Suspended Solids Testing for Palm Oil Mill Effluent Malaysia
Suspended Solids Testing for Palm Oil Mill Effluent Malaysia
Palm oil mill effluent may contain organic material, fibres, fine particles, oil and treatment-process solids.
Suspended-solids monitoring can help palm oil mills compare wastewater conditions across different treatment stages and identify changes in settling or filtration performance.
The Qiwei SS-500B Portable Suspended Solids Meter measures from 0 to 500 mg/L. It may support screening of suitable treated samples, but it should not automatically be selected for raw or highly concentrated POME.
What Are Suspended Solids in POME?
Suspended material may include:
Fine fruit fibres
Organic particles
Soil and sediment
Biological solids
Treatment-process residue
Material disturbed from ponds
Solids carried from earlier stages
The concentration is normally reported in milligrams per litre (mg/L).
Can the SS-500B Measure Raw POME?
Raw POME can be highly concentrated, dark and complex.
It may contain suspended solids far above the SS-500B’s published 0–500 mg/L range.
Strong colour, oil, high organic content and rapidly settling material may also interfere with some optical measurement methods.
Therefore, do not offer the SS-500B for raw POME without first confirming:
Expected concentration
Sample colour
Oil content
Measurement method
Required accuracy
Whether dilution is permitted
Intended use of the result
A dedicated wider-range instrument or laboratory method may be required.
Where Might the SS-500B Be Useful?
The SS-500B may be considered for samples taken at later treatment stages where suspended-solids concentrations fall within 0–500 mg/L.
Possible points include:
Treated pond outlet
Clarification outlet
Filter inlet
Filter outlet
Polishing-treatment stage
Final treated-water point
Process-comparison samples
The exact suitability depends on the sample and measurement requirement.
Why Compare Multiple Treatment Stages?
Testing only the final sample may show that suspended solids are high, but it may not reveal where removal performance changed.
Comparing several stages helps operators investigate:
Sedimentation performance
Sludge carryover
Pond disturbance
Filtration efficiency
Treatment-process changes
Unusual incoming loads
Maintenance requirements
Portable screening provides fast operational information at the site.
Sample Colour and Optical Measurement
POME may have strong natural colour.
Colour can affect the way light passes through a sample and may influence an optical suspended-solids reading.
Before relying on the result:
Compare with a laboratory reference method.
Test samples across several concentrations.
Document the treatment stage.
Check whether colour changes between samples.
Confirm the manufacturer’s sample limitations.
A relationship developed for one mill or treatment stage should not automatically be applied to another.
Oil and Floating Material
Oil and floating material may not behave like ordinary suspended particles.
They can:
Separate from the water
Coat the measuring bottle
Create a film
Trap air bubbles
Produce inconsistent samples
Contaminate the optical surface
Inspect the sample before testing and clean the measuring bottle immediately after use.
Sample-Handling Procedure
For suitable treated samples:
Select a representative sampling point.
Avoid collecting only surface oil or settled sludge.
Use a clean sampling container.
Mix the sample gently.
Avoid producing foam and air bubbles.
Transfer it promptly into the measuring bottle.
Clean and dry the bottle exterior.
Measure before particles settle.
Record the sample appearance and treatment stage.
Clean the bottle immediately after testing.
Follow site safety requirements when handling POME.
Qiwei SS-500B Main Specifications
Measurement parameter: Suspended solids
Measurement range: 0–500 mg/L
Displayed resolution: 1 mg/L
Power supply: AC adaptor or five AA batteries
Sample bottles included: Two
Operation: Portable field or indoor use
Its portable design allows operators to compare several suitable treatment-stage samples.
Suspended Solids vs Turbidity
Suspended solids and turbidity are different.
Suspended solids: Normally reported in mg/L
Turbidity: Normally reported in NTU or FNU
Strong colour and different particle characteristics can affect the relationship between these results.
There is no universal NTU-to-mg/L conversion for POME.
Suspended Solids vs Sludge Concentration
Sludge samples may contain much higher solids concentrations than treated wastewater.
The SS-500B’s 0–500 mg/L range may be unsuitable for:
Raw sludge
Concentrated biological solids
Settled pond sludge
Thickened solids
High-strength raw POME
Confirm the expected concentration before selecting an instrument.
Portable Screening vs Laboratory Testing
Portable measurement may support:
Routine process checks
Treatment-stage comparison
Troubleshooting
Filter monitoring
Trend records
Selection of samples for laboratory analysis
Official environmental reporting may require a recognised analytical method and accredited laboratory result.
Confirm the required procedure with the environmental consultant, laboratory or relevant authority.
Information Required Before Quotation
Provide:
Raw or treated POME
Sampling point
Expected suspended-solids concentration
Sample colour
Presence of oil
Required unit
Operational or compliance purpose
Required accuracy
Required calibration documentation
Delivery location
These details are necessary because not every POME sample is suitable for a 0–500 mg/L portable meter.
Practical Recommendation
Use the SS-500B only when:
The sample is taken from a suitable treatment stage
Expected concentration is within 0–500 mg/L
The sample has been evaluated for optical interference
The main purpose is operational screening
Results are periodically compared with a suitable reference method
For raw or concentrated POME, request a different instrument recommendation or use the required laboratory method.
Contact MTM Precision
For the Qiwei SS-500B Portable Suspended Solids Meter, POME and wastewater-testing instrument selection, technical consultation or quotation, contact:
MTM Precision Sdn. Bhd.
Professional Test & Measurement Solutions Partner in Malaysia
Website: www.mtmpre.com.my
Email: mtmpre@yahoo.com
WhatsApp: +6016-660 7346
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Malaysia Coverage:
Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Terengganu, Sabah and Sarawak.
15 Sep 2026