Portable Suspended Solids Meter for Environmental Monitoring Malaysia
Portable Suspended Solids Meter for Environmental Monitoring Malaysia
Environmental consultants, field technicians and water-treatment contractors may need to check suspended solids at several locations during one site visit.
A portable instrument provides immediate results for screening and comparison without requiring every operational decision to wait for laboratory analysis.
The Qiwei SS-500B Portable Suspended Solids Meter measures from 0 to 500 mg/L and can support field monitoring of wastewater and other suitable water samples.
What Are Suspended Solids?
Suspended solids are insoluble particles carried within water.
Depending on the sampling location, they may include:
Soil
Sediment
Organic material
Biological matter
Industrial residue
Construction-related particles
Wastewater solids
Fine suspended debris
The concentration is normally reported in milligrams per litre (mg/L).
Environmental Monitoring Applications
Portable suspended-solids measurement may support:
Factory wastewater inspections
Treatment-process assessments
Drain and discharge-point screening
Pond monitoring
Surface-water investigations
Construction-site water checks
Filtration-system evaluation
Environmental troubleshooting
Comparison before and after treatment
The instrument is most valuable when measurements are recorded consistently and compared over time.
Why Use a Portable Meter?
Immediate Results
A portable meter gives the field team an indication of sample condition during the site visit.
Multiple Sampling Points
Technicians can compare readings from several locations, such as upstream, downstream, inlet and outlet points.
Faster Troubleshooting
An unusual reading can help the team decide where additional samples or inspections are required.
Process Comparison
Consultants can compare water before and after sedimentation, filtration or another treatment stage.
Field Convenience
Battery operation allows testing in locations where a power socket is unavailable.
Qiwei SS-500B Main Specifications
Measurement parameter: Suspended solids
Measurement range: 0–500 mg/L
Displayed resolution: 1 mg/L
Power supply: AC adaptor or five AA batteries
Sample bottles included: Two
Operation: Portable field or indoor use
Before ordering, confirm that the expected suspended-solids concentration is within the instrument’s range.
Planning the Sampling Locations
A useful monitoring plan may include:
A background or upstream point
The suspected pollution source
A downstream point
Treatment-system inlet
Treatment-system outlet
Drain or discharge point
A comparison or control location
Each bottle or record should be labelled clearly to prevent samples from being mixed up.
How to Collect a Representative Sample
Avoid collecting only from:
Surface foam
Settled material at the bottom
Stagnant corners
Areas immediately beside chemical dosing
Unusual turbulence, unless it is the investigation target
Use a consistent depth and sampling method when comparing locations.
Sample Handling in the Field
Suspended particles may settle during transportation or while waiting for measurement.
For better repeatability:
Mix the sample gently.
Avoid vigorous shaking.
Do not create excessive air bubbles.
Transfer the sample promptly.
Clean and dry the outside of the measuring bottle.
Measure before heavier particles settle.
Use similar timing for every test.
Record unusual colour, foam or sediment.
When samples must be transported for laboratory analysis, follow the required preservation and handling procedure.
Suspended Solids vs Turbidity
Environmental teams may measure both suspended solids and turbidity, but they are different parameters.
Suspended solids: Reported in mg/L
Turbidity: Reported in NTU or FNU
Turbidity indicates water cloudiness, while suspended-solids measurement estimates particle concentration.
There is no universal conversion between NTU and mg/L because particle size, shape, colour and density affect the readings differently.
Portable Screening vs Formal Environmental Reporting
The SS-500B is useful for:
Rapid screening
Field comparison
Process troubleshooting
Operational monitoring
Selecting samples for further analysis
Identifying unusual trends
Formal environmental reports may require an accredited laboratory and a recognised analytical method.
Before using portable readings for compliance documentation, confirm the required procedure with the relevant authority, laboratory or project specification.
Building a Field Measurement Record
Record the following for each sample:
Project or customer name
Sampling location
GPS location, when required
Date and time
Weather conditions
Recent rainfall
Sample appearance
Suspended-solids reading
Turbidity, when measured
pH and conductivity, when relevant
Operator name
Photograph reference
Laboratory sample number
Complete records make measurements easier to interpret and compare.
Common Field-Testing Problems
Samples Are Measured at Different Times
Long delays allow particles to settle and may reduce the reading.
Measuring Bottles Become Dirty
Field work increases the risk of fingerprints, dust and external water droplets.
Samples Are Not Labelled
Unclear labels may invalidate the comparison between locations.
Concentration Exceeds the Meter Range
Highly contaminated water may exceed the SS-500B range of 500 mg/L.
Sample Colour Changes
Strongly coloured industrial samples may affect some optical measurement methods.
Rainfall Changes Water Conditions
Rain can increase surface runoff, dilute wastewater or introduce sediment. Record recent weather conditions.
When Should Laboratory Testing Be Added?
Consider laboratory analysis when:
Results are required for official reporting
Portable readings are unusually high
A dispute or investigation is involved
The sample has unusual colour or composition
The portable and historical results do not agree
A recognised analytical method is specified
Project documentation requires an accredited report
Portable and laboratory measurements can complement each other.
Who Can Use the SS-500B?
The instrument may be suitable for:
Environmental consultants
Wastewater-treatment contractors
Factory environmental officers
Field service teams
Water-treatment operators
Research personnel
Educational institutions
Industrial maintenance teams
Provide the expected concentration, sample type and reporting purpose when requesting a quotation.
Contact MTM Precision
For the Qiwei SS-500B Portable Suspended Solids Meter, environmental monitoring instruments, technical consultation or quotation, contact:
MTM Precision Sdn. Bhd.
Professional Test & Measurement Solutions Partner in Malaysia
Website: www.mtmpre.com.my
Email: mtmpre@yahoo.com
WhatsApp: +6016-660 7346
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Malaysia Coverage:
Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Terengganu, Sabah and Sarawak.
15 Sep 2026