Qiwei PHS-25 pH vs EC, TDS, DO, Turbidity and Suspended Solids Malaysia

Qiwei PHS-25 pH vs EC, TDS, DO, Turbidity and Suspended Solids Malaysia

 

The Qiwei PHS-25 measures pH and electrode potential in mV, but pH alone cannot provide a complete assessment of water quality.

 

Depending on the application, customers may also need to measure conductivity, total dissolved solids, dissolved oxygen, turbidity or suspended solids.

 

Understanding what each parameter represents helps customers select the correct instrument instead of expecting one meter to answer every water-quality question.

 

Quick Water-Quality Parameter Comparison

 

ParameterWhat It IndicatesTypical InstrumentpHAcidity or alkalinityQiwei PHS-25ConductivityAbility of water to conduct electricityQiwei 401 conductivity meterTDSEstimated dissolved material concentrationTDS or EC/TDS meterDissolved oxygenOxygen available in waterQiwei 70A DO meterTurbidityOptical cloudiness of waterQiwei WGZ-1B turbidity meterSuspended solidsConcentration of particles suspended in waterSuspended-solids analyserORPOxidising or reducing conditionORP meter or suitable mV system

 

These parameters measure different properties and should not be treated as substitutes for one another.

 

What Does the Qiwei PHS-25 Measure?

 

The Qiwei PHS-25 is a benchtop instrument for:

 

pH measurement

 

mV measurement

 

Its principal specifications include:

 

pH range: 0.00–14.00 pH

 

pH resolution: 0.01 pH

 

pH accuracy: ±0.05 pH

 

mV range: 0 to ±1999 mV

 

mV resolution: 1 mV

 

mV accuracy: ±10 mV

 

Temperature-compensation range: 0–60°C

 

Standard electrode: E201 combination pH electrode

 

The PHS-25 is suitable for routine benchtop testing in schools, laboratories, aquaculture, agriculture and general factory quality control.

 

What Does pH Tell You?

 

pH indicates whether water is acidic, neutral or alkaline.

 

It is important because pH may affect:

 

Chemical reactions

 

Biological treatment

 

Corrosion

 

Scale formation

 

Fish and aquatic organisms

 

Ammonia toxicity

 

Coagulation and precipitation

 

Process performance

 

Effectiveness of water treatment

 

A normal pH result does not confirm that the water is clean, safe or free from dissolved and suspended contaminants.

 

What Does Conductivity Tell You?

 

Conductivity indicates how easily water carries an electrical current.

 

It is influenced by dissolved ions such as salts, minerals, acids and alkalis.

 

Conductivity testing can help operators observe:

 

Changes in dissolved ionic content

 

Process-water consistency

 

Rinse-water quality

 

Cooling-water condition

 

Boiler-water trends

 

Reverse-osmosis performance

 

Contamination or chemical carryover

 

Differences between water sources

 

The Qiwei 401 conductivity meter is used for conductivity measurement. It does not replace the PHS-25 because conductivity and pH describe different properties.

 

What Does TDS Tell You?

 

TDS means total dissolved solids.

 

Many portable TDS meters estimate TDS from the measured conductivity using a conversion factor. This means that two instruments using different factors may display different TDS values for the same sample.

 

TDS can be useful for:

 

Drinking-water screening

 

Aquaculture

 

Hydroponics

 

Reverse-osmosis systems

 

Cooling water

 

General process-water comparison

 

TDS does not identify the individual dissolved substances present. Laboratory chemical analysis may be required when the actual composition must be known.

 

What Does Dissolved Oxygen Tell You?

 

Dissolved oxygen indicates the amount of oxygen available in water.

 

It is especially important in:

 

Aquaculture

 

Fish ponds

 

Wastewater biological treatment

 

Rivers and environmental monitoring

 

Aeration systems

 

Water-treatment processes

 

Laboratory studies

 

The Qiwei 70A dissolved oxygen meter is used for DO measurement.

 

A pond may have an acceptable pH but insufficient dissolved oxygen. Similarly, a wastewater treatment system may show normal pH while its biological process is affected by low DO.

 

For this reason, aquaculture and biological treatment operators often need both pH and dissolved-oxygen measurements.

 

What Does Turbidity Tell You?

 

Turbidity represents the optical cloudiness of water caused by particles that scatter light.

 

Possible sources include:

 

Clay and silt

 

Algae

 

Organic matter

 

Fine suspended particles

 

Treatment-process carryover

 

Microbial material

 

The Qiwei WGZ-1B turbidity meter is intended for turbidity measurement.

