How to Check Sedimentation and Filtration Performance Malaysia
How to Check Sedimentation and Filtration Performance Malaysia
Sedimentation and filtration are commonly used to remove suspended particles from water and wastewater.
Operators can evaluate their performance by comparing suspended-solids readings before and after each treatment stage.
The Qiwei SS-500B Portable Suspended Solids Meter measures from 0 to 500 mg/L, allowing users to perform rapid checks at several points around a treatment facility.
Why Measure Before and After Treatment?
Looking only at the final result may show that suspended solids are high, but it may not identify which stage is responsible.
Testing before and after each process helps operators determine:
Whether sedimentation is removing particles
Whether the filter is performing effectively
Where solids are carrying over
Whether treatment performance is changing
Which stage requires inspection
Whether additional laboratory testing is needed
This process-based approach is more useful than relying on one isolated measurement.
Checking Sedimentation Performance
Sedimentation allows suspended particles to settle under suitable conditions.
Take one sample before the sedimentation stage and another from the outlet.
For a meaningful comparison:
Use clearly identified sampling points.
Collect both samples during similar operating conditions.
Mix each sample consistently.
Measure using clean bottles.
Record the time and process conditions.
Repeat the comparison over several operating cycles.
A clear reduction indicates that suspended material is being removed. A small reduction or increasing outlet result requires investigation.
Why Might Sedimentation Perform Poorly?
Possible causes include:
Excessive flow
Short retention time
Hydraulic surges
Uneven flow distribution
Very fine particles
Poor coagulation or flocculation
Incorrect chemical dosing
Unsuitable pH
Disturbed settled sludge
Excessive sludge accumulation
Sludge removal problems
Operators should review the complete process instead of changing chemical dosage based on one reading.
Checking Clarifier Performance
A clarifier outlet should be monitored at a consistent location.
An increase in suspended solids may indicate:
Sludge carryover
Rising sludge blanket
Flow disturbance
Mechanical problems
Poor biological settling
Treatment upset
Compare the inlet and outlet results together with visual observations, flow conditions and other process measurements.
Checking Filtration Performance
To evaluate a filter:
Measure the filter inlet.
Measure the filter outlet.
Use the same sampling and measurement procedure.
Record the result before and after maintenance.
Monitor the difference over time.
A properly operating filter should normally reduce suspended particles appropriate to its design and application.
Why Might the Filter Outlet Reading Increase?
Possible causes include:
Filter breakthrough
Damaged media
Channel formation
Incorrect backwashing
Excessive incoming solids
Poor sealing
Incorrect installation
Filter bypass
Inadequate maintenance
Sudden flow changes
If the outlet reading approaches or exceeds the inlet result, inspect the sampling method and filter condition.
Calculating Removal Percentage
For operational comparison, removal efficiency may be calculated as:
Removal (%) = [(Inlet Reading − Outlet Reading) ÷ Inlet Reading] × 100
Example:
Inlet suspended solids: 200 mg/L
Outlet suspended solids: 50 mg/L
Removal = [(200 − 50) ÷ 200] × 100 = 75%
This calculation is useful only when both readings are representative and measured consistently.
It should not replace any required regulatory calculation or laboratory procedure.
Use the Same Measurement Procedure
To compare treatment stages correctly:
Use the same instrument
Use clean sample bottles
Keep bottle orientation consistent
Remove fingerprints and water droplets
Avoid air bubbles
Measure before particles settle
Keep timing similar
Record the sampling location
Repeat unusual results
Changes in sample handling may look like changes in treatment performance.
About the Qiwei SS-500B
The SS-500B provides:
Measurement range: 0–500 mg/L
Displayed resolution: 1 mg/L
AC adaptor or AA-battery operation
Two sample bottles
Portable field and indoor use
Its portable design allows operators to move between the inlet, sedimentation tank, filter and final treatment point.
When Is the 0–500 mg/L Range Suitable?
The range may suit routine monitoring where samples remain below 500 mg/L.
Before ordering, review:
Historical laboratory results
Normal inlet concentration
Maximum expected concentration
Outlet concentration
Sample colour
Particle-settling behaviour
Raw wastewater with very high solids may require a different measuring range or an approved sample-preparation procedure.
Suspended Solids vs Turbidity
Turbidity can also be useful when checking filtration, but it is not the same as suspended-solids concentration.
Suspended solids are normally reported in mg/L.
Turbidity is normally reported in NTU or FNU.
The relationship depends on the particles in the water. There is no universal conversion between NTU and mg/L.
Facilities may use both instruments for broader process monitoring.
Build a Treatment-Performance Record
Record:
Date and time
Sampling point
Suspended-solids reading
Inlet and outlet results
Calculated reduction
Flow condition
Chemical dosing
Filter status
Backwash time
Production activity
Operator comments
Laboratory reference result
Long-term records help identify normal performance and gradual deterioration.
When Should Laboratory Testing Be Used?
Portable measurements support:
Rapid process checks
Troubleshooting
Trend monitoring
Maintenance decisions
Screening before formal testing
Official reporting may require a recognised laboratory method or accredited result.
Confirm the required procedure with the environmental consultant, laboratory or relevant authority.
Contact MTM Precision
For the Qiwei SS-500B Portable Suspended Solids Meter, sedimentation and filtration monitoring instruments, technical consultation or quotation, contact:
MTM Precision Sdn. Bhd.
Professional Test & Measurement Solutions Partner in Malaysia
Website: www.mtmpre.com.my
Email: mtmpre@yahoo.com
WhatsApp: +6016-660 7346
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Malaysia Coverage:
Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Terengganu, Sabah and Sarawak.
15 Sep 2026