TOKNAV RTK Pole Height and Antenna Height Setup Malaysia

TOKNAV RTK Pole Height and Antenna Height Setup Malaysia

 

Correct pole height and antenna height are essential when using a TOKNAV T50, T10 Pro or TBase for RTK surveying.

 

An incorrect height entry can produce a systematic elevation error even when the receiver:

 

Shows a stable Fixed solution

 

Has good satellite reception

 

Receives valid corrections

 

Repeatedly measures the same coordinate

 

Operates within the published RTK specifications

 

This guide explains the difference between Rover pole height, Base antenna height, vertical height and slant height for surveying work in Malaysia.

 

Why Height Setup Matters

 

The GNSS receiver calculates the position of its antenna reference point.

 

However, the point required by the surveyor is normally:

 

The ground point below the Rover pole

 

The known control point beneath the Base

 

A benchmark

 

A setting-out point

 

A topographic feature

 

The software applies the entered antenna or pole height to calculate the coordinate of the required ground point.

 

If the entered value is wrong, the calculated elevation will also be wrong.

 

Simple Example

 

Suppose the Rover pole is physically set to 2.000m, but the controller is set to 1.800m.

 

The 0.200m difference can introduce an elevation error of approximately 0.200m, depending on the software’s measurement convention and setup.

 

The receiver may still show Fixed because Fixed status does not verify the pole-height entry.

 

Three Heights That Must Not Be Confused

 

Rover Pole Height

 

The distance from the survey point at the bottom of the pole to the receiver’s specified antenna reference.

 

Base Antenna Height

 

The distance from the known Base control mark to the specified reference point on the Base receiver or antenna.

 

Target or Design Height

 

A project elevation, offset or construction level used for checking or stakeout.

 

These are different values and should be recorded separately.

 

Vertical Height Versus Slant Height

 

Vertical Height

 

Measured vertically from the ground or control point to the antenna reference point.

 

Slant Height

 

Measured diagonally from the ground mark to a specified point on the antenna or receiver.

 

These values are not interchangeable.

 

If the software expects vertical height but the operator enters a slant measurement directly, the resulting Base elevation may be incorrect.

 

Confirm:

 

Which height type was physically measured

 

Which reference point was used

 

Which height type the software expects

 

Whether the software performs a conversion

 

Antenna Reference Point

 

The height must be measured to the correct receiver reference.

 

Possible reference definitions include:

 

Antenna Reference Point

 

Antenna Phase Centre

 

Bottom of receiver

 

Mounting point

 

Specified measurement mark

 

Slant-height mark

 

Do not assume the top or bottom of the receiver is automatically the correct reference.

 

Use the receiver documentation and the matching antenna type selected in the software.

 

Rover Pole Height Setup

 

A Rover pole may have fixed or adjustable positions such as:

 

1.800m

 

2.000m

 

2.200m

 

Another marked height

 

Before measuring:

 

Extend the pole to the required position.

 

Confirm the correct graduation mark.

 

Lock every pole section.

 

Check that the receiver is mounted securely.

 

Enter the corresponding height into tSurvey.

 

Confirm the unit.

 

Measure a known point.

 

Do not rely only on memory from the previous project.

 

Common Rover Pole-Height Mistakes

 

Pole is set to 2.000m but software shows 1.800m

 

Pole is extended during the survey without updating the controller

 

Metres and feet are confused

 

Wrong receiver profile is selected

 

Height is measured to the wrong receiver point

 

Pole section is not fully locked

 

Receiver adapter adds unrecorded height

 

A mini pole is used with the previous full-pole setting

 

Old project settings are reused

 

Staff member assumes a standard height without checking

 

Base Antenna Height Setup

 

The TBase may be installed:

 

Directly over known control

 

On a tripod and tribrach

 

On a fixed pillar

 

On another stable survey mount

 

The operator must determine the relationship between the control point and the receiver’s defined antenna reference.

 

A complete Base record should include:

 

Base point name

 

Easting

 

Northing

 

Elevation

 

Antenna-height value

 

Height type

 

Receiver or antenna model

 

Setup date and time

 

Operator

 

Photograph of the setup

 

Measuring Base Vertical Height

 

If a true vertical measurement can be made:

 

Identify the ground control mark.

 

Identify the receiver’s specified reference point.

 

Measure the vertical distance between them.

 

Repeat the measurement.

 

Record the value and unit.

 

Enter it using the correct height type.

 

Make sure the tape or measuring device is not angled unintentionally.

 

Measuring Base Slant Height

 

A slant height may be easier to measure when the receiver is mounted on a tripod.

 

However, it must be measured to the correct specified mark.

 

Before using slant height, confirm:

 

The receiver supports the method

 

The correct slant reference is known

 

The software has the correct antenna model

 

The software expects slant rather than vertical height

 

Any conversion is performed correctly

 

Do not manually invent a conversion without the necessary receiver dimensions.

