Portable Suspended Solids Meter for Sewage Treatment Malaysia

Portable Suspended Solids Meter for Sewage Treatment Malaysia

 

Suspended-solids measurement helps sewage-treatment operators evaluate changing water conditions and compare performance across different treatment stages.

 

A portable meter provides fast operational results without requiring every process check to wait for laboratory analysis.

 

The Qiwei SS-500B Portable Suspended Solids Meter measures from 0 to 500 mg/L and can support routine screening of suitable sewage and treated-water samples.

 

What Are Suspended Solids in Sewage?

 

Suspended solids are insoluble particles carried within the water.

 

They may include:

 

Organic matter

 

Biological solids

 

Fine sediment

 

Wastewater particles

 

Treatment-process solids

 

Material entering through drainage

 

Solids carried from earlier treatment stages

 

The concentration is normally reported in milligrams per litre (mg/L).

 

Why Monitor Suspended Solids?

 

Regular monitoring helps operators:

 

Compare influent and treated water

 

Evaluate sedimentation

 

Check clarifier performance

 

Monitor filtration

 

Identify sludge carryover

 

Detect changing incoming loads

 

Investigate abnormal effluent

 

Build treatment-performance records

 

A sudden increase may indicate process disturbance, excessive flow, poor settling or equipment problems.

 

Suggested Sampling Points

 

Portable testing may be performed at:

 

Raw sewage inlet

 

After screening

 

Primary-settlement outlet

 

Biological-treatment stage

 

Secondary-clarifier outlet

 

Filter inlet

 

Filter outlet

 

Final treatment point

 

The exact sampling programme should follow the facility’s operating and reporting requirements.

 

Influent Monitoring

 

Incoming sewage conditions may change because of:

 

Peak flow

 

Rainfall

 

Industrial discharge

 

Drainage inflow

 

Cleaning activities

 

Changes in user demand

 

Pumping cycles

 

Recording influent suspended solids helps operators interpret later treatment results.

 

Sedimentation Monitoring

 

Compare samples before and after primary or secondary settling.

 

Poor removal may be associated with:

 

Short retention time

 

Hydraulic surges

 

Uneven flow

 

Light particles

 

Poor floc formation

 

Excessive sludge accumulation

 

Sludge-removal problems

 

Disturbance inside the tank

 

One unusual result should be confirmed before treatment settings are changed.

 

Clarifier Troubleshooting

 

An increasing clarifier-outlet result may indicate:

 

Sludge carryover

 

Rising sludge blanket

 

Poor settling

 

Process upset

 

Excessive flow

 

Mechanical problems

 

Uneven distribution

 

Measure the inlet and outlet during similar operating conditions and record visual observations.

 

Filtration Monitoring

 

A filter should reduce suspended particles according to its design and application.

 

Compare readings:

 

Before filtration

 

After filtration

 

Before maintenance

 

After maintenance

 

Before backwashing

 

After backwashing

 

An increasing outlet reading may indicate filter breakthrough, damaged media, bypass or incorrect operation.

 

Qiwei SS-500B Main Specifications

 

Measurement parameter: Suspended solids

 

Measurement range: 0–500 mg/L

 

Displayed resolution: 1 mg/L

 

Power supply: AC adaptor or five AA batteries

 

Sample bottles included: Two

 

Operation: Portable field or indoor use

 

Battery operation allows one meter to be moved between different treatment stages.

 

How to Collect and Measure the Sample

 

For consistent results:

 

Use a fixed sampling point.

 

Collect a representative sample.

 

Avoid surface foam and settled bottom material.

 

Mix the sample gently.

 

Avoid creating excessive air bubbles.

 

Transfer it promptly into a clean measuring bottle.

 

Clean and dry the outside of the bottle.

 

Measure before heavy particles settle.

 

Record the result immediately.

 

Use similar timing and handling for every comparison.

 

Why Might Readings Be Unstable?

 

Possible causes include:

 

Rapid particle settling

 

Floating biological material

 

Air bubbles

 

Dirty or scratched bottles

 

Different sampling depths

 

Different measurement timing

 

Strong sample colour

 

Concentration outside the meter range

 

Calibration or verification issues

 

Repeat the measurement using one well-mixed sample before concluding that the meter is faulty.

 

Suspended Solids vs Turbidity

 

Both parameters may be useful in sewage treatment.

 

Suspended solids are normally reported in mg/L.

 

Turbidity is normally reported in NTU or FNU.

 

There is no universal conversion between them because particle size, shape, colour and density affect each measurement differently.

 

A facility may monitor both parameters for a broader view of treatment performance.

 

Operational Removal Comparison

 

Operators may calculate an operational reduction using:

 

Removal (%) = [(Inlet SS − Outlet SS) ÷ Inlet SS] × 100

 

Example:

 

Inlet: 250 mg/L

 

Outlet: 50 mg/L

 

Calculated reduction: 80%

 

This comparison is meaningful only when both samples are representative and measured consistently.

 

It should not replace any required regulatory calculation or laboratory method.

 

Portable Screening and Laboratory Testing

 

The SS-500B is useful for:

 

Routine process checks

 

Rapid troubleshooting

 

Comparing treatment stages

 

Trend monitoring

 

Selecting samples for laboratory analysis

 

Formal reporting may require a recognised analytical method and an accredited laboratory result.

 

Confirm the required method with the facility’s consultant, laboratory or relevant authority.

 

Create a Monitoring Record

 

Record:

 

Date and time

 

Sampling point

 

Suspended-solids result

 

Turbidity, when available

 

pH

 

Flow condition

 

Treatment stage

 

Sludge condition

 

Filter status

 

Weather or rainfall

 

Operator comments

 

Corrective action

 

Long-term records help identify gradual deterioration and recurring treatment problems.

 

Is the SS-500B Suitable?

 

The SS-500B may be suitable when:

 

The expected concentration is within 0–500 mg/L

 

Portable operation is required

 

Results are needed in mg/L

 

The main purpose is operational screening

 

Several treatment stages must be compared

 

Battery operation is useful

 

Customers should provide their expected range and intended use when requesting a recommendation.

 

Contact MTM Precision

 

For the Qiwei SS-500B Portable Suspended Solids Meter, sewage-treatment instruments, technical consultation or quotation, contact:

 

MTM Precision Sdn. Bhd.

Professional Test & Measurement Solutions Partner in Malaysia

 

Website: www.mtmpre.com.my

Email: mtmpre@yahoo.com

WhatsApp: +6016-660 7346

 

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Malaysia Coverage:

Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Terengganu, Sabah and Sarawak.


 

15 Sep 2026