TASI TA813B+ for VFD and Motor Troubleshooting Malaysia

TASI TA813B+ for VFD and Motor Troubleshooting Malaysia

 

Variable Frequency Drives (VFDs) are widely used to control motors in factories, HVAC systems, pumps, fans, compressors and automated machinery.

 

When a VFD-driven motor develops a problem, checking only whether power is present may not provide enough information.

 

Technicians often need to investigate different sections of the system:

 

Power Supply → VFD → Motor → Mechanical Load

 

The TASI TA813B+ True RMS Digital Clamp Meter provides functions such as True RMS, VFD voltage measurement, AC/DC current measurement and frequency measurement, making it a useful instrument for electrical maintenance and VFD-related troubleshooting.

 

What Is a VFD?

 

A Variable Frequency Drive controls an AC motor by changing the electrical frequency and voltage supplied to the motor.

 

VFDs are commonly used where motor speed needs to be controlled according to operating demand.

 

Typical applications include:

 

Water pumps

 

Cooling tower fans

 

AHU systems

 

Ventilation fans

 

Air compressors

 

Conveyors

 

Production machinery

 

Process equipment

 

Industrial automation

 

For example, a pump does not necessarily need to operate at full speed continuously.

 

A VFD allows the system to adjust motor speed according to process requirements.

 

Why Can VFD Troubleshooting Be Different?

 

The output waveform from a VFD is different from a conventional mains sine-wave supply.

 

This can make electrical measurements more challenging.

 

When investigating a VFD system, technicians may need to determine whether the problem is associated with:

 

Incoming Supply

 

↓

 

VFD

 

↓

 

Motor

 

↓

 

Driven Equipment

 

Without systematic measurements, it can be easy to replace a component before identifying the actual source of the problem.

 

TASI TA813B+ VFD Voltage Function

 

The TA813B+ includes a dedicated VFD voltage measurement function.

 

This feature is designed for applications involving variable frequency drives and other motor-control systems.

 

For maintenance technicians working regularly with pumps, fans, compressors and industrial motors, this is one of the more relevant features of the TA813B+.

 

Instead of treating it only as a general-purpose clamp meter, the TA813B+ can form part of a broader VFD troubleshooting toolkit.

 

Step 1: Check the Incoming Power Supply

 

When a VFD-controlled motor stops operating correctly, the first area to investigate is often the supply side.

 

Questions may include:

 

Is the expected voltage reaching the VFD?

 

Is there an obvious supply problem?

 

Is the protective device operating normally?

 

Is there an abnormal condition upstream?

 

A technician can perform appropriate voltage measurements according to the equipment design and applicable electrical safety procedures.

 

This helps separate:

 

Supply Problem

 

from

 

VFD / Motor Problem

 

Step 2: Check the VFD

 

If the incoming supply appears normal, attention can move toward the VFD.

 

Depending on the fault and equipment, technicians may consider:

 

VFD display or fault code

 

Input voltage

 

Output condition

 

Operating frequency

 

Motor current

 

Control signals

 

Connections

 

The clamp meter does not replace the VFD manufacturer's diagnostic procedures, but electrical measurements can provide useful supporting information.

 

Step 3: Check Motor Current

 

Current measurement is particularly useful when troubleshooting motors.

 

The clamp should be used on the appropriate individual conductor, following correct electrical measurement procedures.

 

Technicians can check whether the motor is drawing current and compare measurements with:

 

Motor nameplate information

 

Equipment specifications

 

Historical readings

 

Similar machines

 

Normal operating conditions

 

An unusual current reading does not automatically identify the cause, but it gives the technician another piece of evidence.

 

VFD Motor Running but Current Is High

 

Suppose a factory reports:

 

“The motor is still running, but the current is higher than before.”

 

Possible areas requiring investigation can include:

 

Mechanical loading

 

Motor condition

 

Pump condition

 

Bearing condition

 

Alignment

 

Process load

 

Electrical supply

 

VFD parameters

 

Motor connection

 

This illustrates why clamp-meter measurements should be combined with other maintenance information.

 

A current reading tells you what is happening electrically.

 

Further troubleshooting is required to determine why it is happening.

 

VFD Motor Not Reaching Normal Speed

 

Another common complaint is:

 

“The motor runs, but it cannot reach the expected speed.”

