How to Measure RF Power Density with TENMARS TM-195 Malaysia
How to Measure RF Power Density with TENMARS TM-195 Malaysia
Radio frequency fields are present around many types of wireless and telecommunications equipment.
Wi-Fi routers, wireless access points, communication antennas and RF transmitters can all generate RF electromagnetic fields during operation.
For technicians who need to check RF field levels at different locations, the TENMARS TM-195 3-Axis RF Field Strength Meter provides a practical portable measurement solution.
The TM-195 is designed for broadband RF measurements from 50 MHz to 3.5 GHz.
What Is RF Power Density?
RF power density is one way of describing the strength of a radio frequency electromagnetic field at a measurement location.
Depending on the instrument and measurement requirement, RF fields can be displayed using different measurement units.
The important point for practical field work is to use a consistent unit when comparing different locations.
For example, if you measure five locations inside an office, use the same measurement unit for all five points.
This makes the results easier to compare.
What Can the TENMARS TM-195 Measure?
The TENMARS TM-195 is designed to measure broadband RF electromagnetic fields.
It can be used for general RF field surveys around compatible sources such as:
Wi-Fi routers
Wireless access points
RF transmitters
Telecommunications equipment
Communication antennas
Wireless communication devices
Commercial wireless installations
Other compatible RF sources
Before taking measurements, always confirm that the source you want to investigate operates within the supported frequency range of the meter.
TENMARS TM-195 Frequency Range
The TM-195 covers:
50 MHz to 3.5 GHz
This is an important specification.
Not every wireless technology operates within the same frequency range, and one RF meter should not automatically be assumed to cover every RF application.
Before purchasing an RF meter, identify the operating frequency of the equipment you want to measure.
Step 1 - Identify the RF Source
Start by identifying the suspected RF source.
Ask:
What equipment am I trying to measure?
For example, the source may be a Wi-Fi access point, telecommunications antenna or RF transmitter.
Knowing the source helps determine where measurements should be taken.
Step 2 - Select a Reference Location
Do not begin by measuring only beside the RF source.
First select a reference point.
This could be a normal occupied position or an area farther away from the suspected source.
Record the measurement.
You can then move progressively toward other locations.
Step 3 - Measure at Several Locations
A single RF reading provides limited information.
A better survey may include:
Point A - Reference location
Point B - Normal working position
Point C - Middle of the room
Point D - Closer to the RF source
Point E - Another direction from the RF source
Record the reading at every point.
This provides a simple picture of how the RF field changes across the area.
Step 4 - Keep the Meter Position Consistent
Measurement technique can affect the results.
When comparing several locations:
Keep the meter reasonably steady
Use a similar measurement height
Avoid covering the sensor
Avoid unnecessarily blocking the RF source with your body
Use a similar observation time
Use the same measurement unit
Consistency is important when comparing RF measurements.
Step 5 - Observe the Reading
RF fields may fluctuate.
Do not assume that the first number displayed is the final result.
Observe the meter for a period of time.
The reading may increase or decrease depending on wireless activity, transmitter operation and surrounding conditions.
This is normal in many RF environments.
Why Do RF Readings Change?
RF field measurements can be affected by many factors.
These include:
Distance from the RF source
Antenna direction
Wireless traffic
Transmitter operating condition
Walls
Building structures
Metal surfaces
Other RF sources
Reflections
Movement of people
Meter position
For this reason, RF measurements inside real buildings may not change smoothly as you move away from the source.
Using MAX for RF Measurements
The MAX function is useful when RF levels fluctuate.
It allows the user to observe a higher measured value during the measurement period.
For example, a technician can record:
Location A - Normal Reading and MAX
Location B - Normal Reading and MAX
Location C - Normal Reading and MAX
This can be useful when comparing several locations.
Using AVG for RF Measurements
The AVG function can provide additional information when the RF field changes over time.
Instead of looking only at a short peak, AVG helps users observe the average measurement during the selected measurement period.
When comparing locations, use a consistent observation time where possible.
Why Use a 3-Axis RF Meter?
