How to Measure DC Current with TASI TA813B+ Clamp Meter Malaysia
How to Measure DC Current with TASI TA813B+ Clamp Meter Malaysia
Measuring DC current does not always require disconnecting a circuit and inserting a conventional multimeter in series.
With a suitable AC/DC clamp meter such as the TASI TA813B+, technicians can measure DC current by clamping around the appropriate conductor.
This makes the TA813B+ particularly useful for technicians working with battery systems, DC power supplies, industrial control systems, automation equipment and renewable energy applications.
Why Is DC Current Measurement Useful?
Many people associate clamp meters mainly with AC electrical systems.
However, modern industrial and electrical installations can contain both AC and DC circuits.
Examples include:
Battery systems
DC power supplies
Industrial control systems
Automation equipment
Backup power systems
Renewable energy equipment
DC motors
Control panels
Automotive and machinery electrical systems
For technicians who regularly encounter both types of circuits, an AC/DC current clamp meter can provide greater measurement flexibility.
TA813B+ vs TA813A+ for DC Current
One important difference within the TASI TA813 Series is DC current measurement.
The TA813B+ supports DC current measurement, while the TA813A+ is intended for applications where this additional capability is not required.
The TA813B+ also provides DC Zero Adjustment, which is particularly relevant before performing DC clamp-current measurements.
For technicians working only with conventional AC systems, TA813A+ may cover many routine tasks.
For technicians who encounter:
AC Systems + DC Systems
the TA813B+ provides the broader measurement capability.
How Does a Clamp Meter Measure DC Current?
A clamp meter detects the magnetic field associated with current flowing through a conductor.
For current measurement, the clamp must be positioned around the appropriate single conductor.
For example:
DC Source (+) → Load → DC Source (-)
The clamp is placed around one conductor carrying the current.
If both positive and negative conductors are enclosed together, their magnetic fields can oppose each other and affect the measurement.
This is one of the most important points when using a clamp meter.
Step 1: Identify the Circuit
Before measuring, determine:
Is the circuit AC or DC?
What current level is expected?
Which conductor should be measured?
Is the expected value within the meter's measurement range?
Is the measurement safe to perform?
Do not start by simply clamping onto any available cable.
Understanding the circuit comes first.
Step 2: Select DC Current Measurement
Set the TASI TA813B+ to the appropriate DC current measurement mode.
Confirm the meter is configured correctly before placing the clamp around the conductor.
Step 3: Perform DC Zero Adjustment
DC clamp-current measurements can be affected by residual magnetic fields and sensor offset.
The TA813B+ provides DC Zero Adjustment to compensate for this before measurement.
With the clamp closed and positioned appropriately away from the conductor being measured, perform the zero adjustment according to the manufacturer's operating procedure.
This establishes a better reference point for the measurement.
Step 4: Clamp One Conductor
Open the clamp jaw and place it around the appropriate single conductor.
Avoid clamping both outgoing and return conductors together.
Keep the conductor positioned appropriately within the clamp according to the instrument instructions.
Step 5: Read the DC Current
Once the reading stabilizes, record the measured current.
The value can then be compared with:
Equipment specifications
Expected load
Previous readings
Similar equipment
Normal operating conditions
A current reading is most useful when there is something meaningful to compare it against.
Example: DC Power Supply Troubleshooting
Industrial control panels commonly use DC power supplies.
A simplified system may look like:
AC Supply → DC Power Supply → 24V DC Control System → PLC / Sensors / Relays
Suppose a machine experiences intermittent control problems.
A technician may need to investigate:
AC input
DC output voltage
DC load current
Wiring
Power supply condition
Connected equipment
DC current measurement provides another useful data point when evaluating the system.
Example: Battery System
Consider a battery supplying a DC load:
Battery → Protection → DC Load
The TA813B+ can be used to check current flowing through an accessible individual conductor, provided the application is within the instrument's specifications.
Possible applications include checking:
Load current
Current changes when equipment starts
Differences between operating conditions
Unexpected current consumption
Current measurement should always be interpreted together with voltage, battery condition and the design of the system.
TA813B+ for Solar and Renewable Energy
Renewable energy systems can contain both DC and AC sections.
