Solar Irradiance Testing During Cloudy and Hazy Weather with UNI-T UT381PV Malaysia

Solar Irradiance Testing During Cloudy and Hazy Weather with UNI-T UT381PV Malaysia Content Cloud cover and haze can reduce the amount of solar energy reaching photovoltaic panels. During these conditions, low solar output may be caused by the available sunlight rather than a defective panel or inverter. The UNI-T UT381PV Solar Irradiance Meter helps solar contractors and facility teams measure the actual irradiance present at the time of inspection. Why Weather Conditions Affect Solar Output Solar panels generate electricity from the solar energy reaching their surface. Available irradiance may change because of: Thick cloud cover Passing clouds Haze Rain High atmospheric moisture Smoke or airborne particles Morning and late-afternoon conditions Shadows from nearby structures When irradiance falls, solar panel output normally falls as well. Electrical readings should therefore be evaluated together with an irradiance measurement. Measure the Actual Irradiance The UT381PV measures solar irradiance from 0 to 1400 W/m². Place the instrument so that its sensor is exposed to the same sunlight as the panel. The sensor should be positioned in the same plane as the solar panel whenever possible. Avoid: Shading the sensor with your body Holding the meter at a different angle Measuring under a roof overhang Comparing different locations without recording the conditions Taking electrical and irradiance readings too far apart in time During cloudy weather, irradiance can change quickly. Record the irradiance and electrical output as close together as possible. Testing Under Passing Clouds Passing clouds can cause rapid increases and decreases in solar irradiance. For a useful inspection: Position the UT381PV beside the panel. Select a short data-recording interval. Start logging the irradiance. Record the PV output simultaneously. Note when clouds pass over the array. Compare the irradiance changes with the output changes. If electrical output follows the irradiance trend, the fluctuation may be weather-related. If output remains abnormally low after irradiance recovers, further system inspection may be required. Solar Testing During Haze Haze can reduce the solar energy reaching a PV system even when the sky still appears bright. A technician should not estimate irradiance based only on visual observation. Use the UT381PV to record the actual W/m² value at the site. During hazy conditions, record: Solar irradiance Ambient temperature Panel surface temperature PV voltage PV current or power Time of measurement General visibility Visible panel contamination These records provide context when explaining lower-than-usual generation to the system owner. Haze and Dirty Panels Are Different Problems Haze affects the sunlight passing through the atmosphere. Dirt affects the amount of sunlight passing through the panel surface. Both conditions may occur at the same time. Inspect the panels for: Dust Ash Bird droppings Leaves Construction residue Oil or industrial contamination To evaluate cleaning results, compare readings before and after cleaning under similar irradiance conditions. Do not assume that an increase in output is caused by cleaning if the sunlight became stronger during the second test. Check the Panel Temperature Cloudy or hazy weather does not always mean that panel temperature is low. The UT381PV measures temperature from −40°C to 120°C and includes a suction-cup probe for panel-surface measurement. Record panel temperature because: High temperature may reduce panel voltage Different roof areas may have different ventilation Dark surfaces may retain heat Irradiance may increase rapidly after a cloud passes Temperature may remain high even when sunlight temporarily decreases Irradiance and temperature should be considered together when interpreting PV output. Use Data Logging for Changing Conditions The UT381PV stores up to 12,800 measurement sets, with selectable recording intervals from one second to 60 minutes. Shorter intervals are useful for: Passing-cloud investigations Rapid irradiance changes Intermittent output complaints Short troubleshooting sessions Longer intervals may be useful for: Monitoring general weather trends Comparing morning and afternoon conditions Recording a longer haze period Tracking panel temperature Bluetooth connection to the UNI-T iENV App allows the recorded measurements to be reviewed more conveniently. When to Delay Performance Comparison A detailed comparison between panels or strings may be unreliable when weather conditions are changing rapidly. Consider delaying the comparison when: Clouds are moving quickly Different sections of the array receive different sunlight Rain repeatedly interrupts the inspection Irradiance changes substantially between measurements The panel surface is wet Safe rooftop access is affected by weather Measurements may still be recorded for troubleshooting, but their limitations should be stated in the report. When Additional Testing Is Needed If irradiance returns to a suitable level but the PV output remains abnormally low, inspect for: Partial shading Excessive panel temperature Incorrect inclination Wrong azimuth direction Loose connectors Damaged cables Panel mismatch Inverter faults Defective solar modules Additional electrical, insulation, thermal or I-V curve testing may be required. For assistance using the UNI-T UT381PV for solar irradiance measurement during cloudy and hazy conditions in Malaysia, contact MTM Precision. MTM Precision Sdn Bhd Showroom & Service Centre: No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia Tel: 03-8080 7172 WhatsApp: +6016-660 7346 Email: mtmpre@yahoo.com Website: www.mtmpre.com.my

30 Sep 2026