TASI TA813B+ for VFD and Motor Troubleshooting Malaysia
TASI TA813B+ for VFD and Motor Troubleshooting Malaysia
Variable Frequency Drives (VFDs) are widely used to control motors in factories, HVAC systems, pumps, fans, compressors and automated machinery.
When a VFD-driven motor develops a problem, checking only whether power is present may not provide enough information.
Technicians often need to investigate different sections of the system:
Power Supply → VFD → Motor → Mechanical Load
The TASI TA813B+ True RMS Digital Clamp Meter provides functions such as True RMS, VFD voltage measurement, AC/DC current measurement and frequency measurement, making it a useful instrument for electrical maintenance and VFD-related troubleshooting.
What Is a VFD?
A Variable Frequency Drive controls an AC motor by changing the electrical frequency and voltage supplied to the motor.
VFDs are commonly used where motor speed needs to be controlled according to operating demand.
Typical applications include:
Water pumps
Cooling tower fans
AHU systems
Ventilation fans
Air compressors
Conveyors
Production machinery
Process equipment
Industrial automation
For example, a pump does not necessarily need to operate at full speed continuously.
A VFD allows the system to adjust motor speed according to process requirements.
Why Can VFD Troubleshooting Be Different?
The output waveform from a VFD is different from a conventional mains sine-wave supply.
This can make electrical measurements more challenging.
When investigating a VFD system, technicians may need to determine whether the problem is associated with:
Incoming Supply
↓
VFD
↓
Motor
↓
Driven Equipment
Without systematic measurements, it can be easy to replace a component before identifying the actual source of the problem.
TASI TA813B+ VFD Voltage Function
The TA813B+ includes a dedicated VFD voltage measurement function.
This feature is designed for applications involving variable frequency drives and other motor-control systems.
For maintenance technicians working regularly with pumps, fans, compressors and industrial motors, this is one of the more relevant features of the TA813B+.
Instead of treating it only as a general-purpose clamp meter, the TA813B+ can form part of a broader VFD troubleshooting toolkit.
Step 1: Check the Incoming Power Supply
When a VFD-controlled motor stops operating correctly, the first area to investigate is often the supply side.
Questions may include:
Is the expected voltage reaching the VFD?
Is there an obvious supply problem?
Is the protective device operating normally?
Is there an abnormal condition upstream?
A technician can perform appropriate voltage measurements according to the equipment design and applicable electrical safety procedures.
This helps separate:
Supply Problem
from
VFD / Motor Problem
Step 2: Check the VFD
If the incoming supply appears normal, attention can move toward the VFD.
Depending on the fault and equipment, technicians may consider:
VFD display or fault code
Input voltage
Output condition
Operating frequency
Motor current
Control signals
Connections
The clamp meter does not replace the VFD manufacturer's diagnostic procedures, but electrical measurements can provide useful supporting information.
Step 3: Check Motor Current
Current measurement is particularly useful when troubleshooting motors.
The clamp should be used on the appropriate individual conductor, following correct electrical measurement procedures.
Technicians can check whether the motor is drawing current and compare measurements with:
Motor nameplate information
Equipment specifications
Historical readings
Similar machines
Normal operating conditions
An unusual current reading does not automatically identify the cause, but it gives the technician another piece of evidence.
VFD Motor Running but Current Is High
Suppose a factory reports:
“The motor is still running, but the current is higher than before.”
Possible areas requiring investigation can include:
Mechanical loading
Motor condition
Pump condition
Bearing condition
Alignment
Process load
Electrical supply
VFD parameters
Motor connection
This illustrates why clamp-meter measurements should be combined with other maintenance information.
A current reading tells you what is happening electrically.
Further troubleshooting is required to determine why it is happening.
VFD Motor Not Reaching Normal Speed
Another common complaint is:
“The motor runs, but it cannot reach the expected speed.”
The troubleshooting path may include:
Supply → VFD Settings → Output Frequency → Motor → Mechanical Load
Checking frequency and electrical conditions can help technicians determine which part of the system deserves further investigation.
VFD Trips During Operation
A VFD trip can have many possible causes.
Depending on the drive and application, technicians may investigate:
Overcurrent
Overload
Supply problems
Motor problems
Mechanical load
Cooling problems
Wiring
Incorrect parameters
Ground-related faults
The first step should normally include checking the actual VFD fault code and manufacturer's documentation.
Electrical measurements can then be used to support the troubleshooting process.
TA813B+ for Pump Maintenance
Pumps are one of the strongest applications for VFD electrical troubleshooting.
A typical industrial system may look like:
Power Supply → VFD → Motor → Pump → Process
If pump performance deteriorates, the cause is not necessarily electrical.
For example, technicians may need to investigate both electrical and mechanical conditions.
Useful measurements may include:
Voltage + Frequency + Current + Vibration + Process Condition
This is particularly relevant for preventive maintenance teams.
TA813B+ for HVAC Maintenance
Modern HVAC systems frequently use VFDs for:
Chilled-water pumps
Cooling tower fans
AHU fans
Ventilation systems
Variable-speed compressors
Building mechanical systems
The TA813B+ can therefore be relevant to HVAC technicians who need a clamp meter for both conventional electrical checks and VFD-related work.
Its temperature measurement capability also adds another useful function for general HVAC maintenance.
TA813B+ for Factory Motors
Factories may have dozens or hundreds of motors.
Rather than waiting for a motor to stop completely, maintenance teams can establish baseline electrical readings for important machines.
For example:
EquipmentCurrentFrequencyVoltageConditionPump Motor 01RecordRecordRecordNormalExhaust Fan 02RecordRecordRecordNormalCompressor 01RecordRecordRecordNormalCooling Tower FanRecordRecordRecordNormal
During later inspections, technicians can compare new readings against the baseline.
A significant change can trigger further investigation.
Combine Electrical and Vibration Testing
For rotating machinery, electrical measurements become more useful when combined with mechanical-condition measurements.
For example:
Clamp Meter
Current → Voltage → Frequency → Electrical behaviour
Vibration Meter
Vibration → Mechanical behaviour
A motor drawing unusual current together with increasing vibration gives the maintenance team more information than either measurement alone.
This is especially useful for:
Pumps
Motors
Fans
Blowers
Compressors
Cooling towers
Why TA813B+ Fits Factory Maintenance
The TA813B+ combines several functions relevant to industrial electrical troubleshooting:
True RMS + AC/DC Current + VFD Voltage + Inrush Current + Frequency + High/Low-Z + Temperature
This makes it suitable for technicians who encounter different types of electrical systems rather than performing only one measurement task.
Applications can include:
Motor Maintenance → VFD Troubleshooting → HVAC → Pumps → Compressors → Factory Preventive Maintenance
Important Measurement Safety
VFD and motor systems can involve hazardous voltages and high-energy electrical circuits.
Measurements should only be performed by appropriately trained personnel using suitable procedures and personal protective equipment.
Always verify:
Instrument measurement category
Voltage and current limits
Test lead ratings
Equipment condition
Applicable electrical safety procedures
Never rely on a clamp meter alone to determine whether equipment is safe to touch or service.
TASI TA813B+ VFD Clamp Meter Supplier Malaysia
For enquiries about the TASI TA813B+ True RMS Digital Clamp Meter for VFD, motor, pump, HVAC and factory maintenance applications, contact:
MTM Precision Sdn Bhd
Showroom & Service Centre
No 29-1 & 2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Supporting customers across Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.
26 Sep 2026