Why TOKNAV RTK Stays Float and Cannot Get Fixed Malaysia

Why TOKNAV RTK Stays Float and Cannot Get Fixed Malaysia

 

A GNSS RTK receiver normally needs a stable correction stream and sufficiently good satellite observations before it can calculate a Fixed solution.

 

If a TOKNAV T50 or T10 Pro remains in Float mode, takes too long to become Fixed or repeatedly changes between Fixed and Float, the problem may involve:

 

Satellite obstruction

 

Multipath

 

Interrupted correction data

 

Incorrect UHF settings

 

Network RTK connection problems

 

Excessive distance from the Base

 

Poor Base-station position

 

Antenna or accessory problems

 

Incorrect receiver configuration

 

Troubleshooting should begin by separating the GNSS problem from the correction-communication problem.

 

What Do Single, Float and Fixed Mean?

 

Single

 

The receiver is calculating a standalone GNSS position without a fully usable RTK correction solution.

 

Its accuracy is normally insufficient for centimetre-level survey work.

 

Float

 

The Rover is using correction information, but the carrier-phase ambiguities have not been resolved reliably.

 

A Float position may appear close to the correct location, but it should not automatically be accepted for precision surveying or construction stakeout.

 

Fixed

 

The receiver has resolved the RTK carrier-phase solution.

 

Under suitable conditions, the TOKNAV T50 and T10 Pro provide published RTK accuracy of:

 

Horizontal: ±(8 mm + 1 ppm)

 

Vertical: ±(15 mm + 1 ppm)

 

Fixed status must still be verified against known project control.

 

First Question: Is the Rover Receiving Corrections?

 

Before investigating satellites, confirm whether correction data is reaching the Rover.

 

Check:

 

Correction-data indicator

 

Correction-data age

 

UHF receive status

 

NTRIP connection status

 

Mountpoint

 

Data volume

 

Base identification

 

RTK mode

 

If correction-data age continues increasing, the Rover may have stopped receiving corrections.

 

If there is no correction stream, the receiver cannot normally maintain a proper RTK Fixed solution.

 

Read the Correction-Data Age

 

Correction age shows how recently the Rover received usable correction information.

 

Normal Behaviour

 

The value remains low and updates continuously.

 

Possible Communication Failure

 

The value:

 

Increases steadily

 

Freezes

 

Disappears

 

Changes irregularly

 

Returns only when the Rover moves closer to the Base

 

For UHF operation, investigate the radio link.

 

For network RTK, investigate the mobile and NTRIP connection.

 

Cause 1: Poor Satellite Visibility

 

RTK works best with a clear view of the sky.

 

Common obstructions include:

 

Buildings

 

Trees

 

Roofs

 

Bridges

 

Retaining walls

 

Containers

 

Excavation sides

 

Large vehicles

 

Construction machinery

 

These objects can reduce the number and quality of usable satellite signals.

 

Test

 

Move the Rover to an open area and hold it stationary.

 

If the receiver becomes Fixed quickly in open sky, the original location is probably causing the problem.

 

Cause 2: Multipath

 

Multipath occurs when satellite signals reflect from nearby surfaces before reaching the antenna.

 

Common reflecting surfaces include:

 

Glass buildings

 

Metal roofs

 

Vehicles

 

Steel structures

 

Water

 

Concrete walls

 

Containers

 

Construction machinery

 

Multipath can make the observations inconsistent and prevent a reliable ambiguity solution.

 

A receiver showing many satellites may still struggle to become Fixed if the signal quality is poor.

 

Cause 3: The Base Has Poor Sky Visibility

 

The Rover depends on correction data generated from the Base observations.

 

If the TBase is installed:

 

Beside a building

 

Under a roof

 

Beneath trees

 

Close to a wall

 

Near metal structures

 

Inside a vehicle

 

At the bottom of a deep excavation

 

the Base observations may be poor even if the Rover is in open sky.

 

Place the Base on stable ground with a clear sky view and suitable protection from site activity.

 

Cause 4: Base and Rover Frequency Do Not Match

 

For UHF Base and Rover operation, both units must use compatible frequency settings.