RF fields can arrive from different directions.
This is particularly common inside buildings where signals may come from several wireless sources or be affected by surrounding structures.
The TENMARS TM-195 uses a 3-axis RF measurement system.
This reduces the need to repeatedly rotate the meter to search for a particular field direction.
It is useful for practical RF surveys where the direction of the RF source may not always be obvious.
Example - Measuring RF Around a Wi-Fi Access Point
Consider an office with a wireless access point.
A simple survey could include:
Location 1 - Workstation
Location 2 - Meeting table
Location 3 - Middle of office
Location 4 - Near wireless access point
Location 5 - Corridor outside office
Take measurements at each location using the same procedure.
This provides more useful information than measuring only directly beside the access point.
Example - Measuring RF Around Telecom Equipment
The same method can be used around compatible telecommunications equipment.
Select several accessible measurement points.
For example:
Reference area -> Occupied area -> Intermediate position -> Near equipment
Record the measurements and compare them.
If the readings fluctuate, MAX and AVG functions can provide additional information.
Can TM-195 Identify the Exact Frequency?
No.
The TENMARS TM-195 is a broadband RF field strength meter.
It measures RF electromagnetic field strength within its supported frequency range.
It is not designed to identify the exact individual frequency producing a particular reading.
If several RF sources are operating in the same area, the meter does not automatically separate them.
For detailed frequency identification, specialised RF test equipment such as a spectrum analyser may be required.
RF Field Meter or Spectrum Analyser?
The correct instrument depends on the question you need to answer.
If your question is:
How strong is the RF field at this location?
A broadband RF field strength meter may be suitable.
If your question is:
Which exact frequency is producing this signal?
A spectrum analyser or other frequency-selective instrument may be required.
These are different measurement applications.
Can TM-195 Be Used for Formal RF Compliance Testing?
The TM-195 can provide broadband RF field measurements within its specified operating range.
However, formal RF exposure or regulatory assessments may require specific:
Measurement procedures
Applicable standards
Averaging methods
Instrument specifications
Calibration requirements
Documentation
A general RF spot measurement should not automatically be treated as a formal compliance assessment.
Users carrying out regulatory or occupational exposure work should follow the applicable requirements for the project.
Common RF Measurement Mistakes
Avoid these common mistakes:
Taking only one measurement
Measuring without knowing the RF source
Ignoring the frequency range of the meter
Changing measurement units between locations
Blocking the sensor
Measuring at inconsistent positions
Assuming the closest point must always have the highest reading
Expecting a broadband meter to identify individual frequencies
Treating a general RF survey as a formal compliance test
A structured measurement method provides more useful results.
Who May Need the TENMARS TM-195?
The TENMARS TM-195 may be useful for:
Telecommunications technicians
RF equipment installers
Electrical contractors
Facility management teams
EHS personnel
Maintenance departments
Engineering consultants
Commercial building maintenance teams
Industrial facilities
General RF field surveys
The correct meter should always be selected according to the RF source, operating frequency and measurement objective.
TENMARS TM-195 RF Field Strength Meter Malaysia
The TENMARS TM-195 3-Axis RF Field Strength Meter is designed for portable broadband RF electromagnetic field measurement from 50 MHz to 3.5 GHz.
It can be considered for general RF surveys around compatible wireless, telecommunications and RF transmitting equipment.
Not sure whether the TM-195 is suitable?
Tell MTM Precision:
What equipment do you want to measure?
What is the operating frequency?
Do you need general RF field measurement or detailed frequency analysis?
We can help you select the appropriate test instrument for your application.
Contact MTM Precision Sdn Bhd
Showroom & Service Centre: Puchong, Selangor, Malaysia
Operating Hours: Monday-Friday, 9:00 AM-6:00 PM
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Serving customers throughout Malaysia, including Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.
Keywords: TENMARS TM-195 Malaysia | RF Power Density Meter Malaysia | RF Field Strength Meter Malaysia | 3-Axis RF Meter | RF Measurement Malaysia | Telecom RF Meter | Wireless RF Testing Malaysia
20 Sep 2026