 

Turbidity is an optical result. It does not directly state the weight of suspended solids in the sample.

 

What Do Suspended Solids Tell You?

 

Suspended-solids measurement estimates or determines the concentration of particles suspended in water.

 

It is commonly relevant to:

 

Wastewater treatment

 

Industrial discharge

 

Settling performance

 

Sludge monitoring

 

Process-water control

 

Environmental sampling

 

Suspended solids and turbidity may show a general relationship in a particular process, but they are not interchangeable.

 

Two samples can produce similar turbidity readings while containing different particle sizes, colours or solid concentrations.

 

A dedicated suspended-solids analyser or appropriate laboratory method should be used when suspended-solids concentration is required.

 

Turbidity vs Suspended Solids

 

QuestionTurbiditySuspended SolidsWhat is measured?Optical cloudinessConcentration of particlesTypical resultNTU or equivalent turbidity unitmg/L or instrument-specific resultAffected by particle colour?YesLess directlyAffected by particle size?YesMeasurement method dependentCan one replace the other?NoNoMain applicationWater clarity and process trendSolids loading and treatment performance

 

Customers should select the parameter stated in their process requirement or test method.

 

Does the PHS-25 Measure ORP?

 

The PHS-25 displays mV, but customers should not assume that it automatically functions as a complete ORP testing package.

 

ORP measurement normally requires:

 

A compatible ORP electrode

 

Correct connection

 

Suitable verification solution

 

Appropriate operating procedure

 

Confirmation of instrument compatibility

 

The supplied E201 electrode is a pH electrode. Customers requiring ORP should confirm the necessary electrode and system configuration before purchasing.

 

Which Instruments Are Needed for Aquaculture?

 

A basic aquaculture setup may include:

 

pH meter: Acidity and alkalinity

 

Dissolved-oxygen meter: Oxygen available to fish or shrimp

 

Temperature meter: Water temperature

 

Conductivity or salinity meter: Dissolved ionic content

 

Turbidity meter: Water cloudiness

 

The required parameters depend on the species, freshwater or saltwater operation and farm-management system.

 

For fixed indoor testing, the PHS-25 can be used at a central testing station. A portable meter may be more convenient for direct pond-side measurements.

 

Which Instruments Are Needed for Wastewater?

 

A routine wastewater laboratory may monitor:

 

pH

 

Conductivity

 

Dissolved oxygen

 

Turbidity

 

Suspended solids

 

Chemical oxygen demand

 

Ammonia nitrogen

 

Total phosphorus

 

Total nitrogen

 

Residual chlorine

 

ORP

 

The correct instrument combination depends on the treatment process and reporting requirement.

 

The PHS-25 can support internal pH monitoring, but formal regulatory testing may require specified methods, traceable calibration and documented laboratory procedures.

 

Which Instruments Are Needed for Drinking Water?

 

Depending on the testing objective, drinking-water screening may include:

 

pH

 

Conductivity

 

TDS

 

Turbidity

 

Residual chlorine

 

Temperature

 

A normal result from these field or laboratory instruments does not prove that water is microbiologically safe or free from specific chemical contaminants.

 

Additional laboratory analysis may be required.

 

How to Choose the Correct Combination

 

Before purchasing, identify:

 

What type of water is being tested?

 

What problem must be detected?

 

Which parameters are required?

 

Is testing performed in a laboratory or at the site?

 

How many samples are tested daily?

 

Is the result for internal checking or formal reporting?

 

What accuracy and measuring range are required?

 

Are consumables and replacement sensors available?

 

This information prevents the customer from buying an instrument that measures the wrong parameter.

 

Qiwei Water-Quality Instruments Available in Malaysia

 

MTM Precision carries selected Qiwei water-quality instruments in Malaysia, including models for:

 

pH measurement

 

Conductivity measurement

 

Dissolved-oxygen measurement

 

Turbidity measurement

 

Suspended-solids measurement

 

Selected models include:

 

Qiwei PHS-25 benchtop pH meter

 

Qiwei 401 conductivity meter

 

Qiwei 70A dissolved-oxygen meter

 

Qiwei WGZ-1B turbidity meter

 

Please contact us to confirm current stock, package contents, measuring range and suitability for your application.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd. (744811-A)

 

Telephone: +603-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my

Website: www.mtmpre.com.my

 

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Business Hours: Monday–Friday, 9:00 AM–6:00 PM


 

19 Sep 2026