TOKNAV T50 Green Laser RTK for Inaccessible Points Malaysia

TOKNAV T50 Green Laser RTK for Inaccessible Points Malaysia

 

The TOKNAV T50 is a GNSS RTK receiver equipped with a green-laser measurement function for surveying selected points that cannot be occupied directly with a conventional survey pole.

 

Its combination of centimetre-level RTK positioning, IMU tilt measurement, AR stakeout and a green laser provides three possible ways to measure a point:

 

Conventional vertical-pole measurement

 

IMU tilt measurement

 

Green-laser measurement

 

This flexibility can be valuable for drainage, utility, construction, earthwork and infrastructure surveys in Malaysia.

 

Why Are Some Survey Points Difficult to Measure?

 

Conventional RTK normally requires the pole tip to be placed directly on the target point.

 

However, direct pole placement may be difficult or unsafe when the point is:

 

Inside a deep drain

 

At the bottom of a trench

 

Behind a fence

 

Below a retaining wall

 

Across a small water channel

 

Beside moving traffic

 

Under an overhang

 

Surrounded by construction materials

 

Located on an unsafe slope

 

Close to contaminated water

 

Beyond a safety barrier

 

Obstructed by vegetation

 

Difficult to access without entering a hazardous area

 

The T50’s laser function allows the operator to remain at a more suitable position and aim at a visible target.

 

The method must still be evaluated against the required project tolerance.

 

TOKNAV T50 Key Specifications

 

GNSS channels: 1,408

 

RTK horizontal accuracy: ±(8 mm + 1 ppm)

 

RTK vertical accuracy: ±(15 mm + 1 ppm)

 

IMU tilt range: Up to 60°

 

IMU tilt accuracy: Less than 2cm below 60°

 

Green-laser range: Up to 100m

 

Laser 3D positioning error: ≤2.5cm within 5m

 

AR stakeout: Supported

 

Integrated UHF: 410–470 MHz

 

Battery endurance: More than 16 hours in the stated network mode

 

Internal storage: 32GB

 

Protection: IP68

 

Weight: Approximately 770g

 

The stated 100m laser range should not be interpreted as guaranteed 2.5cm accuracy at 100m.

 

The published laser 3D positioning error of no more than 2.5cm applies within 5m under the specified conditions.

 

How Green-Laser RTK Works

 

The T50 first determines the GNSS position and orientation of the receiver.

 

The operator then aims the green laser at a visible target. The system uses the receiver position, laser distance and orientation information to calculate the target coordinate.

 

A complete laser measurement therefore depends on several elements:

 

Stable RTK solution

 

Correct project coordinate system

 

Accurate receiver orientation

 

Clearly visible laser spot

 

Suitable target surface

 

Stable receiver position

 

Correct software workflow

 

Proper operator technique

 

The laser does not replace GNSS corrections or project control.

 

Three Measurement Methods

 

Conventional Vertical Pole

 

Place the survey pole tip directly on the point while holding the pole vertically.

 

Use this method when:

 

The point is accessible

 

The ground is stable

 

The pole can be positioned safely

 

Satellite visibility is suitable

 

Direct occupation is preferred

 

This remains the simplest RTK measurement method for accessible points.

 

IMU Tilt Measurement

 

Place the pole tip directly on the target but tilt the pole away from an obstruction.

 

Use this method when:

 

The target can be reached

 

The receiver cannot be held vertically

 

A wall or barrier obstructs the receiver

 

The pole tip remains stable

 

The tilt remains within the supported range

 

IMU tilt changes the pole angle, but the pole tip must still touch the required point.

 

Green-Laser Measurement

 

Place the T50 at a stable location and aim the laser at the visible target.

 

Use this method when:

 

The pole tip cannot reach the point

 

Direct access is unsafe

 

A trench or drain blocks access

 

A barrier prevents occupation

 

The point is visible from a safe position

 

The required tolerance permits laser measurement

 

The operator should record that the point was obtained using the laser rather than direct occupation.

 

Suitable Green-Laser RTK Applications

 

Subject to site conditions and accuracy requirements, the T50 may assist with:

 

Drain edges

 

Drain invert features

 

Culvert openings

 

Retaining-wall points

 

Trench features

 

Excavation corners

 

Utility points

 

Fence corners

 

Building edges

 

Underside features

 

Embankment points

 

Roadside features

 

Headwalls

 

Outfall structures

 

Selected as-built details

 

Points behind physical barriers

 

Not every inaccessible point is suitable for laser measurement.

 

The target must be visible and sufficiently defined for accurate aiming.

 

Drain and Channel Survey

 

Drains frequently create access problems because they may be:

 

Deep

 

Wet

 

Slippery

 

Contaminated

 

Beside traffic

 

Protected by guardrails

 

Too narrow for safe entry

 

The T50 may allow the operator to measure a visible structural point from the drain edge.