 

The troubleshooting path may include:

 

Supply → VFD Settings → Output Frequency → Motor → Mechanical Load

 

Checking frequency and electrical conditions can help technicians determine which part of the system deserves further investigation.

 

VFD Trips During Operation

 

A VFD trip can have many possible causes.

 

Depending on the drive and application, technicians may investigate:

 

Overcurrent

 

Overload

 

Supply problems

 

Motor problems

 

Mechanical load

 

Cooling problems

 

Wiring

 

Incorrect parameters

 

Ground-related faults

 

The first step should normally include checking the actual VFD fault code and manufacturer's documentation.

 

Electrical measurements can then be used to support the troubleshooting process.

 

TA813B+ for Pump Maintenance

 

Pumps are one of the strongest applications for VFD electrical troubleshooting.

 

A typical industrial system may look like:

 

Power Supply → VFD → Motor → Pump → Process

 

If pump performance deteriorates, the cause is not necessarily electrical.

 

For example, technicians may need to investigate both electrical and mechanical conditions.

 

Useful measurements may include:

 

Voltage + Frequency + Current + Vibration + Process Condition

 

This is particularly relevant for preventive maintenance teams.

 

TA813B+ for HVAC Maintenance

 

Modern HVAC systems frequently use VFDs for:

 

Chilled-water pumps

 

Cooling tower fans

 

AHU fans

 

Ventilation systems

 

Variable-speed compressors

 

Building mechanical systems

 

The TA813B+ can therefore be relevant to HVAC technicians who need a clamp meter for both conventional electrical checks and VFD-related work.

 

Its temperature measurement capability also adds another useful function for general HVAC maintenance.

 

TA813B+ for Factory Motors

 

Factories may have dozens or hundreds of motors.

 

Rather than waiting for a motor to stop completely, maintenance teams can establish baseline electrical readings for important machines.

 

For example:

 

EquipmentCurrentFrequencyVoltageConditionPump Motor 01RecordRecordRecordNormalExhaust Fan 02RecordRecordRecordNormalCompressor 01RecordRecordRecordNormalCooling Tower FanRecordRecordRecordNormal

 

During later inspections, technicians can compare new readings against the baseline.

 

A significant change can trigger further investigation.

 

Combine Electrical and Vibration Testing

 

For rotating machinery, electrical measurements become more useful when combined with mechanical-condition measurements.

 

For example:

 

Clamp Meter

 

Current → Voltage → Frequency → Electrical behaviour

 

Vibration Meter

 

Vibration → Mechanical behaviour

 

A motor drawing unusual current together with increasing vibration gives the maintenance team more information than either measurement alone.

 

This is especially useful for:

 

Pumps

 

Motors

 

Fans

 

Blowers

 

Compressors

 

Cooling towers

 

Why TA813B+ Fits Factory Maintenance

 

The TA813B+ combines several functions relevant to industrial electrical troubleshooting:

 

True RMS + AC/DC Current + VFD Voltage + Inrush Current + Frequency + High/Low-Z + Temperature

 

This makes it suitable for technicians who encounter different types of electrical systems rather than performing only one measurement task.

 

Applications can include:

 

Motor Maintenance → VFD Troubleshooting → HVAC → Pumps → Compressors → Factory Preventive Maintenance

 

Important Measurement Safety

 

VFD and motor systems can involve hazardous voltages and high-energy electrical circuits.

 

Measurements should only be performed by appropriately trained personnel using suitable procedures and personal protective equipment.

 

Always verify:

 

Instrument measurement category

 

Voltage and current limits

 

Test lead ratings

 

Equipment condition

 

Applicable electrical safety procedures

 

Never rely on a clamp meter alone to determine whether equipment is safe to touch or service.

 

TASI TA813B+ VFD Clamp Meter Supplier Malaysia

 

For enquiries about the TASI TA813B+ True RMS Digital Clamp Meter for VFD, motor, pump, HVAC and factory maintenance applications, contact:

 

MTM Precision Sdn Bhd

 

Showroom & Service Centre

No 29-1 & 2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Tel: 03-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com

Website: www.mtmpre.com.my

 

Supporting customers across Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.


 

26 Sep 2026