How to Check HCHO and TVOC After Home Renovation Using NOYAFA JMS11 or JMS12 Malaysia
Checking Indoor Air After Home Renovation
New paint, cabinets, flooring, wall panels, adhesive and furniture may release volatile compounds into indoor air. The smell may be especially noticeable when a renovated room remains closed for several hours.
The NOYAFA JMS11 and NOYAFA JMS12 provide a convenient way to perform an initial check for:
-
Formaldehyde—or HCHO
-
Total volatile organic compounds—or TVOC
The JMS12 also displays:
-
Temperature
-
Relative humidity
These portable instruments are useful for screening and comparison. They can help homeowners observe whether readings change between rooms, after ventilation or over several days.
However, correct measurement technique is essential. A single reading taken immediately after switching on the instrument may not represent the overall condition of the property.
Which Model Should You Use?
NOYAFA JMS11
Choose the JMS11 if you require a simple and economical detector for:
-
HCHO screening
-
TVOC screening
-
Occasional home checks
-
Comparing newly renovated and unaffected rooms
-
Checking furniture, cabinets or vehicle interiors
The JMS11 uses replaceable batteries and is suitable for straightforward testing without additional temperature and humidity measurements.
NOYAFA JMS12
Choose the JMS12 if you also want to record:
-
Room temperature
-
Relative humidity
-
HCHO
-
TVOC
The JMS12 is the more complete choice for repeated checks because temperature and humidity provide useful context when comparing measurements taken at different times.
What Should Be Checked After Renovation?
Potential sources of HCHO and TVOC may include:
-
Built-in cabinets
-
Particleboard furniture
-
Laminate flooring
-
Wooden wall panels
-
Adhesive
-
Sealant
-
Paint
-
Coating materials
-
Curtains and upholstery
-
Cleaning chemicals
-
New mattresses
-
Recently installed decorative materials
The presence of a strong smell may indicate volatile substances, but odour alone cannot identify a particular chemical or determine its concentration.
Similarly, the absence of a noticeable smell does not automatically confirm that the room contains no volatile pollutants.
When Should You Take the First Reading?
A newly renovated room may produce unstable readings while paint, adhesive and other materials are still drying.
An initial check may be conducted after the main renovation work has finished, but it should not be treated as the final result.
For a more useful evaluation, perform several checks:
-
Before ventilation
-
After ventilation
-
At the same time on another day
-
In different rooms
-
Near new materials
-
Away from the suspected source
Repeated measurements make it easier to identify patterns.
Step-by-Step Testing Method
Step 1: Remove immediate interfering products
Before testing, avoid using:
-
Perfume
-
Air freshener
-
Alcohol-based sanitiser
-
Cleaning spray
-
Insecticide
-
Aerosol products
-
Strong solvent
These products may temporarily affect semiconductor gas sensors and produce elevated readings.
Step 2: Prepare the room
Decide whether you are testing:
-
The room under normal occupied conditions
-
The room after it has remained closed
-
The effect of ventilation
Record the condition so the result can be compared correctly later.
Do not compare a closed-room reading with another reading taken while every window and door is open without noting the difference.
Step 3: Switch on the instrument
Turn on the JMS11 or JMS12 in a clean, ventilated environment whenever practical.
This helps reduce the influence of pollutants that may have accumulated around the sensor during storage.
Step 4: Place the tester correctly
Position the detector in an open area where air can flow through its ventilation openings.
Avoid placing it:
-
Directly on a newly painted surface
-
Inside a cabinet during the first general room test
-
Immediately beside an adhesive joint
-
In front of an air-conditioner outlet
-
Beside an open window
-
In direct sunlight
-
Above an open chemical container
The purpose of the first test is to understand the general room condition rather than measure the strongest possible concentration at the source.
Step 5: Allow the reading to stabilise
Do not make a decision based on the number displayed immediately after entering the room.
Allow sufficient time for the sensor to respond to the surrounding air. Keep the tester in the same location during this period.
Step 6: Record the reading
For the JMS11, record:
-
HCHO
-
TVOC
-
Location
-
Time
-
Door and window condition
For the JMS12, also record:
-
Temperature
-
Relative humidity
Step 7: Test several locations
A practical sequence for a renovated bedroom is:
-
Centre of the room
-
Near the new wardrobe
-
Near the flooring
-
Beside the bed or normal breathing area
-
Another room without recent renovation
This helps determine whether an elevated reading appears throughout the room or mainly near one material.
Step 8: Ventilate and repeat
Open the doors and windows to increase fresh-air exchange. If available, use suitable mechanical ventilation.
After ventilation, repeat the measurement at the same location.
Use the same instrument and similar measurement duration to make the comparison more meaningful.
