TOKNAV RTK IMU Tilt Measurement Troubleshooting Malaysia

TOKNAV RTK IMU Tilt Measurement Troubleshooting Malaysia

 

The TOKNAV T50 and T10 Pro support IMU tilt measurement up to approximately 60°, allowing the survey pole to be held at an angle while the pole tip remains on the required point.

 

This can improve access beside walls, drains, barriers, vehicles, construction materials and other obstructions.

 

However, if the IMU is not initialized correctly, the pole tip moves or the project configuration is wrong, tilted observations may differ from vertical-pole measurements.

 

This guide explains how to check and troubleshoot TOKNAV RTK IMU tilt measurement in Malaysia.

 

What Does IMU Tilt Measurement Do?

 

During conventional RTK measurement, the survey pole is held vertically above the point.

 

With IMU tilt compensation:

 

The pole tip stays on the survey point

 

The receiver is held at an angle

 

The IMU determines the pole orientation

 

The software calculates the coordinate of the pole tip

 

This allows the antenna to remain away from an obstruction while the pole tip occupies the required point.

 

IMU tilt does not allow the pole tip to be placed somewhere other than the survey point.

 

TOKNAV IMU Tilt Specifications

 

The published specifications include:

 

TOKNAV T50

 

Tilt range: Up to approximately 60°

 

Tilt accuracy: Less than 2cm below 60°

 

RTK horizontal accuracy: ±(8 mm + 1 ppm)

 

RTK vertical accuracy: ±(15 mm + 1 ppm)

 

TOKNAV T10 Pro

 

Tilt range: Up to 60°

 

Tilt accuracy: ≤2cm within 60°

 

RTK horizontal accuracy: ±(8 mm + 1 ppm)

 

RTK vertical accuracy: ±(15 mm + 1 ppm)

 

Published figures apply under the manufacturer’s specified conditions.

 

Actual results depend on RTK quality, tilt angle, pole stability, initialization, receiver firmware and operator technique.

 

Suitable IMU Tilt Applications

 

IMU tilt may help when measuring:

 

Building corners

 

Wall edges

 

Fence points

 

Road shoulders

 

Drain edges

 

Manhole features

 

Utility points

 

Points beside vehicles

 

Points under vegetation

 

Points obstructed by materials

 

Excavation edges

 

Retaining-wall features

 

It is intended to make direct pole-tip occupation more practical.

 

IMU Tilt Versus T50 Green Laser

 

These functions solve different problems.

 

IMU Tilt

 

Use when the pole tip can reach and touch the required point, but the pole cannot be held vertically.

 

T50 Green Laser

 

Use when the pole tip cannot reach the point, but the target is visible and suitable for laser measurement.

 

Tilting the pole does not convert the receiver into a remote-measurement instrument.

 

Common Signs of an IMU Problem

 

Possible warning signs include:

 

Tilt result differs significantly from vertical measurement

 

Coordinate changes as the pole rotates

 

Position moves while the pole tip remains fixed

 

IMU status remains inactive

 

Software requests repeated initialization

 

Tilt value does not respond correctly

 

Results are inconsistent in different directions

 

Large differences appear at higher tilt angles

 

Measurement is stable vertically but unstable when tilted

 

Receiver loses Fixed status during the workflow

 

These symptoms may involve the IMU, GNSS conditions, software setup or operating technique.

 

Cause 1: IMU Is Not Initialized

 

The IMU may require an initialization movement or procedure before tilt compensation becomes active.

 

Depending on the software and firmware, the operator may need to:

 

Move the pole in the specified way

 

Walk a short distance

 

Rotate or swing the receiver

 

Wait for an IMU-ready indication

 

Restart the tilt function

 

Follow the procedure supplied for the actual receiver and software version.

 

Do not assume tilt compensation is active merely because the pole is angled.

 

Cause 2: Poor RTK Solution

 

The IMU calculates the pole-tip position using the receiver’s GNSS position and orientation.

