Qiwei PHS-25 pH Meter for Schools and Teaching Laboratories Malaysia
Qiwei PHS-25 pH Meter for Schools and Teaching Laboratories Malaysia
The Qiwei PHS-25 benchtop pH meter is an economical option for schools, colleges, universities, training centres and basic teaching laboratories that require a dedicated instrument for demonstrating pH measurement.
Its tabletop design, separate E201 combination electrode and electrode holder provide students with a more complete laboratory experience than a basic pocket pH tester.
The instrument measures both pH and mV, making it suitable for introductory lessons involving acidity, alkalinity and electrode potential.
Why Use a Benchtop pH Meter for Teaching?
Pocket testers are convenient, but a benchtop instrument allows students to observe the complete measurement process.
Students can learn how to:
Inspect and connect a pH electrode
Prepare buffer solutions
Perform pH calibration
Rinse the electrode correctly
Avoid cross-contamination
Wait for the reading to stabilise
Record pH and sample temperature
Clean and store the electrode after use
Identify common measurement errors
These skills are useful for students studying chemistry, biology, environmental science, agriculture, food technology and water-quality testing.
Qiwei PHS-25 Main Specifications
pH measuring range: 0.00–14.00 pH
pH resolution: 0.01 pH
pH accuracy: ±0.05 pH
mV measuring range: 0 to ±1999 mV
mV resolution: 1 mV
mV accuracy: ±10 mV
Temperature-compensation range: 0–60°C
Standard buffer values: pH 4.00, pH 6.86 and pH 9.18
Electrode: E201 combination pH electrode
Power supply: AC power adaptor
Approximate dimensions: 220 × 200 × 85 mm
Approximate weight: 1 kg
Suitable Educational Experiments
The Qiwei PHS-25 can support a variety of basic laboratory activities.
Comparing Acidic and Alkaline Solutions
Students can measure and compare the pH of different compatible liquids to understand the pH scale.
Water-Quality Experiments
The meter can be used to compare tap water, rainwater, pond water, aquarium water and other prepared water samples.
Soil and Agricultural Studies
Students can prepare a soil-water extract and study how different soil samples vary in pH.
A suitable and consistent sample-preparation method should be followed so that results can be compared meaningfully.
Acid–Base Titration Demonstration
The mV and pH response can help students observe how a solution changes as acid or alkali is added.
Buffer-Solution Demonstration
Students can learn why buffer solutions resist rapid pH changes and why certified buffers are used for instrument calibration.
Temperature and pH Observation
The class can observe how electrode response and the actual behaviour of a solution may change with temperature.
Is the PHS-25 Accurate Enough for School Use?
The Qiwei PHS-25 has a stated pH accuracy of ±0.05 pH and a display resolution of 0.01 pH.
This is generally appropriate for:
Classroom demonstrations
Student laboratory exercises
General comparison between samples
Introductory water-quality studies
Basic agricultural testing
Routine training activities
However, it may not be suitable for advanced analytical research, regulated testing or experiments that require an accuracy of ±0.01 pH.
The display showing two decimal places should not be interpreted as analytical accuracy to two decimal places.
PHS-25 vs Pocket pH Tester for Students
ConsiderationQiwei PHS-25Pocket pH TesterInstrument typeBenchtopHandheld or pen typeTeaching visibilityBetter for group demonstrationBetter for individual fieldworkElectrodeSeparate and replaceableUsually integratedElectrode holderIncludedNot requiredpH and mV functionsAvailablemV usually unavailablePower sourceAC adaptorBatteryPortabilityLimitedHighBest applicationLaboratory lessonsOutdoor and quick checks
For a fixed science laboratory, the PHS-25 provides a more structured testing setup. For outdoor sampling trips, a portable or pocket meter may be more convenient.
Recommended Laboratory Setup
A complete teaching station should include:
Qiwei PHS-25 main unit
E201 combination electrode
Electrode holder and clamp
Fresh calibration buffers
Electrode storage solution
Distilled or deionised rinse water
Clean sample beakers
Wash bottle
Laboratory tissue
Thermometer
Student measurement log
Schools purchasing multiple units should also consider keeping at least one replacement electrode available.
Basic Student Operating Procedure
A simple teaching procedure can include the following steps:
Inspect the electrode for damage.
Prepare fresh calibration buffer in a clean beaker.
Rinse the electrode with distilled water.
Gently blot away excess water.
Calibrate the meter according to the operating instructions.
Rinse the electrode again.
Place it into the sample.
Ensure the glass bulb and junction are immersed.
Wait for the reading to stabilise.
Record the pH value and sample temperature.
Rinse the electrode between samples.
Store the electrode correctly after the lesson.
The instructor should supervise the handling of acidic, alkaline or chemically hazardous samples.
Preventing Damage in a Shared Laboratory
School instruments are often used by many students, so clear handling rules are important.
Do Not Hit the Glass Bulb
The sensing bulb is fragile. The electrode should not be dropped or allowed to strike the beaker.
Do Not Pull the Electrode Cable
Disconnect the electrode using its connector rather than pulling on the cable.
Do Not Mix Calibration Buffers
Always rinse the electrode before moving it from one buffer to another.
Do Not Store the Electrode Dry
The electrode should be kept hydrated using the correct storage solution.
Do Not Store It Permanently in Distilled Water
Distilled water is suitable for rinsing but generally unsuitable for long-term electrode storage.
Label Each Instrument
When several units are used, label the main unit, electrode and adaptor so that each set can be kept together.
Consumables and Maintenance
The E201 pH electrode is a consumable item. Its service life depends on:
Frequency of use
Sample type
Cleaning procedure
Storage condition
Student handling
Exposure to strong chemicals
Physical damage
A slow or unstable reading is often caused by electrode condition rather than a defective main instrument.
Schools should budget for buffer solution, storage solution and future electrode replacement.
Who Should Consider the Qiwei PHS-25?
The model is suitable for:
Secondary-school science laboratories
Colleges and universities
Technical and vocational institutes
Agricultural training centres
Environmental-science programmes
Food-technology classes
Water-treatment training
Internal company training laboratories
It is particularly suitable when the priority is an affordable, easy-to-understand benchtop pH system for routine education and demonstration.
Qiwei PHS-25 Available in Malaysia
The Qiwei PHS-25 benchtop pH meter is available from MTM Precision in Malaysia.
Schools, laboratories and training centres may contact us for stock confirmation, package details and assistance planning the required quantity, buffer solutions and replacement electrodes.
For a suitable recommendation, please provide:
Number of student groups
Expected number of instruments
Type of experiments
Required pH accuracy
Samples being tested
Whether field measurement is also required
Contact MTM Precision
MTM Precision Sdn. Bhd. (744811-A)
Telephone: +603-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my
Website: www.mtmpre.com.my
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Business Hours: Monday–Friday, 9:00 AM–6:00 PM
19 Sep 2026