Qiwei PHS-25 for Wastewater pH Testing in Factory Laboratories Malaysia
Qiwei PHS-25 for Wastewater pH Testing in Factory Laboratories Malaysia
The Qiwei PHS-25 benchtop pH meter can be used for routine wastewater pH checks in factory laboratories, treatment facilities and internal quality-control stations.
It is an economical laboratory-style instrument with pH and mV functions, a separate E201 combination electrode and an electrode holder.
The PHS-25 is best suited for internal monitoring and trend checking at a fixed testing station. Customers requiring results for regulatory submission or accredited reporting must first confirm the applicable test method, accuracy and calibration-traceability requirements.
Why Monitor Wastewater pH?
pH is one of the basic parameters used to observe wastewater conditions and treatment performance.
Abnormal pH may:
Affect biological treatment processes
Reduce treatment efficiency
Indicate a chemical-dosing problem
Damage pumps, pipes or treatment equipment
Affect coagulation and precipitation
Change the behaviour of dissolved contaminants
Affect the toxicity of certain substances
Indicate an unexpected process discharge
Monitoring pH at several treatment stages helps operators identify changes before the final discharge point.
Qiwei PHS-25 Main Specifications
pH measuring range: 0.00–14.00 pH
pH resolution: 0.01 pH
pH accuracy: ±0.05 pH
mV measuring range: 0 to ±1999 mV
mV resolution: 1 mV
mV accuracy: ±10 mV
Temperature-compensation range: 0–60°C
Standard buffer values: pH 4.00, pH 6.86 and pH 9.18
Standard electrode: E201 combination pH electrode
Power supply: AC power adaptor
Approximate dimensions: 220 × 200 × 85 mm
Approximate weight: 1 kg
Suitable Wastewater Applications
The Qiwei PHS-25 may be considered for routine samples collected from:
Equalisation tanks
Neutralisation tanks
Biological treatment systems
Chemical-treatment processes
Settling tanks
Process-water drains
Final treated water
Internal wastewater laboratories
Incoming and outgoing treatment stages
General factory water systems
The instrument should be installed in a clean, dry testing area rather than beside an exposed treatment tank.
Why Use a Benchtop Meter?
A benchtop pH meter is useful when samples from different treatment points are brought to a central laboratory.
Advantages include:
Stable testing position
Separate and replaceable electrode
Dedicated electrode holder
AC-powered operation
Convenient testing of multiple samples
pH and mV measurement
Easier implementation of a standard laboratory procedure
For direct measurement at tanks, drains or outdoor treatment areas, a waterproof portable pH meter may be more suitable.
Suggested Wastewater Sampling Points
A factory may monitor pH at several locations, depending on its treatment design.
Possible sampling points include:
Raw wastewater inlet
Equalisation tank
After acid or alkali dosing
Biological treatment stage
Clarification or settling stage
Final treatment stage
Discharge point
Using consistent sampling locations allows the operator to compare results and identify where a pH change occurs.
Basic Testing Procedure
Collect the sample using a clean, suitable container.
Label the sampling location, date and time.
Test the sample as soon as practical.
Calibrate the PHS-25 with fresh buffer solution.
Rinse the E201 electrode with distilled or deionised water.
Gently blot away excess rinse water.
Immerse the electrode bulb and reference junction in the sample.
Move the electrode gently to release trapped air.
Allow the reading to stabilise.
Record the pH value and sample temperature.
Rinse the electrode before testing the next sample.
Clean and store the electrode correctly after use.
Follow the facility’s safety and sampling procedures when handling unknown or hazardous wastewater.
Selecting the Correct Calibration Buffers
The calibration buffers should cover the expected sample range.
For Acidic Wastewater
Use:
pH 6.86
pH 4.00
For Alkaline Wastewater
Use:
pH 6.86
pH 9.18
For Samples Near Neutral
Start with the pH 6.86 buffer and use an appropriate second point when better confidence across the operating range is required.