 

If the Rover is:

 

Single

 

Float

 

Receiving intermittent corrections

 

Experiencing high correction-data age

 

Working in severe multipath

 

the final tilted coordinate may be unreliable.

 

Obtain a stable Fixed solution before evaluating IMU performance.

 

Cause 3: Pole Tip Moves

 

The most common operating error is movement at the pole tip.

 

While the receiver is tilted or rotated, the tip must remain fixed on the exact point.

 

Movement can occur on:

 

Smooth concrete

 

Wet surfaces

 

Loose soil

 

Stones

 

Metal covers

 

Slopes

 

Rounded objects

 

Vegetation

 

Soft ground

 

Use a stable point and avoid excessive pole movement during the observation.

 

Cause 4: Incorrect Pole Height

 

IMU compensation requires the correct pole height.

 

If the physical pole is set to 2.000m but the controller uses 1.800m, the calculated pole-tip coordinate will be wrong.

 

Check:

 

Physical pole height

 

Software pole-height value

 

Units

 

Antenna reference

 

Pole extension locks

 

Whether the pole changed during the survey

 

The effect of an incorrect height can become more noticeable when the pole is tilted.

 

Cause 5: Excessive Tilt Angle

 

The T50 and T10 Pro specify a tilt range up to approximately 60°.

 

Do not exceed the stated range.

 

Even within the supported range:

 

A larger angle makes the pole harder to control

 

Tip movement becomes more likely

 

Pole-height errors have greater horizontal influence

 

Obstructions may affect GNSS reception

 

Operator movement may become more significant

 

Use the smallest practical tilt angle.

 

Cause 6: Pole Is Bent or Loose

 

Inspect the survey pole for:

 

Bent sections

 

Loose locking mechanisms

 

Worn threads

 

Receiver movement

 

Damaged tip

 

Incorrect adapter

 

Unstable extension

 

Play between sections

 

A damaged or loose pole changes the assumed geometry between the receiver and pole tip.

 

Cause 7: Receiver Is Not Mounted Securely

 

The receiver must be firmly attached to the pole.

 

Check:

 

Thread connection

 

Adapter

 

Locking mechanism

 

Receiver orientation

 

Pole mount

 

Any movement between components

 

A loose receiver can move independently of the pole and affect the calculated orientation.

 

Cause 8: GNSS Obstruction During Tilt

 

Tilting the pole may move the receiver closer to:

 

A wall

 

Vehicle

 

Fence

 

Roof

 

Tree

 

Metal structure

 

Retaining wall

 

The tilted position may have worse satellite visibility than the vertical position.

 

If the result changes only when the receiver is moved close to an obstruction, investigate multipath and blocked signals.

 

Cause 9: IMU Status Was Lost

 

The IMU may need reinitialization after:

 

Receiver restart

 

Software restart

 

Long period without movement

 

Sudden impact

 

Severe pole movement

 

Firmware update

 

Connection interruption

 

Switching projects

 

Changing receiver modes

 

Monitor the software’s IMU status rather than assuming the previous initialization remains valid.

 

Cause 10: Software or Firmware Problem

 

Tilt behaviour can be affected by:

 

Outdated receiver firmware

 

Incompatible tSurvey version

 

Incomplete software activation

 

Incorrect receiver profile

 

Failed configuration

 

Communication problem between controller and receiver

 

Record the existing versions before updating anything.

 

Use the manufacturer’s approved firmware and upgrade procedure.

 

Cause 11: Magnetic or Environmental Influence

 

An IMU may contain several motion and orientation sensors.

 

Strong environmental influences may affect some workflows, including proximity to:

 

Heavy machinery

 

Large steel structures

 

Vehicles

 

Strong electrical equipment

 

Magnetic sources

 

Move to a clear area and repeat the initialization and test.

 

Do not assume every inconsistency is caused by magnetic interference; verify through comparison.