 

Check:

 

Frequency

 

Channel

 

Channel spacing

 

Regional configuration

 

If the Base transmits on one channel and the Rover listens on another, no correction data will be received.

 

Cause 5: Radio Protocol Does Not Match

 

Matching frequency alone is not enough.

 

The Base and Rover must also use a compatible radio protocol.

 

The TOKNAV T10 Pro specifications list support for protocols including:

 

TRIMTALK

 

TRIMMK3

 

SOUTH

 

TRANSEOT

 

If the protocols do not match, the Rover may detect radio activity but fail to decode the corrections.

 

Cause 6: Air Baud Rate or Correction Format Is Wrong

 

Base and Rover settings may also require compatible:

 

Air baud rate

 

Correction-data format

 

Base identification

 

Data link configuration

 

A mismatch can prevent usable correction reception.

 

Compare all radio settings rather than checking only the displayed channel number.

 

Cause 7: UHF Antenna Problem

 

Inspect the Base and Rover radio antennas.

 

Check for:

 

Missing antenna

 

Wrong antenna type

 

Loose connection

 

Bent connector

 

Damaged cable

 

Cracked housing

 

Corrosion

 

Incorrect adapter

 

Antenna installed on the wrong port

 

Never transmit at high power without the correct antenna properly connected.

 

Cause 8: Base Antenna Is Too Low

 

A low Base-radio antenna may be blocked by:

 

Vehicles

 

Soil piles

 

Barriers

 

Workers

 

Machinery

 

Buildings

 

Small terrain changes

 

Where safe and suitable, raising the Base antenna can improve the UHF path.

 

A lower-power radio with a well-positioned antenna may perform better than a higher-power radio placed behind an obstruction.

 

Cause 9: Terrain Blocks the UHF Signal

 

Hills, cuttings and embankments can block the direct radio path.

 

This is especially common on:

 

Road projects

 

Pipeline routes

 

Plantation sites

 

Quarries

 

Hilly developments

 

Long drainage projects

 

The Rover may work near the Base but lose corrections after moving behind a hill.

 

Possible solutions include:

 

Repositioning the Base

 

Increasing safe antenna height

 

Using a compatible repeater

 

Changing to network RTK

 

Dividing the project into separate setups

 

Cause 10: Rover Is Too Far from the Base

 

A longer Base-to-Rover distance may affect:

 

UHF reception

 

Atmospheric-error similarity

 

Initialization time

 

RTK reliability

 

The practical distance depends on:

 

Radio power

 

Antenna height

 

Terrain

 

Buildings

 

Vegetation

 

Interference

 

Frequency

 

Satellite conditions

 

Do not assume the same working range will be available on every site.

 

Cause 11: Radio Interference

 

Other equipment may interfere with the selected UHF channel.

 

Possible sources include:

 

Other survey crews

 

Industrial radio systems

 

Site communications

 

Electrical equipment

 

Nearby transmitters

 

High-voltage infrastructure

 

Where permitted, test another compatible channel and compare performance.

 

Record the original settings before making changes.

 

Cause 12: TBase Is Not Actually Transmitting

 

Satellite tracking does not automatically mean the TBase is broadcasting corrections.

 

Confirm:

 

Receiver is in Base mode

 

Base coordinates are entered

 

UHF transmission is enabled

 

Transmission indicator is active

 

Correct antenna is connected

 

Radio power is selected

 

Battery is sufficient

 

Correction data is being generated

 

Test the Rover at a short distance from the Base.

 

If it still receives nothing, focus on configuration or hardware rather than range.

 

Cause 13: Weak Mobile-Data Coverage

 

When using CORS, VRS or NTRIP corrections, the controller requires reliable mobile data.

 

Problems may include:

 

Weak signal

 

Congested network

 

Unsupported mobile band

 

No data balance

 

SIM-card issue

 

Incorrect APN

 

Roaming restriction

 

Temporary telecommunications outage

 

A controller may show mobile signal while still lacking a usable internet connection.

 

Test access to the correction server rather than relying only on the signal bars.