 

Possible targets include:

 

Top of drain wall

 

Channel corner

 

Culvert edge

 

Headwall point

 

Outfall feature

 

Visible invert point

 

Avoid treating a moving water surface as a stable structural target.

 

Where possible, aim at a solid and clearly identifiable surface.

 

Trench and Excavation Survey

 

Entering an excavation to place a survey pole may expose the operator to:

 

Ground collapse

 

Falling materials

 

Machinery

 

Water

 

Restricted access

 

Unstable slopes

 

Confined-space hazards

 

The T50 may support selected observations from outside the excavation when the target is clearly visible.

 

Possible applications include:

 

Trench-edge measurement

 

Excavation corners

 

Selected bottom points

 

Pipe-route documentation

 

Formation checks

 

As-built utility positions

 

The instrument does not remove the need for excavation risk assessment, barriers and site-safety procedures.

 

Measuring Behind a Fence or Barrier

 

A fence, guardrail or temporary barricade may prevent the survey pole from reaching the required point.

 

If the target remains visible, the operator may position the T50 on the accessible side and aim through or over the obstruction.

 

Before accepting the result:

 

Confirm the exact target

 

Check the laser spot

 

Stabilise the receiver

 

Repeat the measurement

 

Compare with nearby points

 

Record the observation method

 

Do not aim through glass or another transparent surface without first verifying the effect on the measurement.

 

Retaining Walls and Structural Features

 

Possible laser targets around retaining walls include:

 

Top corners

 

Wall edges

 

Toe points

 

Drain openings

 

Visible joints

 

External as-built details

 

Surveyors must distinguish clearly between:

 

Top of wall

 

Front face

 

Back face

 

Toe

 

Base

 

Corner

 

A technically successful laser observation is still wrong if the operator aims at the wrong feature.

 

Target-Surface Considerations

 

Laser performance can vary according to the target surface.

 

Potentially difficult surfaces include:

 

Dark surfaces

 

Highly reflective materials

 

Wet concrete

 

Shiny metal

 

Glass

 

Moving water

 

Vegetation

 

Uneven soil

 

Small pipes

 

Surfaces under strong sunlight

 

A large, light-coloured, matte and clearly defined surface is generally easier to aim at than a small, dark or reflective target.

 

If the laser spot cannot be confirmed confidently, use another measurement method.

 

Effect of Distance

 

Longer distance can make precise aiming more difficult.

 

As the distance increases:

 

The target appears smaller

 

Hand movement has a larger effect

 

The laser spot may become harder to see

 

Surface identification becomes more difficult

 

Angular uncertainty has greater influence

 

Obstructions may interrupt the sight path

 

The maximum laser range is not the same as the recommended working distance for every precision task.

 

For important measurements:

 

Work at a shorter practical distance

 

Repeat the observation

 

Test against a known point

 

Compare with another method

 

Working in Bright Sunlight

 

Green lasers are generally easier to see than red lasers, but strong Malaysian sunlight can still reduce laser-spot visibility.

 

To improve field use:

 

Shorten the measurement distance

 

Change the viewing angle

 

Use a shaded target where possible

 

Avoid glare

 

Confirm the target through the software display

 

Repeat the measurement

 

Use a suitable target when practical

 

Never accept a measurement when the operator cannot determine where the laser is pointing.

 

Working Near Water

 

Water can create reflection and target-definition problems.

 

When surveying a drain or channel:

 

Avoid aiming only at the water surface

 

Identify a solid structural point

 

Watch for reflected laser light

 

Repeat the observation

 

Compare surrounding elevations

 

Record water conditions

 

Use another method if the target is unclear

 

The laser function does not measure a reliable drain invert through opaque or moving water.

 

Working Near Traffic

 

Roadside drains, kerbs and utilities may require measurements close to live traffic.

 

The T50 may reduce some direct-access requirements, but operators must still use:

 

Traffic-management procedures

 

High-visibility clothing

 

Warning signs

 

Safe equipment positions

 

Approved working zones

 

A second person where required

 

Appropriate site supervision

 

Do not step into a traffic lane merely to improve laser visibility.

 

Practical Laser-Measurement Workflow

 

1. Confirm the Required Accuracy

 

Determine whether the point is intended for:

 

Preliminary survey

 

Topographic mapping

 

Progress monitoring

 

Construction control

 

Final as-built records

 

Structural setting out

 

Laser measurement may be suitable for one purpose but insufficient for another.

 

2. Configure the Project

 

Confirm:

 

Datum

 

Projection

 

Coordinate zone

 

Vertical datum

 

Units

 

Localization

 

Geoid model

 

Antenna or instrument settings

 

3. Connect to RTK Corrections

 

Use:

 

TOKNAV TBase

 

Compatible local Base

 

CORS

 

VRS

 

NTRIP service

 

Confirm a stable Fixed solution.

 

4. Measure a Known Point

 

Check the T50 against an approved project-control point.

 

5. Test the Laser

 

Measure a target that can also be occupied directly with the pole.