How to Compare Before and After Ventilation
A simple test record may look like this:
| Location | Room condition | HCHO | TVOC | Temperature | Humidity |
|---|---|---|---|---|---|
| Bedroom centre | Closed | Record reading | Record reading | JMS12 | JMS12 |
| Bedroom centre | After ventilation | Record reading | Record reading | JMS12 | JMS12 |
| Near wardrobe | Closed | Record reading | Record reading | JMS12 | JMS12 |
| Unrenovated room | Normal | Record reading | Record reading | JMS12 | JMS12 |
If the reading falls after ventilation and rises again after the room remains closed, an indoor source may still be releasing volatile compounds.
This observation does not identify the exact material. Further investigation may be required.
Should You Test Inside a Cabinet?
Testing inside a cabinet can be useful, but it should be treated as a source-investigation test, not a measurement representing the entire room.
A closed cabinet may accumulate a higher concentration than the occupied area of the room.
Use two separate checks:
-
First, measure the general room.
-
Then, check inside or immediately beside the cabinet.
Clearly label the readings so they are not compared as if they were taken under identical conditions.
Why Are the Readings Higher During Hot Weather?
Higher temperatures may increase the release rate of volatile compounds from some materials.
A room that has remained closed during a hot Malaysian afternoon may therefore produce a different reading from the same room early in the morning.
This does not automatically mean that the tester is inaccurate. It may reflect a genuine change in the room environment.
The JMS12 is particularly useful for this comparison because it displays temperature and humidity alongside HCHO and TVOC.
Why Does the Reading Increase When the Air Conditioner Is Switched Off?
Several conditions may change when the air conditioner is turned off:
-
Room temperature may rise.
-
Air circulation may decrease.
-
Fresh-air exchange may remain limited.
-
Volatile compounds may accumulate.
-
Humidity may change.
Record whether the air conditioner was operating during every test. Measurements should be compared under similar conditions whenever possible.
Why Does the Reading Increase Near Cleaning Products?
Many cleaning products release volatile compounds. Perfume, sanitiser, detergent, floor cleaner and aerosol spray may affect the TVOC response.
If cleaning was recently completed:
-
Remove the chemical products from the test area.
-
Ventilate the room.
-
Allow the environment to stabilise.
-
Repeat the measurement.
-
Compare the new reading with the earlier result.
A sudden temporary increase does not necessarily mean that renovation materials are the only source.
Can JMS11 or JMS12 Confirm That a Room Is Safe?
The JMS11 and JMS12 are suitable for initial screening and comparative checks.
They should not be used alone to issue a formal declaration that a room is safe, compliant or completely free from pollutants.
Professional assessment may be required when:
-
Occupants experience persistent discomfort
-
Readings remain elevated after ventilation
-
A formal report is required
-
The property is involved in a legal dispute
-
Employee exposure must be evaluated
-
Regulatory compliance must be demonstrated
-
A specific chemical must be identified
Portable semiconductor detectors respond to environmental conditions and potentially interfering gases. Laboratory or professional testing uses different sampling and analytical methods.
What Should You Do If the Reading Remains High?
If the reading repeatedly remains elevated:
Increase ventilation
Improve outdoor-air exchange by opening suitable doors and windows or using mechanical ventilation.
Remove suspected products
Temporarily remove movable items such as new furniture, cleaning chemicals or stored solvent products and repeat the test.
Isolate the suspected area
Compare the affected room with another area that has not been renovated.
Record a trend
Take readings over several days under similar conditions.
Seek professional assessment
If the issue continues or occupants experience health concerns, consult an appropriate indoor air quality or environmental professional.
JMS11 or JMS12 for Renovation Checks?
Choose the NOYAFA JMS11 if:
-
You need basic HCHO and TVOC screening
-
You only perform occasional checks
-
You prefer replaceable batteries
-
Your main priority is affordability
Choose the NOYAFA JMS12 if:
-
You also need temperature and humidity
-
You want a more complete test record
-
You perform repeated room inspections
-
You prefer rechargeable operation
-
You want to compare changing environmental conditions
For repeated renovation checks, the JMS12 is generally the more informative model. The JMS11 remains a practical entry-level choice.
Buy NOYAFA Air Quality Testers in Malaysia
MTM Precision supplies the NOYAFA JMS11 and JMS12 for indoor air quality screening in homes, offices, rental properties and renovated premises.
Contact us to discuss:
-
JMS11 and JMS12 availability
-
Suitable model for renovation checks
-
Alternative PM2.5 and CO2 monitors
-
Product specifications
-
Basic operating guidance
-
Delivery throughout Malaysia
-
Collection from our Puchong showroom
Contact MTM Precision
MTM Precision Sdn. Bhd. (744811-A)
Telephone: +603-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my
Website: www.mtmpre.com.my
Showroom & Service Centre:
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
18 Sep 2026