RF Radiation Measurement Near Mobile Phone Base Stations Malaysia
RF Radiation Measurement Near Mobile Phone Base Stations Malaysia
Mobile phone base stations, telecommunications antennas and other wireless transmission systems generate radio-frequency electromagnetic fields as part of normal operation.
For technicians, facility teams, safety personnel and users who need to investigate the RF environment around telecommunications equipment, a portable RF field strength meter can provide useful measurements at selected locations.
The TENMARS TM-195 3-Axis RF Field Strength Meter is designed for broadband RF electromagnetic field measurement within 50 MHz to 3.5 GHz.
It can be used for general RF field surveys around compatible telecommunications and wireless transmitting equipment in Malaysia.
Why Measure RF Fields Near Base Stations?
Seeing a telecommunications antenna does not tell you the RF field strength at a particular location.
Actual measured RF levels can vary according to factors such as:
Distance from the transmitting antenna
Antenna direction
Transmitter operating conditions
Measurement height
Buildings and other structures
Reflections
Multiple RF sources
Location of the measurement point
For this reason, actual field measurements can provide more useful information than estimating RF levels based only on visual distance from an antenna.
What Does the TENMARS TM-195 Measure?
The TENMARS TM-195 measures broadband RF electromagnetic field strength.
Its supported frequency range is:
50 MHz to 3.5 GHz
Measurement values can be displayed using units including:
V/m
A/m
mW/m²
W/m²
µW/cm²
mW/cm²
This allows users to record RF field strength or power density depending on the measurement requirement.
3-Axis RF Measurement
RF fields do not necessarily arrive at a measurement point from only one direction.
This is particularly relevant in urban environments where buildings, metal structures and multiple transmitting sources may affect RF propagation.
The TM-195 uses a 3-axis measurement system.
This allows the meter to measure multiple spatial components of the RF field without requiring the user to repeatedly rotate the instrument to find a particular orientation.
For general field surveys, this makes measurement more convenient and repeatable.
How to Measure RF Near a Mobile Base Station
A useful RF survey should involve more than taking one measurement.
Start by identifying the area to be investigated.
Then select several measurement locations.
For example:
Point A – normal occupied area
Point B – closer to the telecommunications installation
Point C – another occupied location
Point D – different floor or building position
Point E – reference location farther from the suspected source
Use the same measurement unit and a consistent measurement procedure at each point.
Record the results so they can be compared later.
Do Not Measure Distance Alone
A common assumption is:
Closer to antenna = always higher RF reading
Actual RF environments can be more complicated.
The antenna's radiation pattern, direction, installation height, surrounding structures and other RF sources can all affect the measured field.
Therefore, two locations at similar distances from an antenna may produce different readings.
This is why direct field measurement can be useful when investigating a specific location.
Use MAX for Changing RF Levels
Telecommunications RF signals may vary with operating conditions.
If the displayed value changes during measurement, the MAX function can help capture a higher reading during the observation period.
This can be useful when comparing different measurement points.
For example:
Location A: normal + MAX
Location B: normal + MAX
Location C: normal + MAX
Using the same procedure at each location makes comparison more meaningful.
Use AVG for Longer Observations
A short peak reading does not necessarily describe the RF environment over an entire measurement period.
The AVG function can provide additional information about average RF field levels during the observation interval.
Depending on the purpose of the survey, users may record:
Current reading + MAX + AVG
However, the measurement duration and methodology should remain consistent when comparing locations.
Can TM-195 Identify Which Base Station Is Producing the Reading?
No.
The TENMARS TM-195 is a broadband RF field strength meter.
It measures the RF electromagnetic field present within its supported measurement range, but it does not identify individual operators, transmitters, channels or frequencies.
If several RF sources are present, the meter does not automatically separate them.
Applications requiring frequency-selective analysis or source identification may require a spectrum analyser or specialised RF measurement system.
Base Station Survey vs Spectrum Analysis
These are different measurement tasks.
If the requirement is:
“What is the broadband RF field strength at this location?”
A meter such as the TENMARS TM-195 may be suitable.
If the requirement is:
“Which frequency is producing this signal?”
or
“Which transmitter contributes how much RF energy?”
More specialised frequency-selective RF equipment may be required.
Understanding this difference helps avoid purchasing the wrong instrument.
RF Measurements Around Buildings
The TM-195 can also be used to compare RF levels at different areas of a building located near telecommunications equipment.
Possible measurement points include:
Ground floor
Upper floors
Rooftop accessible areas
Offices
Meeting rooms
Corridors
Windows
Outdoor accessible areas
Normal occupied work positions
Measurements should be taken systematically rather than simply searching for the highest number.
A simple location table can make later comparison easier.
RF Survey for Facility and Safety Teams
Facility management and safety teams may receive questions about wireless or telecommunications equipment installed near a workplace.
A basic RF field survey can help document measurements at selected locations.
A practical record may include:
Date → Time → Location → Measurement Unit → Current Reading → MAX → AVG → Equipment Operating Condition
This creates a more useful record than taking an undocumented spot reading.
Can TM-195 Be Used for RF Exposure Compliance Testing?
The distinction between a general RF survey and a formal compliance assessment is important.
The TM-195 can provide broadband RF field measurements within its supported specifications.
However, formal occupational, public exposure or regulatory assessments may specify particular standards, measurement procedures, averaging methods, calibration requirements, frequency response requirements and documentation.
Users carrying out compliance work should follow the applicable Malaysian regulations, standards or recognised assessment methodology.
A portable RF meter should not automatically be treated as sufficient for every regulatory compliance application.
Common Mistakes During Base Station RF Measurement
Avoid these common measurement mistakes:
Taking only one measurement
Measuring only directly underneath an antenna
Assuming distance alone determines RF level
Changing measurement units between locations
Blocking the sensor unnecessarily
Recording readings without location information
Ignoring changing transmitter conditions
Assuming a broadband meter identifies the exact frequency
Treating a general survey as a formal compliance assessment
A consistent measurement procedure produces more useful data.
Who May Use the TENMARS TM-195?
Potential users include:
Telecommunications technicians
Electrical contractors
Facility management teams
EHS and safety personnel
Building maintenance teams
RF equipment installers
Engineering consultants
Industrial maintenance teams
Technical service providers
The correct instrument should always be selected according to the actual RF source, frequency range and measurement objective.
TENMARS TM-195 for RF Field Measurement Malaysia
The TENMARS TM-195 provides portable 3-axis broadband RF field measurement from 50 MHz to 3.5 GHz.
It can be considered for general RF field surveys around compatible mobile communication, telecommunications, wireless and RF transmitting equipment.
If you are unsure whether the TM-195 is suitable, tell us:
What equipment are you measuring?
What frequency range is involved?
Do you need general field strength measurement or frequency identification?
MTM Precision can help you determine whether your application requires an RF field strength meter, EMF meter or more specialised RF test equipment.
Contact MTM Precision Sdn Bhd
Showroom & Service Centre: Puchong, Selangor, Malaysia
Operating Hours: Monday–Friday, 9:00 AM–6:00 PM
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Serving customers throughout Malaysia, including Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.
Keywords: TENMARS TM-195 Malaysia | RF Radiation Meter Malaysia | Mobile Base Station RF Measurement | RF Field Strength Meter Malaysia | Telecom RF Meter | 3-Axis RF Meter | RF Electromagnetic Field Measurement Malaysia
20 Sep 2026