How to Measure Coffee TDS with Qi Wei PAL-401 Coffee Concentration Meter Malaysia

How to Measure Coffee TDS with Qi Wei PAL-401 Coffee Concentration Meter

 

Maintaining consistent coffee strength can be difficult when different baristas, grinders, coffee beans and brewing methods are involved.

 

The Qi Wei PAL-401 Coffee Concentration Meter provides a simple way to compare the concentration of brewed coffee using only approximately 0.3mL of sample.

 

It is suitable for cafés, coffee roasters, barista training centres and food and beverage users requiring basic coffee TDS comparison in Malaysia.

 

What Does the PAL-401 Measure?

 

The PAL-401 measures the concentration of dissolved coffee solids and displays the result as a percentage.

 

For example, a reading of 1.3% TDS indicates that approximately 1.3% of the beverage consists of dissolved coffee material.

 

This reading helps users evaluate whether a cup of coffee is stronger, weaker or similar to a previous brew.

 

Qi Wei PAL-401 Key Specifications

 

SpecificationPAL-401Measurement range0–22.0%Resolution0.1%Sample volumeApproximately 0.3mLMeasurement timeApproximately 3 secondsRecommended environmental temperature20–23°CPower supplyTwo AAA batteriesApproximate dimensions130 × 55 × 25mmApproximate weight100g

 

The PAL-401 is best suited to general coffee concentration comparison, training and entry-level brewing control.

 

How to Measure Coffee TDS

 

Step 1: Prepare the Instrument

 

Ensure the sample stage and optical surface are clean and dry.

 

Any remaining water, coffee residue, cleaning liquid or fingerprints may affect the next measurement.

 

Step 2: Check the Zero Reading

 

Before testing coffee, perform zero calibration according to the manufacturer’s instructions.

 

Use clean distilled or purified water if required by the operating manual. After calibration, remove the water and dry the sample stage carefully.

 

Step 3: Prepare the Coffee Sample

 

Stir the brewed coffee gently so that the sample represents the entire beverage.

 

Avoid collecting only foam, crema or suspended coffee particles. These may produce inconsistent readings.

 

For espresso, filtration may be required when a more repeatable measurement is needed because crema, carbon dioxide and fine particles can interfere with optical readings.

 

Step 4: Allow the Sample to Stabilise

 

The manufacturer specifies an environmental temperature of approximately 20–23°C.

 

Avoid placing extremely hot coffee directly onto the instrument unless the operating instructions specifically confirm that high-temperature samples are supported.

 

Allowing the sample to reach a stable temperature can improve measurement consistency.

 

Step 5: Apply the Coffee Sample

 

Place approximately 0.3mL of coffee onto the sample stage.

 

Make sure the optical surface is fully covered and that there are no large air bubbles.

 

Step 6: Start the Measurement

 

Press the measurement button and wait approximately three seconds.

 

Record the displayed TDS percentage.

 

Step 7: Repeat the Reading

 

For better confidence, measure the same coffee two or three times.

 

If the readings vary significantly:

 

Clean the sample stage

 

Mix the coffee again

 

Check for bubbles or particles

 

Confirm that the sample temperature is stable

 

Repeat the zero calibration

 

Step 8: Clean the Instrument

 

Remove the coffee immediately after testing.

 

Use clean water and a soft, non-abrasive tissue to clean the sample area. Do not scratch the optical surface or leave coffee residue to dry on it.

 

How Coffee TDS Helps Improve Consistency

 

Suppose a café’s standard filter-coffee recipe normally produces a reading of 1.3%.

 

If the next cup measures only 1.0%, possible causes may include:

 

Grind size is too coarse

 

Brewing time is too short

 

Insufficient agitation

 

Incorrect coffee dose

 

Excessive brewing water

 

Uneven coffee-bed saturation

 

If the reading is considerably higher than the café’s normal target, the beverage may be more concentrated because of a finer grind, lower beverage yield or different coffee-to-water ratio.

 

TDS does not explain every flavour characteristic, but it provides an objective number for comparing different brews.

 

Calculating Coffee Extraction Yield

 

Coffee TDS can be used together with beverage weight and dry coffee dose to estimate extraction yield.

 

Extraction Yield (%) = Beverage Weight × TDS (%) ÷ Dry Coffee Dose

 

Example:

 

Dry coffee dose: 20g

 

Beverage weight: 300g

 

Measured TDS: 1.3%

 

Calculation:

 

300 × 1.3% ÷ 20 = 19.5% extraction yield

 

This calculation helps cafés and baristas compare different grinder settings, recipes and brewing techniques.

 

Important Limitations

 

The PAL-401 has a resolution of 0.1%. It is suitable for basic comparison but may not show the small concentration changes required for professional competition, research or advanced coffee development.

 

Users requiring readings to two decimal places should consider a higher-resolution coffee refractometer.

 

The PAL-401 should also not be confused with a conventional water-quality TDS meter. A water TDS pen uses conductivity and is not designed to measure coffee extraction concentration accurately.

 

Frequently Asked Questions

 

Can the PAL-401 measure espresso?

 

Its 0–22.0% range covers both brewed coffee and concentrated espresso samples. However, espresso particles and crema should be handled carefully to obtain repeatable results.

 

How much coffee is required?

 

Approximately 0.3mL of sample is required for one measurement.

 

Can it measure drinking-water TDS?

 

The PAL-401 is intended for coffee concentration measurement. Use a conventional EC/TDS meter for drinking water, RO water, aquaculture or industrial water testing.

 

Is PAL-401 suitable for café training?

 

Yes. It can demonstrate how changes in coffee dose, beverage weight, grind size and brewing time affect coffee concentration.

 

Does TDS determine whether coffee tastes good?

 

No. TDS measures concentration, not flavour quality. Aroma, acidity, bitterness, sweetness, body and aftertaste should still be evaluated through tasting.

 

Qi Wei PAL-401 Available in Malaysia

 

The Qi Wei PAL-401 Coffee Concentration Meter is available from MTM Precision for cafés, roasters, training centres, coffee-equipment suppliers and food and beverage users throughout Malaysia.

 

Customers may visit our Puchong showroom to view the instrument and discuss its suitability for their application.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd.

 

Professional Test & Measurement Instruments • Technical Consultation • Product Demonstration • After-Sales Support

 

MTM Precision supplies professional testing and measurement instruments for industrial, laboratory, engineering, water-quality and food and beverage applications throughout Malaysia.

 

Website: www.mtmpre.com.my

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com

 

Showroom & Service Centre

 

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Customers are welcome to visit our Puchong showroom to view selected products, discuss their applications and identify a suitable testing solution with our team.


 

15 Sep 2026