How to Create a Wastewater Suspended Solids Monitoring Log Malaysia

How to Create a Wastewater Suspended Solids Monitoring Log Malaysia

 

A suspended-solids meter becomes more useful when every result is recorded consistently.

 

One isolated reading may show the condition of a sample at that moment, but a monitoring log helps operators identify normal ranges, gradual changes and sudden treatment problems.

 

The Qiwei SS-500B Portable Suspended Solids Meter can support routine wastewater records across a measurement range of 0–500 mg/L.

 

Why Keep a Monitoring Log?

 

A structured record helps wastewater teams:

 

Establish normal operating conditions

 

Compare treatment stages

 

Identify rising suspended solids

 

Investigate unusual results

 

Evaluate sedimentation and filtration

 

Relate readings to production activity

 

Track instrument checks

 

Decide when laboratory testing is needed

 

Provide information during internal reviews

 

Without a consistent log, it may be difficult to determine whether a reading is genuinely abnormal.

 

What Information Should Be Recorded?

 

A practical monitoring log should include:

 

FieldPurposeDate and timeIdentifies when the sample was testedSampling pointShows where the water was collectedSuspended solidsRecords the result in mg/LTurbidityAdds water-clarity information when measuredpHHelps interpret treatment conditionsFlow conditionIdentifies normal or high-flow operationProduction activityLinks changes to factory operationsChemical dosingRecords treatment adjustmentsSample appearanceNotes colour, foam and sedimentOperatorIdentifies who performed the testInstrument IDIdentifies the meter usedRemarksRecords problems or corrective action

 

The facility can add other fields based on its treatment process.

 

Select Fixed Sampling Points

 

Use clearly defined locations so that results can be compared over time.

 

Possible sampling points include:

 

Raw wastewater inlet

 

After screening

 

Equalisation tank

 

After chemical treatment

 

Sedimentation outlet

 

Filter inlet

 

Filter outlet

 

Final treatment point

 

Assign a short identification code to each location, such as:

 

INF — Influent

 

EQ — Equalisation tank

 

SED-OUT — Sedimentation outlet

 

FIL-IN — Filter inlet

 

FIL-OUT — Filter outlet

 

EFF — Final effluent

 

Clear codes reduce recording mistakes.

 

Establish a Consistent Testing Time

 

Wastewater conditions may change during production, cleaning and batch discharge.

 

Whenever possible, test at a consistent time or process stage.

 

The log should indicate whether the measurement was taken during:

 

Normal production

 

Production start-up

 

Cleaning

 

Product changeover

 

Maintenance

 

High flow

 

Rainfall

 

Treatment upset

 

A high result may be normal during one activity but unusual during another.

 

Use a Standard Measurement Procedure

 

Every operator should follow the same basic procedure.

 

Collect a representative sample.

 

Mix the sample gently.

 

Avoid creating excessive air bubbles.

 

Transfer it promptly into a clean measuring bottle.

 

Clean and dry the outside of the bottle.

 

Measure before heavy particles settle.

 

Record the result immediately.

 

Note unusual sample conditions.

 

Clean the bottle after testing.

 

Consistent measurement practice improves the value of the monitoring record.

 

Example Suspended-Solids Log

 

DateTimePointSS ResultpHProcess ConditionRemarks15/09/20269:00 AMINF220 mg/L6.8Normal productionTypical inlet15/09/20269:15 AMSED-OUT85 mg/L7.1Normal productionSettling normal15/09/20269:30 AMFIL-OUT30 mg/L7.0Normal productionNo visible solids

 

The figures above are only an example of a recording format. Each facility should establish its own operating range and acceptance criteria.

 

Establish a Baseline

 

Collect enough data during stable operation to understand the facility’s normal range.

 

A baseline should consider:

 

Different production shifts

 

Different products

 

Cleaning cycles

 

Dry and rainy conditions

 

Normal flow variation

 

Treatment-chemical changes

 

Maintenance periods

 

Do not define the normal range using only one day of measurements.

 

Set Internal Alert Levels

 

Once sufficient baseline data is available, the facility may establish internal operational alert levels.

 

An alert level can trigger actions such as:

 

Repeat the measurement

 

Check the sample bottle

 

Collect a second sample

 

Inspect sedimentation

 

Inspect the filter

 

Review chemical dosing

 

Check wastewater flow

 

Send a sample to the laboratory

 

Internal alert levels should not be confused with official discharge limits.

 

Compare Inlet and Outlet Readings

 

Recording both inlet and outlet values helps operators evaluate treatment performance.

 

An operational removal calculation may be expressed as:

 

Removal (%) = [(Inlet SS − Outlet SS) ÷ Inlet SS] × 100

 

For example:

 

Inlet: 200 mg/L

 

Outlet: 50 mg/L

 

Operational removal: 75%

 

The comparison is meaningful only when samples are representative and measured using consistent procedures.

 

Record Instrument Verification

 

The monitoring log or a separate instrument-control record should include:

 

Verification date

 

Reference or control sample

 

Expected result

 

Actual result

 

Operator

 

Acceptance status

 

Corrective action

 

Next check date

 

This helps determine whether an unusual result is caused by the process or the instrument.

 

When Should an Abnormal Result Be Investigated?

 

Investigate when:

 

The result rises suddenly

 

The outlet approaches the inlet result

 

Results remain high after filtration

 

Repeat measurements do not agree

 

The sample appearance changes

 

The meter differs significantly from laboratory results

 

The reading exceeds the instrument’s range

 

The facility’s internal alert level is exceeded

 

Always confirm the measurement before changing the treatment process.

 

Portable Monitoring and Laboratory Analysis

 

The SS-500B is suitable for routine operational screening and trend monitoring.

 

Official environmental reporting may require a recognised laboratory method or accredited report.

 

A practical system may combine:

 

Daily or shift-based portable measurements

 

Weekly trend review

 

Periodic laboratory analysis

 

Additional testing after abnormal results

 

Documented corrective action

 

About the Qiwei SS-500B

 

The SS-500B provides:

 

Measurement range: 0–500 mg/L

 

Displayed resolution: 1 mg/L

 

AC adaptor or AA-battery operation

 

Two sample bottles

 

Portable field and indoor use

 

Its portable format allows one instrument to be used at multiple treatment stages.

 

Contact MTM Precision

 

For the Qiwei SS-500B Portable Suspended Solids Meter, wastewater monitoring instruments, technical consultation or quotation, contact:

 

MTM Precision Sdn. Bhd.

Professional Test & Measurement Solutions Partner in Malaysia

 

Website: www.mtmpre.com.my

Email: mtmpre@yahoo.com

WhatsApp: +6016-660 7346

 

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Malaysia Coverage:

Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Terengganu, Sabah and Sarawak.


 

15 Sep 2026