A simplified solar system may contain:
PV / DC Source
↓
DC Circuit
↓
Inverter
↓
AC Circuit
↓
Electrical Load
This is one reason an AC/DC clamp meter can be useful for technicians working around renewable-energy equipment.
The same instrument can support current measurements on different parts of a system, subject to the meter's specified ratings and the equipment manufacturer's procedures.
TA813B+ for Industrial Automation
Automation equipment frequently combines conventional AC power with DC control circuits.
For example:
AC Power
↓
Power Supply
↓
24V DC
↓
PLC + Sensors + Relays + Control Devices
A technician who only has an AC current clamp meter cannot perform the same type of clamp-current measurement on the DC side.
The TA813B+ therefore provides additional flexibility for industrial maintenance technicians working across both power and control systems.
Why DC Zero Matters
DC current measurement differs from routine AC clamp measurement because the sensor can retain or detect an offset even when no current-carrying conductor is inside the jaw.
If the meter shows a small reading before the actual measurement, that offset can influence the final result.
This is why DC Zero Adjustment is an important companion feature to DC current measurement.
A simple concept is:
Close Clamp → Zero → Clamp Conductor → Measure
Always follow the manufacturer's instructions for the actual measurement procedure.
Common Mistake: Clamping the Whole Cable
A common mistake is to clamp around a cable containing both the positive and negative current paths.
For example:
+ Conductor → Load
- Conductor ← Load
If both are inside the clamp simultaneously, the opposing magnetic fields can cancel substantially.
This may result in a very low or misleading reading.
For normal current measurement, isolate and clamp the appropriate single conductor.
Common Mistake: Forgetting DC Zero
Another mistake is immediately taking a DC current reading without checking the meter's zero condition.
If an offset is present, it can affect the measurement.
This becomes especially important when the actual current being measured is relatively small compared with the meter's total measurement range.
DC Current Direction
DC current has direction.
Depending on clamp orientation and current flow, the instrument may indicate current polarity or direction through the displayed result.
If the reading appears with the opposite polarity from expected, check:
Clamp orientation
Current direction
Circuit polarity
Do not automatically assume the circuit itself has a fault.
DC Current vs DC Voltage
These measurements answer different questions.
DC Voltage
Shows the electrical potential difference between two points.
DC Current
Shows the current flowing through the circuit conductor.
A system can show apparently normal voltage while behaving differently under load.
For troubleshooting, technicians may therefore need to examine both:
Voltage + Current
rather than relying on only one measurement.
Building a DC Maintenance Baseline
For important equipment, technicians can record normal operating measurements.
For example:
EquipmentDC VoltageDC CurrentConditionControl Panel ARecordRecordNormalDC Power Supply BRecordRecordNormalBattery System CRecordRecordNormalMachine Control DRecordRecordNormal
When a problem occurs later, the new measurement can be compared against the previous baseline.
This is generally more useful than trying to interpret an isolated reading without historical information.
Why TA813B+ Is Useful for Mixed AC/DC Maintenance
Modern maintenance technicians may encounter:
AC Motor
VFD
DC Control Circuit
Battery Backup
Power Supply
Automation Equipment
Using an instrument that supports both AC and DC current measurements can reduce the need to change meters between different troubleshooting tasks.
Together with True RMS, VFD voltage, Inrush Current, High/Low-Z, frequency and other electrical measurement functions, DC current capability helps position the TA813B+ as a versatile industrial maintenance clamp meter.
Important Safety Considerations
Electrical measurements can involve hazardous voltage and current.
Only appropriately trained personnel should perform measurements on energized electrical systems.
Before using the instrument, verify:
Measurement category
Maximum voltage
Maximum current
Condition of the instrument
Test lead condition
Circuit characteristics
Applicable safety procedures
Always follow the TASI operating instructions and relevant electrical safety practices.
TASI TA813B+ AC/DC Clamp Meter Supplier Malaysia
Looking for the TASI TA813B+ True RMS AC/DC Digital Clamp Meter for battery, DC power supply, automation, factory maintenance or renewable energy applications?
Contact:
MTM Precision Sdn Bhd
Showroom & Service Centre
No 29-1 & 2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Supporting customers throughout Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.
26 Sep 2026