 

Base Antenna Height and Rover Results

 

An incorrect Base antenna height commonly affects the elevation relationship of the survey.

 

For example, if the Base antenna height is entered incorrectly by 0.100m, Rover elevations may also contain a related systematic error.

 

The exact result depends on:

 

How the Base coordinate was defined

 

Whether the entered Base coordinate refers to the ground mark or antenna

 

The software workflow

 

Whether the Base position is fixed or averaged

 

The correction and processing method

 

For critical work, test the complete system against an independent benchmark.

 

Base Coordinate Versus Base Antenna Coordinate

 

The operator must know whether the entered coordinate belongs to:

 

The ground control point

 

The receiver antenna

 

A previously calculated Base position

 

An autonomous GNSS position

 

A temporary site coordinate

 

Entering a ground-mark coordinate as though it belongs to the antenna can create a height error.

 

Entering an antenna coordinate and then applying antenna height again may duplicate the correction.

 

The workflow must be clear before the Base is started.

 

Pole Height with IMU Tilt

 

The T50 and T10 Pro support IMU tilt measurement up to approximately 60°.

 

The software uses the pole height together with the measured orientation to calculate the pole-tip coordinate.

 

This means an incorrect pole height can create both:

 

Vertical error

 

Horizontal error when the pole is tilted

 

The larger the tilt angle, the more noticeable the horizontal effect may become.

 

Before using IMU tilt:

 

Confirm the pole height

 

Lock the pole sections

 

Initialize the IMU

 

Keep the pole tip fixed

 

Use the smallest practical tilt

 

Compare with a vertical observation

 

Pole Height with T50 Laser Measurement

 

The T50 green-laser workflow differs from direct pole-tip measurement.

 

Depending on the software workflow, the system uses the receiver position, orientation and laser distance to calculate the remote target coordinate.

 

Do not apply a conventional Rover pole-height assumption to a laser workflow without following the T50 operating procedure.

 

Before field use, demonstrate:

 

Direct pole measurement

 

IMU tilt measurement

 

Green-laser measurement

 

Compare all three against a known target.

 

Checking Pole Height on a Known Point

 

A practical check is:

 

Select an approved control point.

 

Enter the intended pole height.

 

Obtain a stable Fixed solution.

 

Measure the point vertically.

 

Compare the measured elevation with the accepted value.

 

Recheck the physical pole.

 

Repeat the observation.

 

Document the difference.

 

If the horizontal coordinate matches but the elevation differs by a value close to the height-setting error, inspect the pole and antenna-height entries first.

 

Testing Two Pole Heights

 

Another useful test is to measure the same point using two accurately known pole heights.

 

For example:

 

Measure the point at 2.000m.

 

Change the physical pole to 1.800m.

 

Update the software to 1.800m.

 

Measure the same point again.

 

Compare the calculated ground coordinates.

 

If the setup is correct, both measurements should represent the same ground point within the demonstrated measurement tolerance.

 

If the second software height is not updated, the elevation difference will reveal the mistake.

 

Pole-Height Error Patterns

 

Observed ProblemPossible CauseElevation wrong by a constant amountRover pole height or Base antenna heightHorizontal correct but elevation wrongHeight entry, geoid or vertical datumVertical reading correct but tilted reading wrongPole height, tip movement or IMUEvery Rover has the same height errorBase setup or project vertical referenceOne Rover only has the errorRover pole height or receiver profileError began after changing the poleSoftware height not updatedError changes with tilt anglePole height, pole geometry or IMUBase setup gives different elevations each dayBase height measurement or setup inconsistency

 

These patterns should be confirmed through field testing.

 

Do Not Confuse Pole Height with Benchmark Elevation

 

A benchmark elevation describes the level of the ground control mark.

 

Pole height describes the physical distance from the mark to the receiver.

 

For example:

 

Benchmark elevation: 52.348m

 

Rover pole height: 2.000m

 

These values serve completely different purposes.

 

Do not add or subtract them manually unless the approved survey workflow specifically requires it.

 

Units Must Match

 

Check whether the project uses:

 

Metres

 

Millimetres

 

Feet

 

International feet

 

Another specified unit

 

Common errors include:

 

Entering 2000 when software expects metres

 

Entering 2.000 when software expects millimetres

 

Reading a pole graduation in feet

 

Importing a design file with different units

 

Mixing metric and imperial accessories

 

A unit error can produce a much larger problem than the RTK instrument’s published accuracy.

 

Pole Bubble and Vertical Measurement

 

For conventional measurements, the pole must be held vertically.

 

Check the pole bubble before relying on it.

 

A damaged or incorrectly adjusted bubble may cause the pole to lean even when the operator believes it is vertical.

 

Inspect:

 

Bubble-centre position

 

Pole straightness

 

Locking sections

 

Pointed tip

 

Receiver mount

 

Compare the bubble against another verified method where appropriate.

 

Pole Straightness

 

A bent pole changes the relationship between the receiver and ground point.

