UNI-T UT381PV Solar Irradiance Measurement Errors and Solutions Malaysia

UNI-T UT381PV Solar Irradiance Measurement Errors and Solutions Malaysia Content An incorrect solar irradiance reading can lead technicians to misinterpret photovoltaic system performance. The problem may be caused by sensor positioning, changing weather, shading, temperature-probe contact or compass interference rather than a fault in the instrument. The UNI-T UT381PV Solar Irradiance Meter measures irradiance, temperature, inclination and azimuth. Each function requires the correct measurement method. Irradiance Reading Is Lower Than Expected A low irradiance reading may be caused by: Cloud cover or haze The sensor being partially shaded Incorrect sensor angle Dirt on the sensing surface Measurement under a roof overhang Early-morning or late-afternoon conditions The technician standing too close to the sensor What to Check Clean the sensor carefully and position the UT381PV in the same plane as the solar panel. Move away from anything that may cast a shadow. Repeat the reading while observing whether clouds or haze are affecting the available sunlight. Do not judge irradiance based only on how bright the sky appears. Irradiance Reading Changes Rapidly Solar irradiance can change quickly when clouds move across the site. Rapidly changing readings may therefore be normal under unstable weather conditions. What to Check Use the UT381PV data-logging function with a shorter recording interval. Compare the irradiance trend with the PV system’s electrical output. If both values change together, the variation may be weather-related. For panel-to-panel comparison, wait for more stable conditions or complete the measurements within a very short period. Similar Panels Show Different Irradiance Panels within the same installation may not receive identical sunlight. Possible causes include: Partial shading Different panel angles Different facing directions Uneven dirt accumulation Different sensor placement Measurements taken at different times What to Check Measure each panel using the same sensor position and orientation. Record the time, inclination and azimuth for every test. Inspect for shadows from panel rows, roof structures, trees, antennas or nearby buildings. Panel Temperature Appears Incorrect An unstable or unrealistic panel-temperature reading may be caused by poor probe contact. Possible causes include: Loose suction cup Dirt between the probe and panel Probe positioned over an uneven surface Insufficient time for the reading to stabilise Probe exposed to direct airflow Damaged probe or cable What to Check Clean the contact area and attach the suction-cup probe securely. Allow sufficient time for the temperature reading to stabilise. For comparison testing, attach the probe at approximately the same position on each panel. Remember that a contact probe measures only the temperature at its contact point. It does not provide a full thermal image of the module. Inclination Reading Is Inconsistent An inconsistent inclination reading may occur when the instrument is not sitting flat against the panel. What to Check Ensure that: The measurement surface is clean The instrument is aligned with the panel plane Mounting hardware is not affecting its position The panel is stable The reading has stopped changing The measurement is repeated at the same position Compare several panels if installation inconsistency is suspected. Azimuth Reading Is Unstable The UT381PV uses a compass-based function to determine azimuth from 0° to 360°. Nearby magnetic or metal objects may affect the result. Common sources of interference include: Steel roof structures Transformers Motors Magnets Heavy electrical cables Large metal equipment Vehicles What to Check Perform the compass-calibration procedure and move away from possible interference where practical. Allow the reading to stabilise and repeat it from another position. Compare the result with the installation drawing or a known site direction. Bluetooth Connection Is Unstable The UT381PV supports Bluetooth connection to the UNI-T iENV App. Connection problems may be caused by: Bluetooth being disabled Incorrect App version Excessive distance Walls or metal structures Electrical interference Another device already connected Low battery level What to Check Move the mobile device closer to the instrument. Confirm that Bluetooth is enabled and that the correct instrument has been selected in the App. Restart the instrument and application if necessary. Although the specified transmission distance may reach 100 metres under suitable open conditions, the actual range may be shorter at a working site. Data Is Not Recording as Expected The UT381PV stores up to 12,800 data sets with a selectable interval from one second to 60 minutes. Unexpected data gaps may be caused by: Incorrect recording interval Logging not started correctly Full storage capacity Low batteries Instrument switched off Bluetooth or App interruption What to Check Confirm the storage interval before starting the test. Check the available memory and battery condition. For important inspections, verify that the first few readings have been stored before leaving the instrument to continue logging. Results Do Not Match PV Output Solar irradiance is only one factor affecting photovoltaic output. A system may still produce low power because of: High panel temperature Partial shading Dirty panels Incorrect tilt or direction Loose connectors Damaged wiring Panel mismatch Inverter problems Defective modules Measure irradiance and panel temperature together. If environmental and installation conditions are acceptable, continue with suitable electrical or I-V curve testing. When the Instrument Requires Inspection Stop using the UT381PV and arrange further checking if: The display does not operate normally Readings remain unrealistic under stable conditions The temperature probe is damaged The sensor housing is cracked Water has entered the instrument The meter has suffered a severe impact Battery replacement does not restore operation Repeated measurements remain inconsistent after correct setup Do not open or modify the instrument unless the work is performed by authorised technical personnel. For assistance with the UNI-T UT381PV, send MTM Precision a clear photo of the instrument, display and accessories together with a description of the measurement problem. MTM Precision Sdn Bhd Showroom & Service Centre: No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia Tel: 03-8080 7172 WhatsApp: +6016-660 7346 Email: mtmpre@yahoo.com Website: www.mtmpre.com.my

30 Sep 2026