The Qiwei PHS-25 is an economical benchtop pH meter designed for routine laboratory testing, education, agriculture, aquaculture and general water-quality applications.

 

Compared with a pocket pH tester, its tabletop design, separate electrode holder and replaceable E201 combination electrode provide a more organised testing setup. It is suitable for customers who want an affordable laboratory-style pH meter without requiring advanced data storage or professional research-grade functions.

 

What Does the Qiwei PHS-25 Measure?

 

The Qiwei PHS-25 provides two principal measurement modes:

 

pH measurement: Determines whether a liquid is acidic, neutral or alkaline.

 

mV measurement: Displays electrode potential for applicable electrochemical testing.

 

This makes it suitable for routine testing of water samples, prepared solutions and other compatible liquids.

 

Qiwei PHS-25 Main Specifications

 

pH measuring range: 0.00–14.00 pH

 

pH resolution: 0.01 pH

 

pH accuracy: ±0.05 pH

 

mV measuring range: 0 to ±1999 mV

 

mV resolution: 1 mV

 

mV accuracy: ±10 mV

 

Temperature compensation range: 0–60°C

 

Recommended sample temperature: 5–60°C

 

Standard buffer values: pH 4.00, pH 6.86 and pH 9.18

 

Electrode: E201 combination pH electrode

 

Power supply: AC power adaptor

 

Approximate dimensions: 220 × 200 × 85 mm

 

Approximate weight: 1 kg

 

Suitable Applications

 

The Qiwei PHS-25 can be used for routine pH measurement in:

 

Schools and teaching laboratories

 

Agricultural water and fertiliser solutions

 

Aquaculture and fish-farming water

 

Drinking-water spot checks

 

Swimming pools

 

General wastewater monitoring

 

Small factory quality-control departments

 

Food and beverage process checks

 

Research and training activities

 

Routine laboratory solution testing

 

The instrument is most appropriate for general testing and trend monitoring. Customers who require higher accuracy, automatic data recording or compliance-grade laboratory documentation should select a more advanced laboratory pH meter.

 

Why Choose a Benchtop pH Meter?

 

Pocket pH testers are convenient for quick field measurements, but a benchtop instrument offers several practical advantages in a laboratory environment.

 

The electrode can be supported by a dedicated holder, helping the operator maintain a stable measuring position. The replaceable electrode also makes long-term maintenance easier than disposable or low-cost pocket testers.

 

The Qiwei PHS-25 is therefore suitable for users who:

 

Test samples regularly at a fixed workstation

 

Prefer a larger and more stable instrument

 

Need a replaceable laboratory electrode

 

Want both pH and mV measurement

 

Do not require a portable battery-powered meter

 

pH Resolution and Accuracy Are Not the Same

 

The Qiwei PHS-25 displays results with a 0.01 pH resolution, while its stated measuring accuracy is ±0.05 pH.

 

Resolution refers to the smallest change shown on the display. Accuracy indicates how close the measurement is expected to be to the actual value under suitable operating and calibration conditions.

 

For this reason, the PHS-25 should be positioned as an economical routine benchtop pH meter, rather than a high-precision analytical instrument.

 

Calibration Before Measurement

 

A pH meter should be calibrated regularly to maintain reliable results. The supplied buffer values include:

 

pH 4.00 for acidic-range calibration

 

pH 6.86 for neutral-range calibration

 

pH 9.18 for alkaline-range calibration

 

For better results, use fresh buffer solution and calibrate with buffer points that cover the expected sample range. For example, pH 4.00 and pH 6.86 are suitable when testing acidic samples.

 

Do not pour used buffer solution back into its original bottle, as contamination can change the buffer value.

 

Basic Electrode Care

 

The E201 glass electrode is the most important consumable component of the pH meter. Proper electrode care helps prevent slow response, unstable readings and calibration failure.

 

Recommended practices include:

 

Rinse the electrode with clean or distilled water between samples.

 

Blot the electrode gently instead of rubbing the glass bulb.

 

Keep the sensing bulb hydrated using the correct storage solution.

 

Do not store the electrode permanently in distilled water.

 

Remove deposits according to the sample type.

 

Replace the electrode when calibration remains unstable after cleaning.

 

Customers should consider the future availability and replacement price of the electrode when purchasing a benchtop pH meter.

 

Qiwei PHS-25 Available in Malaysia

 

The Qiwei PHS-25 benchtop pH meter is available from MTM Precision in Malaysia.

 

Customers may contact us to check current stock, package contents, electrode availability and suitability for their application. If you are uncertain whether you need a benchtop, portable or pocket pH meter, share your sample type, required accuracy and testing location with our team.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd. (744811-A)

 

Telephone: +603-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my

Website: www.mtmpre.com.my

 

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Business Hours: Monday–Friday, 9:00 AM–6:00 PM


 

19 Sep 2026