Qiwei PHS-25 pH Meter for Schools and Teaching Laboratories Malaysia

Qiwei PHS-25 pH Meter for Schools and Teaching Laboratories Malaysia

 

The Qiwei PHS-25 benchtop pH meter is an economical option for schools, colleges, universities, training centres and basic teaching laboratories that require a dedicated instrument for demonstrating pH measurement.

 

Its tabletop design, separate E201 combination electrode and electrode holder provide students with a more complete laboratory experience than a basic pocket pH tester.

 

The instrument measures both pH and mV, making it suitable for introductory lessons involving acidity, alkalinity and electrode potential.

 

Why Use a Benchtop pH Meter for Teaching?

 

Pocket testers are convenient, but a benchtop instrument allows students to observe the complete measurement process.

 

Students can learn how to:

 

Inspect and connect a pH electrode

 

Prepare buffer solutions

 

Perform pH calibration

 

Rinse the electrode correctly

 

Avoid cross-contamination

 

Wait for the reading to stabilise

 

Record pH and sample temperature

 

Clean and store the electrode after use

 

Identify common measurement errors

 

These skills are useful for students studying chemistry, biology, environmental science, agriculture, food technology and water-quality testing.

 

Qiwei PHS-25 Main Specifications

 

pH measuring range: 0.00–14.00 pH

 

pH resolution: 0.01 pH

 

pH accuracy: ±0.05 pH

 

mV measuring range: 0 to ±1999 mV

 

mV resolution: 1 mV

 

mV accuracy: ±10 mV

 

Temperature-compensation range: 0–60°C

 

Standard buffer values: pH 4.00, pH 6.86 and pH 9.18

 

Electrode: E201 combination pH electrode

 

Power supply: AC power adaptor

 

Approximate dimensions: 220 × 200 × 85 mm

 

Approximate weight: 1 kg

 

Suitable Educational Experiments

 

The Qiwei PHS-25 can support a variety of basic laboratory activities.

 

Comparing Acidic and Alkaline Solutions

 

Students can measure and compare the pH of different compatible liquids to understand the pH scale.

 

Water-Quality Experiments

 

The meter can be used to compare tap water, rainwater, pond water, aquarium water and other prepared water samples.

 

Soil and Agricultural Studies

 

Students can prepare a soil-water extract and study how different soil samples vary in pH.

 

A suitable and consistent sample-preparation method should be followed so that results can be compared meaningfully.

 

Acid–Base Titration Demonstration

 

The mV and pH response can help students observe how a solution changes as acid or alkali is added.

 

Buffer-Solution Demonstration

 

Students can learn why buffer solutions resist rapid pH changes and why certified buffers are used for instrument calibration.

 

Temperature and pH Observation

 

The class can observe how electrode response and the actual behaviour of a solution may change with temperature.

 

Is the PHS-25 Accurate Enough for School Use?

 

The Qiwei PHS-25 has a stated pH accuracy of ±0.05 pH and a display resolution of 0.01 pH.

 

This is generally appropriate for:

 

Classroom demonstrations

 

Student laboratory exercises

 

General comparison between samples

 

Introductory water-quality studies

 

Basic agricultural testing

 

Routine training activities

 

However, it may not be suitable for advanced analytical research, regulated testing or experiments that require an accuracy of ±0.01 pH.

 

The display showing two decimal places should not be interpreted as analytical accuracy to two decimal places.

 

PHS-25 vs Pocket pH Tester for Students

 

ConsiderationQiwei PHS-25Pocket pH TesterInstrument typeBenchtopHandheld or pen typeTeaching visibilityBetter for group demonstrationBetter for individual fieldworkElectrodeSeparate and replaceableUsually integratedElectrode holderIncludedNot requiredpH and mV functionsAvailablemV usually unavailablePower sourceAC adaptorBatteryPortabilityLimitedHighBest applicationLaboratory lessonsOutdoor and quick checks

 

For a fixed science laboratory, the PHS-25 provides a more structured testing setup. For outdoor sampling trips, a portable or pocket meter may be more convenient.

 

Recommended Laboratory Setup

 

A complete teaching station should include:

 

Qiwei PHS-25 main unit

 

E201 combination electrode

 

Electrode holder and clamp

 

Fresh calibration buffers

 

Electrode storage solution

 

Distilled or deionised rinse water

 

Clean sample beakers

 

Wash bottle

 

Laboratory tissue

 

Thermometer

 

Student measurement log

 

Schools purchasing multiple units should also consider keeping at least one replacement electrode available.

 

Basic Student Operating Procedure

 

A simple teaching procedure can include the following steps:

 

Inspect the electrode for damage.

 

Prepare fresh calibration buffer in a clean beaker.

 

Rinse the electrode with distilled water.

 

Gently blot away excess water.

 

Calibrate the meter according to the operating instructions.

 

Rinse the electrode again.

 

Place it into the sample.

 

Ensure the glass bulb and junction are immersed.

 

Wait for the reading to stabilise.

 

Record the pH value and sample temperature.

 

Rinse the electrode between samples.

 

Store the electrode correctly after the lesson.

 

The instructor should supervise the handling of acidic, alkaline or chemically hazardous samples.

 

Preventing Damage in a Shared Laboratory

 

School instruments are often used by many students, so clear handling rules are important.

 

Do Not Hit the Glass Bulb

 

The sensing bulb is fragile. The electrode should not be dropped or allowed to strike the beaker.

 

Do Not Pull the Electrode Cable

 

Disconnect the electrode using its connector rather than pulling on the cable.

 

Do Not Mix Calibration Buffers

 

Always rinse the electrode before moving it from one buffer to another.

 

Do Not Store the Electrode Dry

 

The electrode should be kept hydrated using the correct storage solution.

 

Do Not Store It Permanently in Distilled Water

 

Distilled water is suitable for rinsing but generally unsuitable for long-term electrode storage.

 

Label Each Instrument

 

When several units are used, label the main unit, electrode and adaptor so that each set can be kept together.

 

Consumables and Maintenance

 

The E201 pH electrode is a consumable item. Its service life depends on:

 

Frequency of use

 

Sample type

 

Cleaning procedure

 

Storage condition

 

Student handling

 

Exposure to strong chemicals

 

Physical damage

 

A slow or unstable reading is often caused by electrode condition rather than a defective main instrument.

 

Schools should budget for buffer solution, storage solution and future electrode replacement.

 

Who Should Consider the Qiwei PHS-25?

 

The model is suitable for:

 

Secondary-school science laboratories

 

Colleges and universities

 

Technical and vocational institutes

 

Agricultural training centres

 

Environmental-science programmes

 

Food-technology classes

 

Water-treatment training

 

Internal company training laboratories

 

It is particularly suitable when the priority is an affordable, easy-to-understand benchtop pH system for routine education and demonstration.

 

Qiwei PHS-25 Available in Malaysia

 

The Qiwei PHS-25 benchtop pH meter is available from MTM Precision in Malaysia.

 

Schools, laboratories and training centres may contact us for stock confirmation, package details and assistance planning the required quantity, buffer solutions and replacement electrodes.

 

For a suitable recommendation, please provide:

 

Number of student groups

 

Expected number of instruments

 

Type of experiments

 

Required pH accuracy

 

Samples being tested

 

Whether field measurement is also required

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd. (744811-A)

 

Telephone: +603-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my

Website: www.mtmpre.com.my

 

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Business Hours: Monday–Friday, 9:00 AM–6:00 PM


 

19 Sep 2026