How to Check Sedimentation and Filtration Performance Malaysia

How to Check Sedimentation and Filtration Performance Malaysia

 

Sedimentation and filtration are commonly used to remove suspended particles from water and wastewater.

 

Operators can evaluate their performance by comparing suspended-solids readings before and after each treatment stage.

 

The Qiwei SS-500B Portable Suspended Solids Meter measures from 0 to 500 mg/L, allowing users to perform rapid checks at several points around a treatment facility.

 

Why Measure Before and After Treatment?

 

Looking only at the final result may show that suspended solids are high, but it may not identify which stage is responsible.

 

Testing before and after each process helps operators determine:

 

Whether sedimentation is removing particles

 

Whether the filter is performing effectively

 

Where solids are carrying over

 

Whether treatment performance is changing

 

Which stage requires inspection

 

Whether additional laboratory testing is needed

 

This process-based approach is more useful than relying on one isolated measurement.

 

Checking Sedimentation Performance

 

Sedimentation allows suspended particles to settle under suitable conditions.

 

Take one sample before the sedimentation stage and another from the outlet.

 

For a meaningful comparison:

 

Use clearly identified sampling points.

 

Collect both samples during similar operating conditions.

 

Mix each sample consistently.

 

Measure using clean bottles.

 

Record the time and process conditions.

 

Repeat the comparison over several operating cycles.

 

A clear reduction indicates that suspended material is being removed. A small reduction or increasing outlet result requires investigation.

 

Why Might Sedimentation Perform Poorly?

 

Possible causes include:

 

Excessive flow

 

Short retention time

 

Hydraulic surges

 

Uneven flow distribution

 

Very fine particles

 

Poor coagulation or flocculation

 

Incorrect chemical dosing

 

Unsuitable pH

 

Disturbed settled sludge

 

Excessive sludge accumulation

 

Sludge removal problems

 

Operators should review the complete process instead of changing chemical dosage based on one reading.

 

Checking Clarifier Performance

 

A clarifier outlet should be monitored at a consistent location.

 

An increase in suspended solids may indicate:

 

Sludge carryover

 

Rising sludge blanket

 

Flow disturbance

 

Mechanical problems

 

Poor biological settling

 

Treatment upset

 

Compare the inlet and outlet results together with visual observations, flow conditions and other process measurements.

 

Checking Filtration Performance

 

To evaluate a filter:

 

Measure the filter inlet.

 

Measure the filter outlet.

 

Use the same sampling and measurement procedure.

 

Record the result before and after maintenance.

 

Monitor the difference over time.

 

A properly operating filter should normally reduce suspended particles appropriate to its design and application.

 

Why Might the Filter Outlet Reading Increase?

 

Possible causes include:

 

Filter breakthrough

 

Damaged media

 

Channel formation

 

Incorrect backwashing

 

Excessive incoming solids

 

Poor sealing

 

Incorrect installation

 

Filter bypass

 

Inadequate maintenance

 

Sudden flow changes

 

If the outlet reading approaches or exceeds the inlet result, inspect the sampling method and filter condition.

 

Calculating Removal Percentage

 

For operational comparison, removal efficiency may be calculated as:

 

Removal (%) = [(Inlet Reading − Outlet Reading) ÷ Inlet Reading] × 100

 

Example:

 

Inlet suspended solids: 200 mg/L

 

Outlet suspended solids: 50 mg/L

 

Removal = [(200 − 50) ÷ 200] × 100 = 75%

 

This calculation is useful only when both readings are representative and measured consistently.

 

It should not replace any required regulatory calculation or laboratory procedure.

 

Use the Same Measurement Procedure

 

To compare treatment stages correctly:

 

Use the same instrument

 

Use clean sample bottles

 

Keep bottle orientation consistent

 

Remove fingerprints and water droplets

 

Avoid air bubbles

 

Measure before particles settle

 

Keep timing similar

 

Record the sampling location

 

Repeat unusual results

 

Changes in sample handling may look like changes in treatment performance.

 

About the Qiwei SS-500B

 

The SS-500B provides:

 

Measurement range: 0–500 mg/L

 

Displayed resolution: 1 mg/L

 

AC adaptor or AA-battery operation

 

Two sample bottles

 

Portable field and indoor use

 

Its portable design allows operators to move between the inlet, sedimentation tank, filter and final treatment point.

 

When Is the 0–500 mg/L Range Suitable?

 

The range may suit routine monitoring where samples remain below 500 mg/L.

 

Before ordering, review:

 

Historical laboratory results

 

Normal inlet concentration

 

Maximum expected concentration

 

Outlet concentration

 

Sample colour

 

Particle-settling behaviour

 

Raw wastewater with very high solids may require a different measuring range or an approved sample-preparation procedure.

 

Suspended Solids vs Turbidity

 

Turbidity can also be useful when checking filtration, but it is not the same as suspended-solids concentration.

 

Suspended solids are normally reported in mg/L.

 

Turbidity is normally reported in NTU or FNU.

 

The relationship depends on the particles in the water. There is no universal conversion between NTU and mg/L.

 

Facilities may use both instruments for broader process monitoring.

 

Build a Treatment-Performance Record

 

Record:

 

Date and time

 

Sampling point

 

Suspended-solids reading

 

Inlet and outlet results

 

Calculated reduction

 

Flow condition

 

Chemical dosing

 

Filter status

 

Backwash time

 

Production activity

 

Operator comments

 

Laboratory reference result

 

Long-term records help identify normal performance and gradual deterioration.

 

When Should Laboratory Testing Be Used?

 

Portable measurements support:

 

Rapid process checks

 

Troubleshooting

 

Trend monitoring

 

Maintenance decisions

 

Screening before formal testing

 

Official reporting may require a recognised laboratory method or accredited result.

 

Confirm the required procedure with the environmental consultant, laboratory or relevant authority.

 

Contact MTM Precision

 

For the Qiwei SS-500B Portable Suspended Solids Meter, sedimentation and filtration monitoring instruments, technical consultation or quotation, contact:

 

MTM Precision Sdn. Bhd.

Professional Test & Measurement Solutions Partner in Malaysia

 

Website: www.mtmpre.com.my

Email: mtmpre@yahoo.com

WhatsApp: +6016-660 7346

 

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Malaysia Coverage:

Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Terengganu, Sabah and Sarawak.


 

15 Sep 2026