Qiwei PHS-25 pH vs EC, TDS, DO, Turbidity and Suspended Solids Malaysia
Qiwei PHS-25 pH vs EC, TDS, DO, Turbidity and Suspended Solids Malaysia
The Qiwei PHS-25 measures pH and electrode potential in mV, but pH alone cannot provide a complete assessment of water quality.
Depending on the application, customers may also need to measure conductivity, total dissolved solids, dissolved oxygen, turbidity or suspended solids.
Understanding what each parameter represents helps customers select the correct instrument instead of expecting one meter to answer every water-quality question.
Quick Water-Quality Parameter Comparison
ParameterWhat It IndicatesTypical InstrumentpHAcidity or alkalinityQiwei PHS-25ConductivityAbility of water to conduct electricityQiwei 401 conductivity meterTDSEstimated dissolved material concentrationTDS or EC/TDS meterDissolved oxygenOxygen available in waterQiwei 70A DO meterTurbidityOptical cloudiness of waterQiwei WGZ-1B turbidity meterSuspended solidsConcentration of particles suspended in waterSuspended-solids analyserORPOxidising or reducing conditionORP meter or suitable mV system
These parameters measure different properties and should not be treated as substitutes for one another.
What Does the Qiwei PHS-25 Measure?
The Qiwei PHS-25 is a benchtop instrument for:
pH measurement
mV measurement
Its principal specifications include:
pH range: 0.00–14.00 pH
pH resolution: 0.01 pH
pH accuracy: ±0.05 pH
mV range: 0 to ±1999 mV
mV resolution: 1 mV
mV accuracy: ±10 mV
Temperature-compensation range: 0–60°C
Standard electrode: E201 combination pH electrode
The PHS-25 is suitable for routine benchtop testing in schools, laboratories, aquaculture, agriculture and general factory quality control.
What Does pH Tell You?
pH indicates whether water is acidic, neutral or alkaline.
It is important because pH may affect:
Chemical reactions
Biological treatment
Corrosion
Scale formation
Fish and aquatic organisms
Ammonia toxicity
Coagulation and precipitation
Process performance
Effectiveness of water treatment
A normal pH result does not confirm that the water is clean, safe or free from dissolved and suspended contaminants.
What Does Conductivity Tell You?
Conductivity indicates how easily water carries an electrical current.
It is influenced by dissolved ions such as salts, minerals, acids and alkalis.
Conductivity testing can help operators observe:
Changes in dissolved ionic content
Process-water consistency
Rinse-water quality
Cooling-water condition
Boiler-water trends
Reverse-osmosis performance
Contamination or chemical carryover
Differences between water sources
The Qiwei 401 conductivity meter is used for conductivity measurement. It does not replace the PHS-25 because conductivity and pH describe different properties.
What Does TDS Tell You?
TDS means total dissolved solids.
Many portable TDS meters estimate TDS from the measured conductivity using a conversion factor. This means that two instruments using different factors may display different TDS values for the same sample.
TDS can be useful for:
Drinking-water screening
Aquaculture
Hydroponics
Reverse-osmosis systems
Cooling water
General process-water comparison
TDS does not identify the individual dissolved substances present. Laboratory chemical analysis may be required when the actual composition must be known.
What Does Dissolved Oxygen Tell You?
Dissolved oxygen indicates the amount of oxygen available in water.
It is especially important in:
Aquaculture
Fish ponds
Wastewater biological treatment
Rivers and environmental monitoring
Aeration systems
Water-treatment processes
Laboratory studies
The Qiwei 70A dissolved oxygen meter is used for DO measurement.
A pond may have an acceptable pH but insufficient dissolved oxygen. Similarly, a wastewater treatment system may show normal pH while its biological process is affected by low DO.
For this reason, aquaculture and biological treatment operators often need both pH and dissolved-oxygen measurements.
What Does Turbidity Tell You?
Turbidity represents the optical cloudiness of water caused by particles that scatter light.
Possible sources include:
Clay and silt
Algae
Organic matter
Fine suspended particles
Treatment-process carryover
Microbial material
The Qiwei WGZ-1B turbidity meter is intended for turbidity measurement.
