raw wastewater inlet
After screening
Equalisation tank
After coagulation and flocculation
Sedimentation outlet
Filter inlet
Filter outlet
Final treatment point
The stage where the reading fails to decrease—or begins to increase—provides a useful starting point for troubleshooting.
Using the Qiwei SS-500B
The Qiwei SS-500B Portable Suspended Solids Meter offers:
Measurement range: 0–500 mg/L
Displayed resolution: 1 mg/L
Battery or adaptor operation
Two measuring bottles
Portable measurement around treatment facilities
It can support rapid process comparisons without carrying every sample back to a fixed laboratory instrument.
Portable Screening and Laboratory Confirmation
Portable measurements are useful for immediate operational decisions and trend monitoring.
If the result will be used for official compliance or discharge reporting, confirm whether a recognised laboratory method is required.
An effective monitoring programme may combine:
Frequent portable screening
Routine process records
Periodic laboratory analysis
Investigation of abnormal trends
Contact MTM Precision
For the Qiwei SS-500B Portable Suspended Solids Meter, wastewater troubleshooting instruments, technical consultation or quotation, contact:
MTM Precision Sdn. Bhd.
Professional Test & Measurement Solutions Partner in Malaysia
Website: www.mtmpre.com.my
Email: mtmpre@yahoo.com
WhatsApp: +6016-660 7346
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Malaysia Coverage:
Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Terengganu, Sabah and Sarawak.
15 Sep 2026