TENMARS TM-195 50MHz-3.5GHz Frequency Range Explained Malaysia
TENMARS TM-195 50MHz-3.5GHz Frequency Range Explained Malaysia
One of the most important specifications when choosing an RF field strength meter is its frequency range.
The TENMARS TM-195 3-Axis RF Field Strength Meter is designed for broadband RF electromagnetic field measurements from:
50 MHz to 3.5 GHz
But what does this specification actually mean?
Understanding the frequency range is important because not every RF meter can measure every type of wireless signal.
Before purchasing an RF meter, users should first identify the frequency of the equipment they want to investigate.
What Does 50 MHz to 3.5 GHz Mean?
MHz means megahertz.
GHz means gigahertz.
The TM-195 is designed to respond to RF electromagnetic fields within its specified frequency range from 50 MHz up to 3.5 GHz.
This makes it suitable for general RF field surveys involving compatible wireless, telecommunications and RF transmitting equipment.
However, the frequency range should always be checked against the actual RF source.
Why Is Frequency Range Important?
An RF meter can only be expected to perform according to its specified frequency response.
For example, if a customer says:
"I want to measure a wireless transmitter."
That information alone is not enough.
The next question should be:
"What frequency does the transmitter operate at?"
If the operating frequency falls within the supported range of the TM-195, the instrument may be suitable for general broadband RF field measurement.
If the frequency is outside the supported range, another RF instrument should be considered.
What Types of Applications May Be Within the TM-195 Range?
Depending on the actual operating frequency, possible applications can include general RF surveys around:
Wireless communication equipment
Wi-Fi equipment operating within the supported range
RF transmitters
Telecommunications equipment
Communication antennas
Commercial wireless systems
Industrial wireless equipment
Other RF sources within 50 MHz to 3.5 GHz
Always check the actual equipment frequency before confirming suitability.
Can TM-195 Measure Wi-Fi?
For Wi-Fi measurement, frequency matters.
Some commonly encountered Wi-Fi systems operate within frequency bands that fall inside the TM-195 measurement range.
For these compatible systems, the TM-195 can be used for general RF field strength measurements.
For example, users can compare readings:
Near access point -> Workstation -> Meeting room -> Corridor
However, modern Wi-Fi technology can also operate at frequencies above the TM-195 upper frequency limit.
Therefore, do not assume that the TM-195 covers every Wi-Fi frequency simply because the application is called "Wi-Fi."
Always confirm the actual frequency band first.
Can TM-195 Measure 5 GHz Wi-Fi?
The TM-195 has an upper specified frequency of 3.5 GHz.
Therefore, a 5 GHz Wi-Fi signal is outside its specified frequency range.
If the main purpose is specifically to measure RF fields from a 5 GHz Wi-Fi system, a meter with a suitable higher frequency range should be selected.
This is an important consideration when choosing an RF meter for modern wireless environments.
Can TM-195 Measure Mobile Communication Signals?
The answer depends on the actual frequency involved.
Mobile communication systems can use different frequency bands.
Some may fall within the TM-195 frequency range, while others may not.
Therefore, the correct approach is not simply to ask:
"Can TM-195 measure mobile signals?"
Instead ask:
"What frequency band do I need to measure?"
Once the frequency is known, it can be compared with the meter specification.
Can TM-195 Measure RF Around a Base Station?
The TM-195 may be used for general broadband RF field surveys around compatible telecommunications equipment when the frequencies of interest fall within its supported range.
Measurements can be taken at several locations, such as:
Reference location
Normal occupied area
Intermediate location
Closer accessible location
The readings can then be compared.
For formal RF exposure or regulatory assessments, users should also confirm the applicable standards, measurement procedure and instrument requirements.
Can TM-195 Measure Microwave Oven RF?
Microwave ovens commonly operate around 2.45 GHz, which falls within the TM-195 frequency range.
The TM-195 can therefore detect RF fields associated with this frequency range.
However, a general broadband RF field strength meter should not automatically be treated as a replacement for a dedicated microwave leakage tester when a specific test method or compliance requirement applies.
The measurement objective should determine the instrument.
Can TM-195 Measure Low-Frequency Electrical Fields?
The TM-195 is designed for radio-frequency electromagnetic field measurement.
It should not be selected simply because an application involves the word "electromagnetic."
For example, customers investigating electromagnetic fields around:
Power cables
Transformers
Electrical switchboards
Motors
Low-frequency electrical equipment
may require a different type of EMF meter.
RF measurement and low-frequency electric or magnetic field measurement are different applications.
