Why Are Suspended Solids High in Treated Wastewater? Malaysia

Why Are Suspended Solids High in Treated Wastewater?

 

High suspended solids in treated wastewater may indicate a process problem, but operators should first confirm that the sample and measurement are reliable.

 

Possible causes include excessive incoming solids, ineffective coagulation, poor settling, sludge carryover, filter problems or an unrepresentative sample.

 

A portable suspended-solids meter such as the Qiwei SS-500B can help operators compare multiple treatment stages and identify where the increase occurs.

 

First Confirm the Reading

 

Before changing the treatment process, repeat the measurement correctly.

 

Check that:

 

The sample bottle is clean

 

There are no fingerprints or external water droplets

 

The sample contains no large air bubbles

 

The water was collected from the correct point

 

The sample was mixed consistently

 

The test was performed before particles settled

 

The concentration is within the instrument range

 

The meter has passed its verification check

 

An incorrect sampling or measurement procedure may create an apparent high result.

 

Cause 1: Incoming Solids Have Increased

 

Production changes may increase the amount of suspended material entering the wastewater-treatment system.

 

Possible reasons include:

 

Higher production volume

 

Raw-material loss

 

Tank or floor cleaning

 

Product changeover

 

Process leakage

 

Accidental discharge

 

Increased surface runoff

 

Compare the inlet reading with the facility’s normal operating trend.

 

If both inlet and outlet readings increase, investigate upstream production activity before adjusting the final treatment stage.

 

Cause 2: Screening Is Ineffective

 

Screens remove larger particles before the wastewater enters later treatment stages.

 

Suspended-solids levels may rise when:

 

The screen is blocked

 

The screen opening is unsuitable

 

Material bypasses the screen

 

Cleaning frequency is insufficient

 

The screen is damaged

 

Measure before and after screening to evaluate whether larger solids are being removed effectively.

 

Cause 3: Coagulation or Flocculation Is Poor

 

Some fine particles do not settle easily without effective coagulation and flocculation.

 

Poor performance may be related to:

 

Incorrect chemical dosage

 

Changing wastewater characteristics

 

Unsuitable pH

 

Insufficient mixing

 

Excessive mixing

 

Short reaction time

 

Chemical preparation problems

 

Operators should review the full treatment condition rather than increasing the chemical dosage automatically.

 

Cause 4: Sedimentation Is Incomplete

 

Particles require enough time and suitable conditions to settle.

 

Poor sedimentation may occur because of:

 

Excessive flow rate

 

Short retention time

 

Uneven flow distribution

 

Hydraulic surges

 

Light or fine particles

 

Disturbed settled sludge

 

Equipment problems

 

Compare suspended-solids readings before and after the sedimentation tank.

 

A small reduction may indicate that settling performance requires investigation.

 

Cause 5: Sludge Is Carrying Over

 

Accumulated sludge may enter the treated-water outlet when the sludge blanket becomes too high or the removal system does not operate correctly.

 

Possible signs include:

 

Visible particles at the clarifier outlet

 

Sudden increases during high flow

 

Unusual sludge movement

 

Rising readings after a previously stable period

 

Higher turbidity and suspended solids together

 

Review sludge removal frequency and clarifier operating conditions.

 

Cause 6: The Treatment System Is Hydraulically Overloaded

 

A sudden increase in wastewater flow may reduce treatment time and carry solids through the system.

 

This may occur during:

 

Heavy production

 

Cleaning cycles

 

Rainfall entering the system

 

Pumping surges

 

Batch discharge

 

Equipment malfunction

 

Record flow conditions together with suspended-solids readings. A high result without flow data may be difficult to diagnose.

 

Cause 7: The Filter Is Damaged or Exhausted

 

If suspended solids rise after filtration, inspect the filter stage.

 

Potential causes include:

 

Filter breakthrough

 

Damaged media

 

Incorrect backwashing

 

Channel formation

 

Blocked filters

 

Poor sealing

 

Incorrect installation

 

Measure samples at the filter inlet and outlet. An outlet result close to or higher than the inlet requires investigation.

 

Cause 8: Biological Solids Are Escaping

 

In biological wastewater-treatment systems, microorganisms and sludge particles may be carried into the final water.

 

Possible reasons include:

 

Poor sludge settling

 

Process upset

 

Excessive biological growth

 

Insufficient settling time

 

Clarifier disturbance

 

Changes in aeration or loading

 

Suspended-solids measurement should be reviewed together with other process information.

 

Cause 9: The Sample Is Unrepresentative

 

A sample taken near settled sludge, floating material or a turbulent outlet may not represent the normal effluent.

 

For consistent monitoring:

 

Use a fixed sampling point

 

Use a consistent sampling depth

 

Avoid surface foam

 

Avoid collecting settled bottom material

 

Record the sampling time

 

Follow the same procedure every day

 

If results vary significantly, take several samples to determine whether the water itself is inconsistent.

 

Cause 10: Sample Colour or Bubbles Affect the Meter

 

Strongly coloured industrial wastewater, foam and air bubbles may influence optical measurement.

 

This can occur in:

 

Textile wastewater

 

Food and beverage wastewater

 

Chemical processing water

 

Metal-treatment wastewater

 

Cleaning discharge

 

Compare the portable result with a laboratory reference when sample characteristics change.

 

How to Locate the Problem

 

Measure suspended solids systematically at:

 

Raw wastewater inlet

 

After screening

 

Equalisation tank

 

After coagulation and flocculation

 

Sedimentation outlet

 

Filter inlet

 

Filter outlet

 

Final treatment point

 

The stage where the reading fails to decrease—or begins to increase—provides a useful starting point for troubleshooting.

 

Using the Qiwei SS-500B

 

The Qiwei SS-500B Portable Suspended Solids Meter offers:

 

Measurement range: 0–500 mg/L

 

Displayed resolution: 1 mg/L

 

Battery or adaptor operation

 

Two measuring bottles

 

Portable measurement around treatment facilities

 

It can support rapid process comparisons without carrying every sample back to a fixed laboratory instrument.

 

Portable Screening and Laboratory Confirmation

 

Portable measurements are useful for immediate operational decisions and trend monitoring.

 

If the result will be used for official compliance or discharge reporting, confirm whether a recognised laboratory method is required.

 

An effective monitoring programme may combine:

 

Frequent portable screening

 

Routine process records

 

Periodic laboratory analysis

 

Investigation of abnormal trends

 

Contact MTM Precision

 

For the Qiwei SS-500B Portable Suspended Solids Meter, wastewater troubleshooting instruments, technical consultation or quotation, contact:

 

MTM Precision Sdn. Bhd.

Professional Test & Measurement Solutions Partner in Malaysia

 

Website: www.mtmpre.com.my

Email: mtmpre@yahoo.com

WhatsApp: +6016-660 7346

 

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Malaysia Coverage:

Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Terengganu, Sabah and Sarawak.


 

15 Sep 2026