 

Compare the laser-derived coordinate with the conventional measurement.

 

This gives the operator a practical site check before measuring inaccessible points.

 

6. Select a Stable Instrument Position

 

Stand on firm ground and avoid locations where the operator or receiver may move during aiming.

 

7. Identify the Exact Feature

 

Decide whether the required target is:

 

Edge

 

Corner

 

Centre

 

Top

 

Bottom

 

Face

 

Invert

 

Opening

 

8. Aim the Laser

 

Confirm that the green laser spot is on the intended surface rather than a nearby object.

 

9. Allow the Measurement to Stabilise

 

Monitor RTK status and follow the software workflow.

 

10. Repeat the Observation

 

Repeat important measurements and compare the results.

 

Where possible, change the setup slightly and obtain an independent observation.

 

11. Record the Method

 

Use a point code or note to identify laser-measured points.

 

This helps the office team distinguish them from direct pole observations.

 

Quality-Control Method

 

A useful field-verification process is:

 

Select an accessible test point.

 

Measure it using a vertical pole.

 

Measure the same point using IMU tilt.

 

Measure it using the green laser.

 

Compare the three coordinates.

 

Repeat from another position.

 

Record the differences.

 

This test helps the operator understand the system’s behaviour under the actual site conditions.

 

Common Green-Laser Measurement Mistakes

 

Assuming 100m range means equal accuracy at every distance

 

Aiming at an unclear surface

 

Measuring moving water

 

Accepting a Float solution

 

Moving the receiver while aiming

 

Selecting the wrong structural feature

 

Using the laser where direct pole measurement is available and more appropriate

 

Failing to repeat important points

 

Ignoring strong sunlight or reflection

 

Using an incorrect coordinate system

 

Failing to check project control

 

Mixing laser and direct observations without field notes

 

Relying on laser measurement for work requiring tighter accuracy than demonstrated

 

When Not to Use the Laser Function

 

Use another method when:

 

The target cannot be seen

 

The laser spot cannot be confirmed

 

The surface is moving

 

The surface is highly reflective

 

Vegetation blocks the target

 

The required tolerance is too tight

 

GNSS conditions are unstable

 

The receiver cannot be held steadily

 

The measurement cannot be checked

 

Site rules prohibit the intended setup

 

A Total Station, reflectorless Total Station, level, tape measurement or direct-access survey may be more appropriate depending on the task.

 

T50 Versus T10 Pro

 

Choose the TOKNAV T10 Pro when:

 

Most points are accessible

 

Conventional pole measurement is sufficient

 

IMU tilt solves the common obstructions

 

Standard topographic and construction survey is the priority

 

A lower equipment cost is preferred

 

Choose the TOKNAV T50 when:

 

Inaccessible points occur regularly

 

Drain and trench surveys are common

 

Green-laser measurement provides practical value

 

AR stakeout is required

 

One receiver must handle a wider range of site conditions

 

Both receivers provide the same published standard RTK accuracy, but the T50 adds the specialised laser workflow.

 

T50 with TOKNAV TBase

 

The T50 can be paired with the TOKNAV TBase for an independent Base and Rover system.

 

The TBase provides:

 

1,408 GNSS channels

 

410–470 MHz UHF

 

Selectable 1W, 2W and 5W transmission power

 

13,800mAh battery

 

More than 12 hours of stated Base operation at 5W

 

IP68 protection

 

32GB storage

 

Base coordinates, frequency, protocol and regional configuration must be set correctly before field use.

 

Software and Controller Requirements

 

A complete T50 package should include a compatible field controller and the correct version of tSurvey 2.0.

 

Before ordering, confirm:

 

Green-laser workflow is enabled

 

AR stakeout is enabled

 

Software licence is permanent

 

Licence is activated for Malaysia

 

Controller is compatible

 

Required import and export formats are supported

 

Firmware and software updates are available

 

Training covers laser operation

 

A T50 receiver without the correct software configuration may not provide the intended complete workflow.

 

Questions to Ask Before Buying

 

Ask the supplier:

 

Is the receiver permanently activated for Malaysia?

 

Does the package include tSurvey 2.0?

 

Are laser and AR functions fully enabled?

 

Is the software licence permanent?

 

Which controller is included?

 

What accessories are supplied?

 

Can the laser function be demonstrated?

 

What field checks are recommended?

 

What warranty and technical support are available?

 

Is Base and Rover training included?

 

TOKNAV T50 Green Laser RTK Supplier in Malaysia

 

Contact MTM Precision for the TOKNAV T50, T10 Pro, TBase, PCR100T and tSurvey 2.0, including green-laser RTK demonstration, configuration, quotation and technical discussion in Malaysia.

 

MTM Precision Sdn. Bhd. (744811-A)

 

Telephone: +603-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my

Website: www.mtmpre.com.my

 

Showroom & Service Centre:

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.


 

18 Sep 2026