Qiwei SS-500B Suspended Solids Meter FAQ Malaysia

Qiwei SS-500B Suspended Solids Meter FAQ Malaysia

 

The Qiwei SS-500B is a portable instrument for measuring suspended solids in water and suitable transparent liquid samples.

 

It provides results in mg/L across a measurement range of 0–500 mg/L.

 

This FAQ answers common questions from Malaysian factories, wastewater operators, laboratories, consultants and water-treatment contractors.

 

What Does the Qiwei SS-500B Measure?

 

The SS-500B measures the concentration of insoluble suspended particles present in a water sample.

 

These particles may include sediment, organic matter, biological solids, food-processing residue and industrial particles.

 

Results are displayed in milligrams per litre (mg/L).

 

What Is the Measurement Range?

 

The SS-500B has a published measurement range of:

 

0–500 mg/L

 

Before ordering, customers should review their previous laboratory or process results to confirm that the expected concentration falls within this range.

 

What Is the Displayed Resolution?

 

The SS-500B displays results in increments of:

 

1 mg/L

 

Resolution should not be confused with overall accuracy. Customers requiring detailed technical performance should request the complete accuracy, repeatability and linearity specifications.

 

What Power Supply Does It Use?

 

The SS-500B can operate using:

 

An AC power adaptor

 

Five AA batteries

 

Battery operation makes the instrument convenient for field measurements and testing at several points around a wastewater-treatment facility.

 

What Is Included with the Meter?

 

The manufacturer’s published package includes:

 

SS-500B main instrument

 

Power adaptor

 

Two measuring bottles

 

Instruction manual

 

Product documentation

 

Customers should confirm the exact supplied accessories at the time of quotation.

 

Does the SS-500B Measure Turbidity?

 

No. The SS-500B is intended for suspended-solids measurement in mg/L.

 

A turbidity meter normally provides results in NTU or FNU.

 

Although suspended solids may increase turbidity, the two measurements are not interchangeable.

 

Can NTU Be Converted Directly into mg/L?

 

There is no universal conversion between NTU and mg/L.

 

The relationship depends on:

 

Particle size

 

Particle shape

 

Particle colour

 

Particle density

 

Sample composition

 

Settling behaviour

 

A conversion developed using one specific wastewater process should not automatically be applied to another sample type.

 

Is Suspended Solids the Same as TDS?

 

No.

 

Suspended solids are insoluble particles carried within water.

 

Total dissolved solids are substances dissolved in the water and are commonly estimated through conductivity.

 

A basic TDS meter does not directly measure suspended particles.

 

Is the SS-500B Suitable for Wastewater?

 

Yes, the SS-500B may be suitable for routine wastewater screening when the expected concentration is within 0–500 mg/L.

 

Applications may include:

 

Factory wastewater

 

Water-treatment processes

 

Sedimentation checks

 

Filtration monitoring

 

Food-processing wastewater

 

Environmental field testing

 

Influent and effluent comparison

 

Customers should provide information about unusual colour, oil, foam or rapidly settling particles.

 

Can It Be Used for Factory Discharge Monitoring?

 

It can support operational screening and trend monitoring.

 

For official discharge reporting, customers should confirm whether a recognised laboratory method or accredited report is required.

 

A portable meter should not automatically be treated as a replacement for every formal TSS test.

 

Does the SS-500B Require Reagents?

 

The published standard package does not list routine chemical reagents.

 

However, users should confirm the exact calibration, verification and operating requirements with the supplier before purchase.

 

How Should the Sample Be Prepared?

 

For more consistent results:

 

Collect a representative sample.

 

Mix it gently.

 

Avoid creating excessive air bubbles.

 

Transfer the sample promptly.

 

Clean and dry the outside of the measuring bottle.

 

Remove fingerprints and water droplets.

 

Measure before heavy particles settle.

 

Record the result immediately.

 

Use the same procedure when comparing readings over time.

 

Why Does the Reading Keep Changing?

 

Possible causes include:

 

Particles settling

 

Floating material

 

Air bubbles

 

Dirty sample bottles

 

Scratched bottles

 

Strong sample colour

 

Inconsistent sampling

 

Different measurement timing

 

Concentration outside the instrument range

 

Calibration or verification problems

 

Test a stable, well-mixed sample several times before concluding that the instrument is faulty.

 

Can Strongly Coloured Water Be Tested?

 

Strong sample colour may influence some optical measurement methods.

 

Customers testing textile, chemical, food-processing or metal-treatment wastewater should provide sample information before ordering.

 

Periodic comparison with laboratory results may be necessary.

 

How Should the Measuring Bottles Be Cleaned?

 

Clean the bottles immediately after use.

 

Avoid:

 

Abrasive brushes

 

Rough cleaning powder

 

Materials that leave fibres

 

Touching the optical area

 

Leaving wastewater inside overnight

 

Replace bottles that are scratched, permanently stained or cloudy.

 

How Often Should the Meter Be Calibrated?

 

The correct interval depends on:

 

Frequency of use

 

Sample condition

 

Operating environment

 

Internal quality procedures

 

Customer requirements

 

Measurement importance

 

Verification history

 

Users should perform regular verification checks and follow the manufacturer’s calibration instructions.

 

Can It Replace a Gravimetric TSS Test?

 

Not in every situation.

 

The SS-500B is useful for:

 

Rapid screening

 

Process comparison

 

Field troubleshooting

 

Routine trend monitoring

 

Selecting samples for laboratory analysis

 

A gravimetric or accredited laboratory method may still be required for official reports or compliance purposes.

 

What Is the Difference Between SS-500B and SS-500BE?

 

Both models cover 0–500 mg/L.

 

The main published difference is:

 

SS-500B: 1 mg/L stated increment

 

SS-500BE: 0.1 mg/L stated increment

 

The SS-500BE provides a finer display, but customers should compare complete accuracy and performance specifications before selecting it.

 

Is There a Lower-Range Model?

 

The Qiwei SS-100BE covers:

 

Range: 0–100 mg/L

 

Stated increment: 0.1 mg/L

 

It may be more suitable when samples consistently remain below 100 mg/L and finer displayed changes are important.

 

Who Should Consider the SS-500B?

 

Potential users include:

 

Wastewater-treatment operators

 

Factory environmental officers

 

Environmental consultants

 

Water-treatment contractors

 

Food and beverage facilities

 

Manufacturing plants

 

Laboratories

 

Educational institutions

 

Industrial maintenance teams

 

What Information Is Needed for a Quotation?

 

Please provide:

 

Water or wastewater type

 

Normal concentration

 

Maximum concentration

 

Required measurement unit

 

Field or laboratory use

 

Required resolution

 

Operational or compliance purpose

 

Calibration-report requirement

 

Delivery location

 

This information helps determine whether the SS-500B is suitable.

 

Where Can I Buy the Qiwei SS-500B in Malaysia?

 

MTM Precision supplies the Qiwei SS-500B and other water-quality testing instruments to customers throughout Malaysia.

 

Customers may contact MTM Precision for model selection, specification review, availability and formal quotation.

 

Contact MTM Precision

 

For the Qiwei SS-500B Portable Suspended Solids Meter, technical consultation or quotation, contact:

 

MTM Precision Sdn. Bhd.

Professional Test & Measurement Solutions Partner in Malaysia

 

Website: www.mtmpre.com.my

Email: mtmpre@yahoo.com

WhatsApp: +6016-660 7346

 

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Malaysia Coverage:

Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Terengganu, Sabah and Sarawak.


 

15 Sep 2026