UNI-T UT377C Drywall vs Masonry Mode How to Select the Correct Setting Malaysia

The UNI-T UT377C Pinless Moisture Meter provides separate Drywall and Masonry modes because different building materials respond differently to its induction sensor. Selecting the wrong mode can produce readings that are difficult to compare. Users should first identify the surface material and then keep the same setting throughout the inspection. What Is Drywall Mode? Drywall mode is intended for lightweight gypsum-based boards commonly used for: Internal partitions Office walls Ceiling boards Hotel-room partitions Decorative wall systems Lightweight renovation work Drywall is usually thinner and less dense than brick, concrete or cement plaster. The UT377C displays a relative value from 0 to 99.9 in Drywall mode. This value helps users compare different areas of the same material. It is not an absolute moisture-content percentage. What Is Masonry Mode? Masonry mode is designed for denser building materials such as: Brick walls Concrete surfaces Cement plaster Block walls Rendered walls Screed and similar mineral materials The UT377C also displays a relative value from 0 to 99.9 in Masonry mode. Because masonry construction can contain multiple layers, readings may be affected by plaster thickness, reinforcement, pipes and materials behind the visible surface. Drywall and Masonry Mode Comparison Inspection itemDrywall ModeMasonry ModeTypical materialGypsum boardBrick, concrete and plasterMaterial densityGenerally lowerGenerally higherDisplayed range099.9099.9Reading typeRelative valueRelative valueBest useLightweight partitions and ceilingsSolid walls and mineral surfacesMain limitationHidden studs and wiringReinforcement and mixed wall layers The numerical readings from the two modes should not be compared directly. How to Identify Drywall Drywall often has the following characteristics: Hollow sound when tapped Visible board joints in unfinished areas Lightweight internal partition construction Metal or timber studs behind the board Uniform and smooth surface Common use in offices, hotels and renovation projects If building drawings or renovation records are available, use them to confirm the wall construction. How to Identify Masonry Masonry walls may consist of: Brick with cement plaster Concrete blocks Reinforced concrete Cement render Solid partition blocks External walls exposed to weather These surfaces normally feel more solid when tapped. However, a masonry wall may still contain hollow sections, concealed pipes or different finishing layers. Correct Inspection Procedure Follow this process for more consistent readings: Identify the wall material. Select Drywall or Masonry mode. Find an area believed to be dry. Take several reference readings. Scan the suspected damp section. Keep the sensor flat against the surface. Record locations showing consistently higher values. Repeat the test using the same mode. Do not change modes halfway through the inspection and compare the numbers as if they came from the same scale. Example: Drywall Below an Air Conditioner An office partition below an air-conditioning unit shows peeling paint. Select Drywall mode and take reference readings away from the damaged section. Then scan below and beside the unit. Higher relative readings may indicate moisture caused by: Condensation A blocked drain pipe A loose drainage connection Damaged pipe insulation Previous leakage that has not fully dried The meter cannot determine which cause is responsible. Further inspection is required. Example: Masonry Wall Near a Bathroom A bedroom wall shared with a bathroom develops a damp stain. Select Masonry mode and compare the affected area with another section of the same wall. Scan from the floor upward and extend the measurement beyond the visible stain. A consistent pattern of higher readings may suggest moisture associated with plumbing, waterproofing or trapped water inside the wall. Why Does the Reading Change Suddenly? A sudden change does not always mean that moisture has increased. Possible causes include: Metal wall studs Pipes and electrical wiring Reinforcement bars Screws and fasteners Changes in plaster thickness Different construction materials Adhesive behind tiles Uneven sensor contact Measure around the location from several directions. A broader high-reading pattern is generally more useful than one isolated point. Can UT377C Measure Through Tiles? The meter may respond to conditions behind certain tile surfaces, but the reading can be influenced by: Tile material Tile thickness Adhesive layers Waterproofing membranes Gaps behind the tile Metal pipes Construction depth Results obtained over tiles should be treated as comparative screening information. Where possible, compare several tiled areas with similar construction. Important Reading Limitation Drywall and Masonry modes provide relative values only. Do not report a reading of 65 as “65% moisture.” Instead, record it as a relative reading and compare it with the selected reference area. For example: Reference wall: relative reading 18 Suspected area: relative reading 62 Observation: suspected area produces a significantly higher reading under the same test conditions This reporting method is more technically accurate. Choosing the Correct Mode Use Drywall mode for gypsum-board partitions and lightweight ceiling boards. Use Masonry mode for brick, concrete, plaster and other mineral-based surfaces. If the material cannot be identified, confirm the construction before relying on the results. Contact MTM Precision for the UNI-T UT377C or assistance selecting a suitable moisture meter for drywall, masonry and property-inspection applications in Malaysia. MTM Precision Sdn Bhd Showroom & Service Centre: No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia Tel: 03-8080 7172 WhatsApp: +6016-660 7346 Email: mtmpre@yahoo.com Website: www.mtmpre.com.my

30 Sep 2026