 

Cause 12: Wrong Coordinate or Project Setup

 

IMU compensation cannot correct:

 

Wrong Base coordinates

 

Wrong datum

 

Wrong projection

 

Incorrect localization

 

Wrong geoid

 

Incorrect project units

 

If both vertical and tilted observations are shifted by a similar amount, investigate the project setup rather than the IMU.

 

Vertical-versus-Tilt Test

 

A practical field test is to measure the same known point several ways.

 

Step 1: Select a Suitable Test Point

 

Choose a stable, clearly defined point in open sky.

 

Step 2: Confirm Fixed Status

 

Check that the Rover has stable corrections and a low correction age.

 

Step 3: Enter the Correct Pole Height

 

Measure and confirm the physical pole height.

 

Step 4: Measure Vertically

 

Hold the pole vertical and store the point.

 

Repeat the vertical observation at least twice.

 

Step 5: Initialize the IMU

 

Follow the required TOKNAV and tSurvey procedure until the software shows that tilt compensation is ready.

 

Step 6: Tilt in One Direction

 

Keep the tip fixed and measure the point with the pole tilted.

 

Step 7: Tilt in Other Directions

 

Repeat with the pole tilted in several directions.

 

Step 8: Compare the Coordinates

 

Compare:

 

Easting

 

Northing

 

Elevation

 

Horizontal difference

 

Vertical difference

 

Repeatability

 

A large directional difference may indicate tip movement, pole geometry, GNSS obstruction or an IMU issue.

 

Four-Direction IMU Check

 

A useful test is to tilt the pole:

 

North

 

East

 

South

 

West

 

The tip remains on the same point for every measurement.

 

If all tilted observations cluster close to the vertical result, the IMU behaviour is likely consistent under those conditions.

 

If one direction produces a larger error, check whether the receiver moved closer to a wall, vehicle or other reflective surface.

 

Rotate Around the Pole Tip Carefully

 

Some field checks involve rotating the receiver around a fixed pole tip.

 

During this process:

 

Keep the tip in exactly the same position

 

Avoid sliding

 

Do not lift the tip

 

Keep the pole height unchanged

 

Use moderate movements

 

Wait for the reading to stabilize

 

Aggressive rotation can create more error than it diagnoses.

 

Testing Different Tilt Angles

 

Compare observations at approximately:

 

Vertical

 

Small tilt

 

Moderate tilt

 

Larger tilt within the supported range

 

If the error grows rapidly with the angle, inspect:

 

Pole-height setting

 

Pole straightness

 

Tip stability

 

Receiver mounting

 

IMU initialization

 

Multipath

 

Use the minimum tilt needed to clear the obstruction.

 

IMU Tilt Near a Wall

 

When measuring beside a wall:

 

Place the pole tip on the exact target.

 

Tilt the receiver away from the wall.

 

Confirm that the receiver has a clearer sky view.

 

Check Fixed status.

 

Wait for a stable reading.

 

Store and repeat the point.

 

Compare with another observation if possible.

 

Tilting toward the wall may worsen multipath and satellite obstruction.

 

IMU Tilt at Drain Edges

 

IMU tilt can help when:

 

The point is reachable

 

The pole tip can touch the drain feature

 

The operator cannot hold the pole vertically

 

The receiver must remain away from the drain wall

 

Do not stretch into an unsafe position merely to place the pole tip.

 

Use the T50 laser function or another suitable method if the point cannot be reached safely.

 

IMU Tilt for Building Corners

 

At a building corner, the pole tip may reach the point while the receiver is obstructed by the wall.

 

Tilting the receiver away from the structure can improve accessibility.

 

However, verify:

 

Exact corner identification

 

Stable tip placement

 

RTK status

 

Multipath

 

Repeated result

 

For precision structural setting out, a Total Station may still be more appropriate.

 

Elevation Checks with Tilt Measurement

 

Horizontal position often receives the most attention, but elevation must also be checked.

