How to Measure DC Current with TASI TA813B+ Clamp Meter Malaysia

How to Measure DC Current with TASI TA813B+ Clamp Meter Malaysia

 

Measuring DC current does not always require disconnecting a circuit and inserting a conventional multimeter in series.

 

With a suitable AC/DC clamp meter such as the TASI TA813B+, technicians can measure DC current by clamping around the appropriate conductor.

 

This makes the TA813B+ particularly useful for technicians working with battery systems, DC power supplies, industrial control systems, automation equipment and renewable energy applications.

 

Why Is DC Current Measurement Useful?

 

Many people associate clamp meters mainly with AC electrical systems.

 

However, modern industrial and electrical installations can contain both AC and DC circuits.

 

Examples include:

 

Battery systems

 

DC power supplies

 

Industrial control systems

 

Automation equipment

 

Backup power systems

 

Renewable energy equipment

 

DC motors

 

Control panels

 

Automotive and machinery electrical systems

 

For technicians who regularly encounter both types of circuits, an AC/DC current clamp meter can provide greater measurement flexibility.

 

TA813B+ vs TA813A+ for DC Current

 

One important difference within the TASI TA813 Series is DC current measurement.

 

The TA813B+ supports DC current measurement, while the TA813A+ is intended for applications where this additional capability is not required.

 

The TA813B+ also provides DC Zero Adjustment, which is particularly relevant before performing DC clamp-current measurements.

 

For technicians working only with conventional AC systems, TA813A+ may cover many routine tasks.

 

For technicians who encounter:

 

AC Systems + DC Systems

 

the TA813B+ provides the broader measurement capability.

 

How Does a Clamp Meter Measure DC Current?

 

A clamp meter detects the magnetic field associated with current flowing through a conductor.

 

For current measurement, the clamp must be positioned around the appropriate single conductor.

 

For example:

 

DC Source (+) → Load → DC Source (-)

 

The clamp is placed around one conductor carrying the current.

 

If both positive and negative conductors are enclosed together, their magnetic fields can oppose each other and affect the measurement.

 

This is one of the most important points when using a clamp meter.

 

Step 1: Identify the Circuit

 

Before measuring, determine:

 

Is the circuit AC or DC?

 

What current level is expected?

 

Which conductor should be measured?

 

Is the expected value within the meter's measurement range?

 

Is the measurement safe to perform?

 

Do not start by simply clamping onto any available cable.

 

Understanding the circuit comes first.

 

Step 2: Select DC Current Measurement

 

Set the TASI TA813B+ to the appropriate DC current measurement mode.

 

Confirm the meter is configured correctly before placing the clamp around the conductor.

 

Step 3: Perform DC Zero Adjustment

 

DC clamp-current measurements can be affected by residual magnetic fields and sensor offset.

 

The TA813B+ provides DC Zero Adjustment to compensate for this before measurement.

 

With the clamp closed and positioned appropriately away from the conductor being measured, perform the zero adjustment according to the manufacturer's operating procedure.

 

This establishes a better reference point for the measurement.

 

Step 4: Clamp One Conductor

 

Open the clamp jaw and place it around the appropriate single conductor.

 

Avoid clamping both outgoing and return conductors together.

 

Keep the conductor positioned appropriately within the clamp according to the instrument instructions.

 

Step 5: Read the DC Current

 

Once the reading stabilizes, record the measured current.

 

The value can then be compared with:

 

Equipment specifications

 

Expected load

 

Previous readings

 

Similar equipment

 

Normal operating conditions

 

A current reading is most useful when there is something meaningful to compare it against.

 

Example: DC Power Supply Troubleshooting

 

Industrial control panels commonly use DC power supplies.

 

A simplified system may look like:

 

AC Supply → DC Power Supply → 24V DC Control System → PLC / Sensors / Relays

 

Suppose a machine experiences intermittent control problems.

 

A technician may need to investigate:

 

AC input

 

DC output voltage

 

DC load current

 

Wiring

 

Power supply condition

 

Connected equipment

 

DC current measurement provides another useful data point when evaluating the system.

 

Example: Battery System

 

Consider a battery supplying a DC load:

 

Battery → Protection → DC Load

 

The TA813B+ can be used to check current flowing through an accessible individual conductor, provided the application is within the instrument's specifications.

 

Possible applications include checking:

 

Load current

 

Current changes when equipment starts

 

Differences between operating conditions

 

Unexpected current consumption

 

Current measurement should always be interpreted together with voltage, battery condition and the design of the system.

 

TA813B+ for Solar and Renewable Energy

 

Renewable energy systems can contain both DC and AC sections.