Can TM-195 Measure Frequencies Above 3.5 GHz?
The specified upper frequency of the TM-195 is 3.5 GHz.
If the RF source operates above this range, another instrument with appropriate frequency coverage should be selected.
Do not assume that the meter will provide a valid measurement simply because a number appears on the display.
Instrument selection should always follow the manufacturer's specified measurement range.
Frequency Range Does Not Mean Frequency Identification
Another important point is that:
50 MHz to 3.5 GHz does not mean the TM-195 displays the exact frequency being measured.
The TM-195 is a broadband RF field strength meter.
It measures RF electromagnetic field strength within its supported range.
It is not a spectrum analyser.
For example, if several compatible RF sources are operating simultaneously, the TM-195 does not automatically show:
Source A = specific frequency
Source B = specific frequency
Source C = specific frequency
Detailed frequency identification requires different RF test equipment.
Broadband RF Meter vs Spectrum Analyser
These instruments answer different questions.
Use a broadband RF field strength meter when your main question is:
"How strong is the RF field at this location?"
A spectrum analyser or frequency-selective instrument may be required when your question is:
"Which exact frequency is producing this signal?"
or:
"Which transmitter is responsible for this RF signal?"
Understanding this difference helps prevent incorrect instrument selection.
Why Does TM-195 Use a 3-Axis Sensor?
RF fields may arrive from different directions.
Inside buildings, RF signals may also be affected by reflections from walls, equipment and metal structures.
The 3-axis measurement system of the TM-195 makes general RF field surveys more convenient when the direction of the field is unknown.
This is particularly useful when several wireless or RF sources are present in the same environment.
How to Check Whether TM-195 Is Suitable
Before buying the TM-195, answer these four questions:
1. What equipment do you want to measure?
Example: Wi-Fi access point, RF transmitter or telecommunications equipment.
2. What is the operating frequency?
Compare it with the TM-195 range of 50 MHz to 3.5 GHz.
3. What do you want to know?
Do you need general RF field strength or detailed frequency identification?
4. Is this a general survey or formal compliance measurement?
Formal assessments may require additional standards and instrument requirements.
These four questions can quickly determine whether the TM-195 is appropriate.
Example 1 - Office Wi-Fi Survey
A customer wants to compare RF field levels around an office wireless access point.
First check the operating frequency.
If the frequency is within the TM-195 supported range, measurements can be taken at:
Access point area -> Workstation -> Meeting room -> Corridor
The readings can then be compared using a consistent measurement method.
Example 2 - RF Transmitter
A technician wants to check the RF field around a transmitter.
Before recommending the TM-195, identify the transmitter frequency.
If the frequency falls within 50 MHz to 3.5 GHz, the TM-195 may be considered for general broadband field measurements.
If the technician needs to identify the exact transmitted frequency or analyse the signal spectrum, another RF instrument may be required.
Example 3 - Unknown RF Source
Sometimes a customer says:
"There is an RF source here, but I don't know the frequency."
In this situation, selecting a meter based only on the suspected source can be risky.
Try to identify the equipment specification first.
If the frequency cannot be determined and frequency identification itself is the objective, a different RF measurement approach may be necessary.
Who May Use the TENMARS TM-195?
The TM-195 may be considered by:
Telecommunications technicians
Electrical contractors
RF equipment installers
Facility management teams
EHS personnel
Maintenance departments
Engineering consultants
Building maintenance teams
Industrial technical teams
The most important step is matching the instrument frequency range to the application.
TENMARS TM-195 RF Field Strength Meter Malaysia
The TENMARS TM-195 offers portable 3-axis broadband RF field measurement from 50 MHz to 3.5 GHz.
The frequency range makes it suitable for many general RF measurement applications, but it does not cover every modern wireless frequency.
Before ordering, tell MTM Precision:
What equipment do you want to measure?
What is its operating frequency?
Do you need field strength measurement or frequency identification?
This information allows us to check whether the TM-195 is suitable before you purchase.
Contact MTM Precision Sdn Bhd
Showroom & Service Centre: Puchong, Selangor, Malaysia
Operating Hours: Monday-Friday, 9:00 AM-6:00 PM
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Serving customers throughout Malaysia, including Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.
Keywords: TENMARS TM-195 Malaysia | 50MHz-3.5GHz RF Meter | RF Frequency Range Malaysia | RF Field Strength Meter Malaysia | 3-Axis RF Meter | Wi-Fi RF Meter Malaysia | Telecom RF Meter Malaysia
20 Sep 2026