 

Compare:

 

Vertical-pole elevation

 

Tilted-pole elevation

 

Known benchmark level

 

Repeated observations

 

Elevation differences may result from:

 

Wrong pole height

 

Unstable tip

 

Poor GNSS vertical solution

 

Wrong geoid

 

Wrong vertical datum

 

Base antenna-height error

 

Do not attribute every height discrepancy to the IMU.

 

IMU Troubleshooting Sequence

 

If tilt measurements are inconsistent:

 

Stop using the questionable tilted results.

 

Move to an open area.

 

Obtain a stable Fixed solution.

 

Check correction-data age.

 

Confirm the pole height.

 

Inspect the pole and receiver mounting.

 

Measure the point vertically.

 

Reinitialize the IMU.

 

Repeat at a small tilt angle.

 

Test several directions.

 

Restart the receiver and controller if necessary.

 

Record screenshots and results.

 

Compare another pole or receiver where available.

 

Contact technical support if the problem remains.

 

When to Use a Vertical Pole Instead

 

Use a conventional vertical-pole measurement when:

 

The point is accessible

 

The pole can be held correctly

 

Critical accuracy is required

 

IMU status is uncertain

 

The operator cannot stabilize the tip

 

The receiver is close to strong obstructions

 

The tilted observation fails the comparison check

 

IMU tilt is a useful option, not a requirement for every measurement.

 

When to Use the T50 Laser Instead

 

Consider the T50 green laser when:

 

The pole tip cannot reach the point

 

Direct access is unsafe

 

A trench, drain or fence prevents occupation

 

The target is visible

 

The surface is suitable for laser measurement

 

The required tolerance permits the method

 

The published laser 3D positioning error is ≤2.5cm within 5m under the stated conditions.

 

Laser measurement and IMU tilt should not be treated as interchangeable.

 

When to Use a Total Station

 

A Total Station may be preferable when:

 

GNSS signals are obstructed

 

Work is indoors

 

Structural tolerances are tight

 

Precise alignment is required

 

Points are below a roof or bridge

 

Multipath is severe

 

Independent verification is needed

 

Many projects use RTK for broad external control and a Total Station for precise structural work.

 

Information to Send for Technical Support

 

Provide:

 

Receiver model

 

Controller model

 

Receiver firmware

 

tSurvey version

 

RTK correction method

 

Pole height

 

Tilt angle

 

Vertical measurement

 

Tilted measurements

 

Easting, northing and elevation differences

 

IMU-status screenshots

 

RTK-status screenshots

 

Site photographs

 

Description of nearby structures

 

Whether the issue occurs in open sky

 

Whether the problem changes with direction

 

A comparison table is more useful than reporting only that the tilt is “not accurate.”

 

IMU Field Test Record

 

TestPole PositionEastingNorthingElevationRTK StatusRemarks1Vertical2Small tilt3Tilt north4Tilt east5Tilt south6Tilt west

 

Record the observations before changing settings or updating firmware.

 

IMU Tilt Quality-Control Checklist

 

Before measurement:

 

Confirm Fixed status

 

Check correction age

 

Enter the correct pole height

 

Inspect the pole

 

Tighten the receiver

 

Initialize the IMU

 

Confirm the IMU-ready indication

 

Check a known point

 

During measurement:

 

Keep the pole tip fixed

 

Use the smallest practical tilt

 

Avoid excessive movement

 

Monitor RTK status

 

Repeat important points

 

Compare different directions where necessary

 

After measurement:

 

Recheck vertically

 

Review coordinate differences

 

Back up the field project

 

Record any questionable locations

 

Preserve screenshots and test results

 

TOKNAV IMU Tilt RTK Support in Malaysia

 

Contact MTM Precision for the TOKNAV T50, T10 Pro, TBase, PCR100T and tSurvey software, including IMU tilt setup, field testing, troubleshooting, demonstration and technical discussion in Malaysia.

 

MTM Precision Sdn. Bhd. (744811-A)

 

Telephone: +603-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my

Website: www.mtmpre.com.my

 

Showroom & Service Centre:

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.


 

18 Sep 2026