 

A simplified solar system may contain:

 

PV / DC Source

 

↓

 

DC Circuit

 

↓

 

Inverter

 

↓

 

AC Circuit

 

↓

 

Electrical Load

 

This is one reason an AC/DC clamp meter can be useful for technicians working around renewable-energy equipment.

 

The same instrument can support current measurements on different parts of a system, subject to the meter's specified ratings and the equipment manufacturer's procedures.

 

TA813B+ for Industrial Automation

 

Automation equipment frequently combines conventional AC power with DC control circuits.

 

For example:

 

AC Power

 

↓

 

Power Supply

 

↓

 

24V DC

 

↓

 

PLC + Sensors + Relays + Control Devices

 

A technician who only has an AC current clamp meter cannot perform the same type of clamp-current measurement on the DC side.

 

The TA813B+ therefore provides additional flexibility for industrial maintenance technicians working across both power and control systems.

 

Why DC Zero Matters

 

DC current measurement differs from routine AC clamp measurement because the sensor can retain or detect an offset even when no current-carrying conductor is inside the jaw.

 

If the meter shows a small reading before the actual measurement, that offset can influence the final result.

 

This is why DC Zero Adjustment is an important companion feature to DC current measurement.

 

A simple concept is:

 

Close Clamp → Zero → Clamp Conductor → Measure

 

Always follow the manufacturer's instructions for the actual measurement procedure.

 

Common Mistake: Clamping the Whole Cable

 

A common mistake is to clamp around a cable containing both the positive and negative current paths.

 

For example:

 

+ Conductor → Load

 

- Conductor ← Load

 

If both are inside the clamp simultaneously, the opposing magnetic fields can cancel substantially.

 

This may result in a very low or misleading reading.

 

For normal current measurement, isolate and clamp the appropriate single conductor.

 

Common Mistake: Forgetting DC Zero

 

Another mistake is immediately taking a DC current reading without checking the meter's zero condition.

 

If an offset is present, it can affect the measurement.

 

This becomes especially important when the actual current being measured is relatively small compared with the meter's total measurement range.

 

DC Current Direction

 

DC current has direction.

 

Depending on clamp orientation and current flow, the instrument may indicate current polarity or direction through the displayed result.

 

If the reading appears with the opposite polarity from expected, check:

 

Clamp orientation

 

Current direction

 

Circuit polarity

 

Do not automatically assume the circuit itself has a fault.

 

DC Current vs DC Voltage

 

These measurements answer different questions.

 

DC Voltage

 

Shows the electrical potential difference between two points.

 

DC Current

 

Shows the current flowing through the circuit conductor.

 

A system can show apparently normal voltage while behaving differently under load.

 

For troubleshooting, technicians may therefore need to examine both:

 

Voltage + Current

 

rather than relying on only one measurement.

 

Building a DC Maintenance Baseline

 

For important equipment, technicians can record normal operating measurements.

 

For example:

 

EquipmentDC VoltageDC CurrentConditionControl Panel ARecordRecordNormalDC Power Supply BRecordRecordNormalBattery System CRecordRecordNormalMachine Control DRecordRecordNormal

 

When a problem occurs later, the new measurement can be compared against the previous baseline.

 

This is generally more useful than trying to interpret an isolated reading without historical information.

 

Why TA813B+ Is Useful for Mixed AC/DC Maintenance

 

Modern maintenance technicians may encounter:

 

AC Motor

 

VFD

 

DC Control Circuit

 

Battery Backup

 

Power Supply

 

Automation Equipment

 

Using an instrument that supports both AC and DC current measurements can reduce the need to change meters between different troubleshooting tasks.

 

Together with True RMS, VFD voltage, Inrush Current, High/Low-Z, frequency and other electrical measurement functions, DC current capability helps position the TA813B+ as a versatile industrial maintenance clamp meter.

 

Important Safety Considerations

 

Electrical measurements can involve hazardous voltage and current.

 

Only appropriately trained personnel should perform measurements on energized electrical systems.

 

Before using the instrument, verify:

 

Measurement category

 

Maximum voltage

 

Maximum current

 

Condition of the instrument

 

Test lead condition

 

Circuit characteristics

 

Applicable safety procedures

 

Always follow the TASI operating instructions and relevant electrical safety practices.

 

TASI TA813B+ AC/DC Clamp Meter Supplier Malaysia

 

Looking for the TASI TA813B+ True RMS AC/DC Digital Clamp Meter for battery, DC power supply, automation, factory maintenance or renewable energy applications?

 

Contact:

 

MTM Precision Sdn Bhd

 

Showroom & Service Centre

No 29-1 & 2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Tel: 03-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com

Website: www.mtmpre.com.my

 

Supporting customers throughout Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.


 

26 Sep 2026