Qiwei PHS-25 for Aquaculture Water pH Testing Malaysia

Qiwei PHS-25 for Aquaculture Water pH Testing Malaysia

 

Maintaining a suitable pH level is an important part of aquaculture water management.

 

The Qiwei PHS-25 benchtop pH meter provides an economical solution for routine testing of water samples collected from fish ponds, shrimp farms, hatcheries and aquaculture tanks.

 

It is designed for use at a fixed testing station. Water samples can be collected from different locations and brought to the instrument for pH measurement.

 

Why Is pH Important in Aquaculture?

 

pH indicates whether water is acidic, neutral or alkaline.

 

Significant pH changes can affect:

 

Fish and shrimp stress levels

 

Feeding behaviour

 

Biological activity

 

Ammonia toxicity

 

Microbial processes

 

Pond-treatment effectiveness

 

Water stability

 

Overall animal health

 

There is no single ideal pH value for every aquaculture operation. The appropriate range depends on the species, growth stage, water source, alkalinity, temperature and farm-management system.

 

Operators should follow the recommended limits for the species being cultivated.

 

Qiwei PHS-25 Main Specifications

 

pH measuring range: 0.00–14.00 pH

 

pH resolution: 0.01 pH

 

pH accuracy: ±0.05 pH

 

mV measuring range: 0 to ±1999 mV

 

mV resolution: 1 mV

 

mV accuracy: ±10 mV

 

Temperature-compensation range: 0–60°C

 

Standard buffer values: pH 4.00, pH 6.86 and pH 9.18

 

Standard electrode: E201 combination pH electrode

 

Power supply: AC power adaptor

 

Approximate dimensions: 220 × 200 × 85 mm

 

Approximate weight: 1 kg

 

Suitable Aquaculture Applications

 

The PHS-25 can be used for routine testing of samples from:

 

Freshwater fish ponds

 

Shrimp ponds

 

Hatcheries

 

Aquaculture tanks

 

Recirculating aquaculture systems

 

Water-storage tanks

 

Incoming water supplies

 

Discharge water

 

Biofilter systems

 

Laboratory-prepared aquaculture samples

 

Because it is an AC-powered benchtop instrument, it is most suitable for a farm office, testing room or laboratory.

 

Benchtop Meter or Portable Meter?

 

The correct choice depends on how the farm conducts its testing.

 

Choose the Qiwei PHS-25 When:

 

Water samples are brought to a central testing station.

 

Several samples are measured at the same table.

 

A separate replaceable electrode is preferred.

 

pH and mV functions are required.

 

An economical laboratory-style meter is sufficient.

 

Choose a Portable pH Meter When:

 

Measurements must be taken directly beside the pond.

 

Sampling locations are far apart.

 

AC power is unavailable.

 

The operator travels between different farms.

 

Waterproof protection is required.

 

The PHS-25 should not be positioned as a pond-side field meter unless a suitable power supply and protected testing area are available.

 

Recommended Sampling Locations

 

Testing only one location may not represent the condition of an entire pond.

 

Depending on the farm layout, operators may collect samples from:

 

Water inlet

 

Pond centre

 

Feeding area

 

Near the aerator

 

Pond outlet

 

Surface level

 

Selected deeper locations

 

Treatment or filtration area

 

The sampling method, location and depth should remain consistent when comparing results over time.

 

Test the Sample Promptly

 

Aquaculture-water pH can change after a sample is collected.

 

Carbon dioxide may enter or leave the sample, while temperature and biological activity may also change. For this reason, the water should be tested as soon as reasonably possible.

 

Avoid leaving samples:

 

In direct sunlight

 

Inside a hot vehicle

 

In an open container for a long period

 

Near chemicals or cleaning products

 

At a temperature very different from the pond

 

Record the sampling time and measurement time when results are important.

 

Suggested Measurement Procedure

 

Collect the water sample in a clean container.

 

Label the sampling location and time.

 

Calibrate the PHS-25 using fresh buffer solution.