 

Check for:

 

Visible bending

 

Loose sections

 

Damaged threads

 

Worn clamps

 

Receiver wobble

 

Misaligned tip

 

Rotate the pole while observing whether the receiver or tip moves around the vertical axis.

 

Replace or service a damaged pole before precision use.

 

Adapter and Accessory Height

 

Accessories may change the total height, including:

 

Quick-release adapter

 

Special receiver mount

 

Pole extension

 

Tribrach adapter

 

Base spacer

 

External antenna mount

 

Record the complete assembled height rather than assuming the pole marking alone represents the final antenna height.

 

Use the manufacturer’s specified measurement convention.

 

Base Tripod Movement

 

Even with the correct antenna height, results can be affected if the Base setup moves.

 

Possible causes include:

 

Tripod settling into soft soil

 

Loose tripod clamps

 

Vehicle vibration

 

Accidental impact

 

Wind

 

Unstable platform

 

Heat-related movement

 

Construction activity

 

Inspect the Base throughout long survey sessions.

 

If it has moved, stop work and evaluate the affected observations.

 

Incorrect Pole Height During Stakeout

 

A wrong pole height may produce incorrect cut-and-fill or elevation guidance during:

 

Formation checks

 

Road stakeout

 

Drain-level work

 

Platform construction

 

Pipe installation

 

Earthwork grids

 

Horizontal stakeout may appear correct while the displayed design-level difference is wrong.

 

Verify the pole height before marking cut or fill on a peg.

 

Incorrect Height During Topographic Survey

 

A pole-height mistake during a topographic survey can shift the recorded elevations of:

 

Ground points

 

Drain inverts

 

Road levels

 

Manholes

 

Platform levels

 

Breaklines

 

Contours

 

If the error affects an entire dataset, correction may be possible only when:

 

The exact wrong value is known

 

The physical pole height is confirmed

 

The height remained unchanged

 

Raw data and metadata are preserved

 

The processing method permits correction

 

Do not change completed survey data without documenting the correction.

 

Daily Height-Setup Checklist

 

Before the survey:

 

Inspect the Rover pole

 

Confirm the physical pole height

 

Tighten every pole section

 

Check the receiver mounting

 

Verify the project units

 

Enter the correct Rover height

 

Confirm the Base height type

 

Measure the Base antenna height

 

Record the Base setup

 

Check a known point

 

During the survey:

 

Recheck the pole after adjustment

 

Update the software when the height changes

 

Monitor whether another operator changes the pole

 

Check the Base for movement

 

Repeat important elevations

 

Record special adapters

 

After the survey:

 

Measure an independent check point

 

Save the final pole-height record

 

Export the raw observations

 

Photograph the Base before dismantling

 

Document any height changes

 

Recommended Field Record

 

ItemValueProjectDateOperatorRover modelRover pole heightHeight unitBase modelBase pointBase coordinateBase antenna heightHeight typeVertical / SlantAntenna referenceAdapter usedCheck-point resultRemarks

 

This record is valuable if a height discrepancy is discovered later.

 

Troubleshooting Height Differences

 

If an elevation appears wrong:

 

Stop the affected work.

 

Measure an approved benchmark.

 

Check the physical Rover pole height.

 

Check the controller height entry.

 

Confirm the units.

 

Inspect the pole and receiver mount.

 

Review the Base antenna height.

 

Confirm the Base-coordinate definition.

 

Check the geoid and vertical datum.

 

Repeat without IMU tilt.

 

Compare another Rover if available.

 

Record all differences before changing settings.

 

Do not change several parameters simultaneously, because this makes the original cause difficult to identify.

 

Pole Height Error Versus Geoid Error

 

Both can cause incorrect elevations, but the pattern may differ.

 

Pole-Height Error

 

Often affects one Rover, one setup or observations collected after the pole was adjusted.

 

Base Antenna-Height Error

 

May affect all Rovers using the same local Base setup.

 

Geoid or Vertical-Datum Error

 

May affect the entire project or network RTK workflow, even when physical heights are correct.

 

Use independent benchmarks and setup records to identify the source.

 

Questions Before Starting Work

 

Ask:

 

What coordinate system does the project use?

 

What vertical datum is required?

 

Is the Base coordinate for the ground point or antenna?

 

Is the Base height vertical or slant?

 

What reference point does the receiver use?

 

What Rover pole height is entered?

 

Are any adapters installed?

 

Are the units metres or feet?

 

Has the system been checked on a benchmark?

 

Will the pole height change during the work?

 

TOKNAV RTK Height Setup Support in Malaysia

 

Contact MTM Precision for the TOKNAV T50, T10 Pro, TBase, PCR100T and tSurvey software, including Rover pole-height setup, Base antenna-height configuration, known-point verification, training and technical discussion in Malaysia.

 

MTM Precision Sdn. Bhd. (744811-A)

 

Telephone: +603-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my

Website: www.mtmpre.com.my

 

Showroom & Service Centre:

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.


 

18 Sep 2026