0-100 or 0-500 mg/L Suspended Solids Meter Selection Malaysia

0100 or 0500 mg/L Suspended Solids Meter Selection Malaysia Choosing the correct suspended-solids meter begins with the expected concentration of the water sample. A low-range instrument may provide finer displayed readings, while a wider-range instrument can accommodate higher suspended-solids levels without exceeding its limit. Qiwei offers models including the SS-100BE with a 0100 mg/L range and the SS-500B with a 0500 mg/L range. Quick Model Comparison ModelMeasurement RangeStated IncrementTypical PositioningQiwei SS-100BE0100 mg/L0.1 mg/LLower-concentration samplesQiwei SS-500B0500 mg/L1 mg/LGeneral wastewater monitoringQiwei SS-500BE0500 mg/L0.1 mg/LWider range with finer display The best model depends on the actual sample, required resolution and intended use of the result. When Should You Choose 0100 mg/L? A 0100 mg/L model may be suitable when: Suspended-solids levels are consistently low The sample is treated water Smaller displayed changes are important Historical results remain below 100 mg/L The customer requires a 0.1 mg/L display The instrument is used after filtration or treatment The SS-100BE is designed for measurements within this lower range. However, a low-range model may be unsuitable if the concentration occasionally exceeds 100 mg/L. When Should You Choose 0500 mg/L? A 0500 mg/L model provides more room for samples with changing or higher concentrations. The SS-500B may be suitable for: Factory wastewater Treatment-process comparison Influent and effluent screening Sedimentation checks Filtration monitoring Food-processing wastewater Environmental field measurements General industrial water applications Its 1 mg/L displayed increment is practical for routine operational monitoring where larger process changes are more important than small decimal differences. When Should You Consider the SS-500BE? The SS-500BE combines: A 0500 mg/L range A stated 0.1 mg/L increment It may be considered when the customer needs a wider range but also requests a finer displayed result. Before selecting it, confirm the complete accuracy, repeatability, linearity and calibration specifications. More display digits do not automatically guarantee higher overall measurement accuracy. Why Not Always Choose the Widest Range? A wider range is useful, but it is not automatically the best choice. The decision should also consider: Normal concentration Minimum concentration of interest Required display increment Measurement accuracy Sample type Budget Calibration requirements Reporting purpose If almost every sample is below 20 mg/L, a customer may prefer a model designed for lower concentrations. If readings frequently vary from 50 to 300 mg/L, a 0500 mg/L model is safer. Why Not Always Choose the Finest Display? A finer displayed increment can make small changes easier to bserve, but users must distinguish between resolution and accuracy. For example, a meter may display 25.1 mg/L without guaranteeing that the true result is accurate within ±0.1 mg/L. Review the complete technical specification rather than selecting an instrument based only on the number of decimal places. Use Historical Test Results The best way to select a range is to review previous laboratory or process data. Identify: Lowest normal result Average result Highest normal result Highest abnormal result Sample location Production condition Treatment stage Choose a range that covers normal readings and reasonable process excursions. Do not select a range that ends too close to the highest expected result. Consider the Sampling Point The required range may differ across the same treatment system. Raw Wastewater Raw wastewater may contain higher and more variable suspended-solids concentrations. After Sedimentation The concentration should normally be lower, depending on the process and sample. After Filtration Lower-range measurement may be more important when evaluating treated water. Final Treatment Stage The required meter depends on the expected result and monitoring objective. A facility testing both raw and treated water may require a wider-range model or separate instruments for different stages. What If the Sample Exceeds the Range? If the reading exceeds the instrument’s range: Do not report the maximum value as the actual concentration. Confirm that the sample and bottle are prepared correctly. Review historical laboratory results. Consult the supplier regarding a suitable instrument. Follow only an approved dilution procedure where applicable. Uncontrolled dilution may introduce significant error and may not be acceptable for formal reporting. Sample Characteristics Also Matter Range is not the only selection factor. Provide information about: Strong sample colour Rapidly settling particles Floating solids Oil and grease Foam and bubbles Chemical content Biological material Expected temperature Unusual sample conditions may influence optical measurements. Recommended Selection Questions Before requesting a quotation, answer: What parameter is required? Must the result be in mg/L? What is the normal concentration? What is the maximum concentration? Is the sample raw or treated wastewater? Is 0.1 mg/L display required? Is the meter for operational or compliance use? Is a calibration report required? Is the sample strongly coloured? Will the meter be used in the field? Practical Model Recommendation Choose the Qiwei SS-100BE when results are reliably below 100 mg/L and a finer displayed increment is required. Choose the Qiwei SS-500B for proven, general-purpose monitoring across a broader 0500 mg/L range. Consider the Qiwei SS-500BE when both the wider range and finer display are required, subject to confirmation of its complete performance specification. Contact MTM Precision For comparison of the Qiwei SS-100BE, SS-500B and SS-500BE Suspended Solids Meters, technical consultation or quotation, contact: MTM Precision Sdn. Bhd. Professional Test & Measurement Solutions Partner in Malaysia Website: www.mtmpre.com.my Email: mtmpre@yahoo.com WhatsApp: +6016-660 7346 Showroom & Service Centre No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia. Malaysia Coverage: Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Terengganu, Sabah and Sarawak.

15 Sep 2026