 

Cause 14: Incorrect NTRIP Information

 

Check the:

 

Server address

 

Port number

 

Username

 

Password

 

Mountpoint

 

Correction format

 

NTRIP information must normally be entered exactly as supplied.

 

Common mistakes include:

 

Additional spaces

 

Capital-letter differences

 

Wrong mountpoint

 

Expired password

 

Incorrect port

 

Old account details

 

Cause 15: Correction-Service Account Problem

 

The network account may be:

 

Expired

 

Suspended

 

Logged in on another device

 

Restricted to one simultaneous connection

 

Outside its permitted region

 

Not authorised for the selected mountpoint

 

Confirm the account status with the service provider.

 

Cause 16: Selected Mountpoint Is Unsuitable

 

A mountpoint may differ by:

 

Reference station

 

Correction format

 

Network solution

 

Coverage area

 

Coordinate reference

 

Required Rover-position message

 

Select the mountpoint recommended for the receiver and project area.

 

The closest-looking name is not always the correct choice.

 

Cause 17: Rover Position Is Not Being Sent to the Network

 

Some network RTK services require the Rover’s approximate position to generate a VRS or appropriate correction stream.

 

If the position message is not transmitted correctly, the service may fail to provide usable corrections.

 

Check the NTRIP and software configuration.

 

Cause 18: Base-to-Rover Distance Is Excessive

 

Even if corrections are received, a very long distance from the reference station may make ambiguity resolution slower or less reliable.

 

This applies to:

 

Local Base operation

 

Single-station network corrections

 

Distant CORS stations

 

Use a suitable closer reference source or network solution where available.

 

Cause 19: Receiver Has Not Had Time to Reinitialize

 

After:

 

Moving through an obstructed area

 

Losing corrections

 

Restarting the receiver

 

Changing correction sources

 

Passing beneath a bridge

 

Working close to buildings

 

the receiver may require time under open sky to return to Fixed.

 

Stand still in a suitable location and allow the solution to stabilize.

 

Repeatedly walking or moving the pole during initialization may delay the process.

 

Cause 20: Receiver Configuration Is Incorrect

 

Review:

 

Rover mode

 

Base mode

 

Correction source

 

UHF receive mode

 

Network mode

 

Satellite settings

 

Elevation mask

 

Data-link settings

 

Firmware compatibility

 

Software version

 

Do not load an unknown configuration file without understanding its settings.

 

Cause 21: Firmware or Software Compatibility

 

Communication problems may occur if:

 

Receiver firmware is outdated

 

Controller application is incompatible

 

Base and Rover firmware differ significantly

 

Required drivers or protocols are unavailable

 

tSurvey configuration is incomplete

 

Record the current versions before performing updates.

 

Use only approved firmware and follow the supplier’s procedure.

 

Cause 22: Hardware Damage

 

Possible hardware issues include:

 

Damaged GNSS antenna

 

Damaged UHF module

 

Water ingress

 

Impact damage

 

Loose connector

 

Battery instability

 

Faulty cable

 

Defective external antenna

 

Compare the receiver with another known-working unit where possible.

 

A controlled open-sky test helps distinguish hardware problems from difficult site conditions.

 

Fast Troubleshooting Sequence

 

If the TOKNAV Rover remains Float:

 

Move to open sky.

 

Hold the pole stationary.

 

Check whether corrections are being received.

 

Monitor correction-data age.

 

Confirm Rover mode.

 

Check the Base or NTRIP connection.

 

Test near the Base if using UHF.

 

Match frequency and protocol.

 

Inspect the antennas.

 

Restart the correction connection.

 

Compare another open location.

 

Test another correction source if available.

 

Record screenshots and settings.

 

Contact technical support if the problem remains.

 

UHF Base and Rover Troubleshooting

 

Step 1: Test at Short Distance

 

Place the Rover near the TBase.

 

If it receives corrections at short distance, the configuration is probably close to correct, and the problem may involve range, terrain or antenna placement.

 

If it receives nothing, check:

 

Frequency

 

Protocol

 

Correction format

 

Base transmission

 

Antennas

 

Receiver modes

 

Step 2: Confirm TBase Mode

 

Verify that the TBase is configured as a Base rather than Rover or static receiver.

