TOKNAV PCR100T RTK Survey Data Controller Malaysia
TOKNAV PCR100T RTK Survey Data Controller Malaysia
The TOKNAV PCR100T is a rugged Android data controller designed for professional GNSS RTK surveying, field data collection and construction stakeout.
It combines an Android 11 operating system, physical keypad, 5.45-inch touchscreen, 9000mAh battery and IP68 protection in a portable field terminal.
The controller can be configured with compatible TOKNAV receivers and survey software for Base and Rover or network RTK applications in Malaysia.
TOKNAV PCR100T Key Specifications
Operating system: Android 11
Processor: Octa-core 2.0GHz
Memory: 4GB RAM
Internal storage: 64GB
External storage: MicroSD up to 512GB
Display: 5.45-inch
Resolution: 720 × 1440
Touchscreen: Five-point capacitive touch
Keyboard: English physical keypad
Rear camera: 13MP with flash
Battery: 9000mAh
Operating time: More than 18 hours
Charging time: ≤5 hours
Fast charging: Supported
Wi-Fi: 2.4GHz and 5GHz
Bluetooth: Bluetooth 5.0 BLE
Mobile network: 4G LTE, WCDMA and GSM bands as specified
NFC: Supported
GNSS: GPS, BeiDou, GLONASS and AGPS
Protection: IP68
Drop resistance: 1.2m pole drop
Dimensions: 221 × 78 × 16.5mm
Weight: Approximately 410.6g
Operating temperature: −20°C to +55°C
Storage temperature: −40°C to +70°C
What Does an RTK Data Controller Do?
The data controller connects the operator to the GNSS receiver and field software.
It is used to:
Create survey projects
Configure the coordinate system
Connect to the Base or Rover
Set UHF radio parameters
Enter NTRIP or CORS information
Collect field points
Perform construction stakeout
Import CAD or coordinate files
Record point codes
Calculate offsets, areas and volumes
Export survey data
Review field results
The controller is not the primary RTK positioning receiver. Its role is to manage the equipment, software and project information.
Android 11 Platform
The PCR100T runs Android 11, allowing it to support compatible Android surveying applications.
TOKNAV tSurvey 2.0 requires Android 8 or higher, so the PCR100T meets the stated operating-system requirement.
Before ordering, confirm:
Exact tSurvey version
Software licence type
Receiver compatibility
Required language
Application installation method
Software-update procedure
Offline operation
Malaysia activation
5.45-Inch Touchscreen with Physical Keypad
The controller provides both:
Capacitive touchscreen
Physical field keypad
A touchscreen is convenient for:
Map navigation
CAD viewing
Selecting points
Entering project information
Using visual stakeout functions
Physical buttons can be useful when:
The operator is wearing gloves
The screen is wet
Repeated measurements are required
Fast shortcut access is preferred
The site environment makes touchscreen-only operation difficult
Long Battery Endurance
The PCR100T uses a 9000mAh internal battery.
The manufacturer states:
More than 18 hours of operating time
Charging time of five hours or less
Fast-charging support
Actual endurance depends on:
Screen brightness
Mobile-data use
Bluetooth
Wi-Fi
GPS
Survey software
Temperature
Battery age
For full-day work, begin with a fully charged controller and carry a suitable approved power source if necessary.
4G Mobile Connectivity
The built-in mobile-network support allows the controller to connect to compatible correction services.
Possible uses include:
NTRIP connection
CORS or VRS corrections
Project-file transfer
Messaging and technical support
Online maps
WMS/WFS services
Cloud or office communication where supported
Before field deployment, test:
SIM card
APN
Mobile-data plan
Network coverage
Required LTE bands
NTRIP account
Server and mountpoint
A controller may display mobile signal while still lacking a usable correction-data connection.
Bluetooth and Wi-Fi
Bluetooth can be used to communicate with compatible receivers and peripherals.
Wi-Fi supports both 2.4GHz and 5GHz networks, allowing the controller to connect to:
Office Wi-Fi
Mobile hotspots
Site networks
Other supported wireless devices
Confirm the required receiver-connection method before the survey starts.
Camera and Field Documentation
The rear 13MP camera with flash can support:
Point photographs
Site-condition records
Control-point identification
Marking documentation
Damage reports
Technical-support evidence
Screen and equipment records
Where software integration is available, photographs may be associated with project information or used as part of the field record.
IP68 Field Protection
The PCR100T is designed to IP68 requirements and specifies resistance to a 1.2m pole drop.
This makes it more suitable for outdoor surveying than a standard consumer smartphone.
However, IP68 does not mean the controller cannot be damaged. Users should still:
Keep charging ports clean
Close protective covers
Avoid unnecessary water exposure
Protect the screen
Use the proper holder
Inspect the housing after impact
Store the controller in its case
PCR100T with TOKNAV T10 Pro
The controller can be used to manage a T10 Pro engineering RTK workflow involving:
Base and Rover setup
Network RTK
Point collection
Control survey
CAD stakeout
Road stakeout
IMU tilt measurement
Data import and export
The exact receiver and software compatibility should be confirmed for the supplied package.
PCR100T with TOKNAV T50
For the T50, confirm that the controller includes tSurvey 2.0 with permanent activation.
The required functions include:
AR stakeout
Green-laser measurement workflow
IMU tilt measurement
CAD and road stakeout
Suitable data import and export
Supplying the controller with only a basic software version may not enable the complete T50 workflow.
Controller Setup Checklist
Before going to the site:
Charge the controller fully.
Confirm the date and time.
Check available storage.
Install the approved software version.
Verify the software licence.
Pair it with the correct receiver.
Test the SIM and mobile data.
Save the required NTRIP details.
Import project files.
Check the coordinate system.
Export a sample file.
Confirm the controller holder fits securely.
Common Controller Problems
Receiver Will Not Connect
Check Bluetooth, device pairing, receiver mode and software communication settings.
No Network Correction
Check the SIM, APN, mobile data, NTRIP details, subscription and mountpoint.
CAD File Will Not Open
Confirm the file type, version, size, units and software compatibility.
Software Licence Message
Check whether the licence is permanent, expired, device-bound or affected by regional activation.
Battery Drains Quickly
Reduce screen brightness, close unused applications and check battery condition.
Touchscreen Difficult to Use
Dry the screen, remove contamination and use the physical keypad where appropriate.
What to Confirm Before Ordering
Request written confirmation of:
Controller model
Android version
Keyboard language
Mobile-network version
Charger type
tSurvey version
Permanent licence
T50 laser and AR activation
T10 Pro compatibility
Malaysia activation
Standard accessories
Warranty
Software-update entitlement
TOKNAV PCR100T Data Controller Supplier in Malaysia
Contact MTM Precision for the TOKNAV PCR100T, T50, T10 Pro, TBase and tSurvey software, including complete system configuration and technical discussion in Malaysia.
MTM Precision Sdn. Bhd. (744811-A)
Telephone: +603-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my
Website: www.mtmpre.com.my
Showroom & Service Centre:
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
18 Sep 2026