Turbidity is an optical result. It does not directly state the weight of suspended solids in the sample.
What Do Suspended Solids Tell You?
Suspended-solids measurement estimates or determines the concentration of particles suspended in water.
It is commonly relevant to:
Wastewater treatment
Industrial discharge
Settling performance
Sludge monitoring
Process-water control
Environmental sampling
Suspended solids and turbidity may show a general relationship in a particular process, but they are not interchangeable.
Two samples can produce similar turbidity readings while containing different particle sizes, colours or solid concentrations.
A dedicated suspended-solids analyser or appropriate laboratory method should be used when suspended-solids concentration is required.
Turbidity vs Suspended Solids
QuestionTurbiditySuspended SolidsWhat is measured?Optical cloudinessConcentration of particlesTypical resultNTU or equivalent turbidity unitmg/L or instrument-specific resultAffected by particle colour?YesLess directlyAffected by particle size?YesMeasurement method dependentCan one replace the other?NoNoMain applicationWater clarity and process trendSolids loading and treatment performance
Customers should select the parameter stated in their process requirement or test method.
Does the PHS-25 Measure ORP?
The PHS-25 displays mV, but customers should not assume that it automatically functions as a complete ORP testing package.
ORP measurement normally requires:
A compatible ORP electrode
Correct connection
Suitable verification solution
Appropriate operating procedure
Confirmation of instrument compatibility
The supplied E201 electrode is a pH electrode. Customers requiring ORP should confirm the necessary electrode and system configuration before purchasing.
Which Instruments Are Needed for Aquaculture?
A basic aquaculture setup may include:
pH meter: Acidity and alkalinity
Dissolved-oxygen meter: Oxygen available to fish or shrimp
Temperature meter: Water temperature
Conductivity or salinity meter: Dissolved ionic content
Turbidity meter: Water cloudiness
The required parameters depend on the species, freshwater or saltwater operation and farm-management system.
For fixed indoor testing, the PHS-25 can be used at a central testing station. A portable meter may be more convenient for direct pond-side measurements.
Which Instruments Are Needed for Wastewater?
A routine wastewater laboratory may monitor:
pH
Conductivity
Dissolved oxygen
Turbidity
Suspended solids
Chemical oxygen demand
Ammonia nitrogen
Total phosphorus
Total nitrogen
Residual chlorine
ORP
The correct instrument combination depends on the treatment process and reporting requirement.
The PHS-25 can support internal pH monitoring, but formal regulatory testing may require specified methods, traceable calibration and documented laboratory procedures.
Which Instruments Are Needed for Drinking Water?
Depending on the testing objective, drinking-water screening may include:
pH
Conductivity
TDS
Turbidity
Residual chlorine
Temperature
A normal result from these field or laboratory instruments does not prove that water is microbiologically safe or free from specific chemical contaminants.
Additional laboratory analysis may be required.
How to Choose the Correct Combination
Before purchasing, identify:
What type of water is being tested?
What problem must be detected?
Which parameters are required?
Is testing performed in a laboratory or at the site?
How many samples are tested daily?
Is the result for internal checking or formal reporting?
What accuracy and measuring range are required?
Are consumables and replacement sensors available?
This information prevents the customer from buying an instrument that measures the wrong parameter.
Qiwei Water-Quality Instruments Available in Malaysia
MTM Precision carries selected Qiwei water-quality instruments in Malaysia, including models for:
pH measurement
Conductivity measurement
Dissolved-oxygen measurement
Turbidity measurement
Suspended-solids measurement
Selected models include:
Qiwei PHS-25 benchtop pH meter
Qiwei 401 conductivity meter
Qiwei 70A dissolved-oxygen meter
Qiwei WGZ-1B turbidity meter
Please contact us to confirm current stock, package contents, measuring range and suitability for your application.
Contact MTM Precision
MTM Precision Sdn. Bhd. (744811-A)
Telephone: +603-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my
Website: www.mtmpre.com.my
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Business Hours: Monday–Friday, 9:00 AM–6:00 PM
19 Sep 2026