 

Step 3: Match Radio Settings

 

Compare the settings side by side.

 

Step 4: Inspect Antennas

 

Make sure the correct antennas are installed securely.

 

Step 5: Raise the Base Antenna

 

Improve line of sight where this can be done safely.

 

Step 6: Test in Open Terrain

 

A successful open-area test indicates that the original site is affecting communication or GNSS performance.

 

Network RTK Troubleshooting

 

Step 1: Check Internet Access

 

Confirm that the controller has a working data connection.

 

Step 2: Verify NTRIP Details

 

Re-enter the server, port, username, password and mountpoint carefully.

 

Step 3: Check Account Status

 

Confirm that the service is active and allows the connection.

 

Step 4: Monitor Incoming Data

 

Look for received correction-data indicators and a low correction age.

 

Step 5: Change Location

 

Move to an open area with stronger mobile and satellite reception.

 

Step 6: Test Another Mountpoint

 

Only select another mountpoint when it is approved and suitable for the project.

 

Step 7: Compare Another Network

 

Where available, compare another mobile hotspot or correction source.

 

Fixed-to-Float Near Buildings

 

If the receiver becomes Fixed in an open field but changes to Float near a building, the likely causes include:

 

Blocked satellites

 

Multipath

 

Poor satellite geometry

 

Interrupted radio signal

 

Building interference

 

Possible actions include:

 

Move farther from the structure

 

Increase observation time

 

Use an offset point

 

Use IMU tilt from a more open position

 

Use T50 laser measurement where suitable

 

Use a Total Station

 

Do not force GNSS use where the environment is unsuitable.

 

Fixed-to-Float Under Trees

 

Tree trunks, branches and wet leaves can weaken or disturb GNSS signals.

 

Performance can change according to:

 

Canopy density

 

Moisture

 

Satellite positions

 

Time of day

 

Receiver location

 

Base quality

 

Moving a short distance into a clearer area may produce a significant improvement.

 

Measure the required point using a suitable offset or another instrument if direct GNSS observation is unreliable.

 

Should a Float Position Be Stored?

 

For centimetre-level survey and stakeout work, Float observations should generally not be accepted automatically.

 

Before storing a Float point, consider:

 

Project tolerance

 

Purpose of the measurement

 

Estimated precision

 

Site conditions

 

Availability of another method

 

Whether the result can be checked

 

Client requirements

 

A coordinate appearing stable on the screen does not mean it meets the project accuracy.

 

Information to Record for Technical Support

 

Provide:

 

Receiver model

 

Base and Rover serial numbers where required

 

Controller model

 

Software version

 

Firmware version

 

Correction method

 

UHF settings

 

NTRIP details excluding passwords

 

Correction-data age

 

Satellite status

 

Fixed or Float status

 

Base-to-Rover distance

 

Site photographs

 

Screenshots

 

Time and location of the problem

 

Results from an open-sky test

 

Do not send account passwords in ordinary troubleshooting messages.

 

Preventing Float Problems

 

Before going to the site:

 

Charge all equipment

 

Confirm software licences

 

Test Base and Rover communication

 

Verify NTRIP credentials

 

Inspect antennas

 

Prepare a backup correction method

 

Save approved settings

 

Check mobile coverage

 

Update firmware only when necessary and tested

 

At the site:

 

Install the Base in open sky

 

Raise the radio antenna where appropriate

 

Monitor correction age

 

Avoid measuring beside reflective structures

 

Confirm Fixed status

 

Recheck known control

 

Record recurring problem locations

 

TOKNAV RTK Fixed and Float Troubleshooting Malaysia

 

Contact MTM Precision for the TOKNAV T50, T10 Pro, TBase, PCR100T and tSurvey software, including UHF configuration, network RTK setup, Fixed and Float troubleshooting, demonstration and technical discussion in Malaysia.

 

MTM Precision Sdn. Bhd. (744811-A)

 

Telephone: +603-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my

Website: www.mtmpre.com.my

 

Showroom & Service Centre:

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.


 

18 Sep 2026