 

Rinse the E201 electrode with distilled or deionised water.

 

Gently blot away excess water.

 

Place the electrode into the sample.

 

Ensure the glass bulb and reference junction are immersed.

 

Move the electrode gently to release trapped air.

 

Allow the reading to stabilise.

 

Record the pH value and sample temperature.

 

Rinse the electrode before testing the next sample.

 

Store the electrode correctly after testing.

 

Use a separate clean container for each location to prevent cross-contamination.

 

When Should Aquaculture Water Be Tested?

 

pH does not necessarily remain constant throughout the day.

 

Photosynthesis, respiration, carbon dioxide and biological activity may produce different readings in the morning and afternoon.

 

A monitoring programme may include testing:

 

At a consistent time each day

 

In the early morning

 

In the late afternoon

 

After heavy rain

 

After adding water

 

After pond treatment

 

When feeding activity changes

 

When fish or shrimp show unusual behaviour

 

After an aeration problem

 

During an algae bloom

 

The frequency should be based on the farm’s risk level, species and operating procedure.

 

Do Not Rely on pH Alone

 

A normal pH result does not confirm that all water conditions are acceptable.

 

Aquaculture operators may also need to monitor:

 

Dissolved oxygen

 

Water temperature

 

Ammonia

 

Nitrite

 

Salinity

 

Conductivity

 

Total dissolved solids

 

Alkalinity

 

Turbidity

 

Oxidation-reduction potential

 

The appropriate parameters depend on whether the operation involves freshwater fish, marine species, shrimp, hatcheries or recirculating systems.

 

How Rain Can Affect Pond pH

 

Heavy rain can change the chemistry of pond water through dilution, runoff and reduced alkalinity.

 

A sudden pH change after rainfall may indicate that the pond has limited buffering capacity. Operators should compare pH readings with historical records and other parameters rather than reacting to a single result without context.

 

Samples should be collected using the same method before and after the event.

 

Relationship Between pH and Ammonia

 

The toxicity of ammonia is influenced by pH and temperature.

 

As pH and temperature change, the proportion of the more toxic un-ionised ammonia may also change. Therefore, an ammonia result should be interpreted together with pH and temperature.

 

The PHS-25 measures pH, but it does not directly measure ammonia. A separate ammonia testing method is required.

 

Electrode Cleaning After Pond-Water Testing

 

Pond and aquaculture samples may contain:

 

Algae

 

Suspended solids

 

Feed particles

 

Organic matter

 

Sludge

 

Biological film

 

These materials can coat the electrode and cause slow or unstable readings.

 

After testing:

 

Rinse the electrode thoroughly.

 

Inspect the glass bulb and junction.

 

Clean it using a method suitable for the contamination.

 

Recondition it if necessary.

 

Store it in the correct electrode storage solution.

 

Do not scrub the glass bulb with abrasive material.

 

Is the PHS-25 Suitable for Compliance Testing?

 

The Qiwei PHS-25 has a stated accuracy of ±0.05 pH and is best positioned for routine monitoring, general checking and trend observation.

 

If results will be used for regulatory reporting, accredited laboratory analysis or formal certification, the customer should confirm the required instrument accuracy, calibration traceability and approved testing method before purchasing.

 

Qiwei PHS-25 Available in Malaysia

 

The Qiwei PHS-25 benchtop pH meter is available from MTM Precision in Malaysia.

 

Aquaculture operators may contact us for stock confirmation, package details, replacement-electrode availability and assistance choosing between benchtop, portable and pocket pH meters.

 

For a suitable recommendation, please provide:

 

Fish or shrimp species

 

Freshwater or saltwater application

 

Number of ponds or tanks

 

Testing location

 

Required accuracy

 

Other water parameters being monitored

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd. (744811-A)

 

Telephone: +603-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my

Website: www.mtmpre.com.my

 

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Business Hours: Monday–Friday, 9:00 AM–6:00 PM


 

19 Sep 2026