Always use fresh, uncontaminated buffer solution.
Challenges When Measuring Wastewater
Wastewater is often more difficult to measure than clean water because it may contain suspended solids, oil, chemicals and biological material.
Suspended Solids
Particles can collect around the electrode bulb or reference junction and produce a slow response.
Oil and Grease
Oil may coat the glass surface and prevent proper contact with the sample.
High or Low Temperature
A sample that is much hotter or colder than the calibration buffer may take longer to stabilise.
Chemical Residue
Strong chemicals may affect electrode performance or shorten its service life.
Electrical Interference
Motors, pumps and treatment equipment may introduce interference if the meter is installed too close to industrial machinery.
Changing Samples
Some wastewater continues reacting after collection. Delayed testing may produce a result that does not represent conditions at the sampling point.
Cleaning the Electrode
After testing wastewater:
Rinse the electrode thoroughly.
Inspect the glass bulb and junction.
Remove visible contamination using a suitable cleaning method.
Recondition the electrode when necessary.
Recalibrate before the next important measurement.
Store it in the correct electrode storage solution.
Do not use abrasive materials on the glass bulb.
Different contaminants may require different cleaning solutions. The operator should follow the electrode manufacturer’s recommendations and the facility’s chemical-safety procedure.
When Should the Electrode Be Replaced?
Consider electrode replacement when:
Calibration repeatedly fails.
Readings remain unstable in fresh buffer.
Response is extremely slow.
Results cannot be repeated.
The glass bulb is cracked.
The cable or connector is damaged.
Cleaning and rehydration do not restore performance.
Testing the PHS-25 with a known working electrode can help determine whether the fault comes from the electrode or the main instrument.
PHS-25 vs Online pH Controller
The Qiwei PHS-25 is a laboratory instrument. It is not an online pH controller.
FunctionQiwei PHS-25Online pH ControllerMeasurement methodCollected sampleContinuous process measurementInstallationLaboratory benchTank, pipe or process linePowerAC adaptorFixed electrical installationContinuous outputNoModel dependentDosing controlNoAvailable on selected systemsBest useRoutine sample testingContinuous monitoring and process control
Factories needing continuous pH monitoring, alarms or chemical-dosing control should consider an industrial online pH system.
Is the PHS-25 Suitable for Regulatory Reporting?
The PHS-25 has a stated accuracy of ±0.05 pH.
It can be useful for internal checks and observing treatment trends, but regulatory or accredited testing may require:
A specified test method
Suitable instrument accuracy
Traceable calibration
Certified buffer solutions
Documented quality-control procedures
Maintenance and calibration records
Laboratory accreditation
Customers should verify these requirements before using any instrument for formal compliance reporting.
Other Wastewater Parameters to Consider
pH alone does not provide a complete picture of treatment performance.
Depending on the application, additional parameters may include:
Chemical oxygen demand
Dissolved oxygen
Ammonia nitrogen
Total phosphorus
Total nitrogen
Turbidity
Suspended solids
Conductivity
Oxidation-reduction potential
Residual chlorine
Temperature
MTM Precision can assist customers in identifying instruments for a broader routine water-quality testing setup.
Qiwei PHS-25 Available in Malaysia
The Qiwei PHS-25 benchtop pH meter is available from MTM Precision in Malaysia.
Factories and wastewater operators may contact us for stock confirmation, package details, replacement-electrode availability and assistance choosing between benchtop, portable and online pH instruments.
For a suitable recommendation, please provide:
Type of wastewater
Expected pH range
Sample temperature
Testing location
Testing frequency
Required reporting standard
Whether continuous monitoring is needed
Contact MTM Precision
MTM Precision Sdn. Bhd. (744811-A)
Telephone: +603-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my
Website: www.mtmpre.com.my
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Business Hours: Monday–Friday, 9:00 AM–6:00 PM
19 Sep 2026