Solar Panel Cleaning Performance Test with UNI-T UT381PV Malaysia

Solar Panel Cleaning Performance Test with UNI-T UT381PV Malaysia Content Cleaning solar panels may improve output when dust, bird droppings, industrial residue or other contamination blocks sunlight from reaching the solar cells. However, comparing power readings before and after cleaning can be misleading if the solar irradiance or panel temperature changed between the two tests. The UNI-T UT381PV Solar Irradiance Meter helps technicians record the environmental conditions required for a more meaningful cleaning-performance comparison. Why Visual Inspection Is Not Enough A panel may look dusty without suffering a major output reduction. Another panel may appear relatively clean but contain localised contamination that creates shading. Common contaminants include: Dust and sand Bird droppings Leaves Pollen Construction residue Industrial particles Smoke or ash deposits Water marks Organic growth The effect depends on the amount, location and distribution of the contamination. Record the Conditions Before Cleaning Before cleaning the panel, record: Solar irradiance Ambient temperature Panel surface temperature PV voltage PV current or power Time of measurement Weather condition Visible contamination Shading condition The UT381PV measures solar irradiance from 0 to 1400 W/m² and temperature from −40°C to 120°C. Position the irradiance sensor in the same plane as the solar panel. Attach the supplied suction-cup temperature probe securely and allow the reading to stabilise. Photograph the Panel Condition Take clear photographs before cleaning. The photographs should show: The complete panel Close-up views of heavy contamination Any bird droppings or leaves Shaded areas Panel identification The surrounding roof or site condition Photographs support the maintenance report and help explain the condition before cleaning. Clean the Panel Safely Follow the solar installation’s approved cleaning and safety procedure. Important precautions may include: Isolating equipment when required Following rooftop fall-protection rules Avoiding work during unsafe weather Using suitable cleaning materials Avoiding abrasive tools Avoiding sudden thermal shock Protecting cables and connectors Preventing uncontrolled water entry Do not stand or place heavy equipment on the solar panels. Allow Conditions to Stabilise After cleaning, allow excess water to drain and the panel condition to stabilise. A wet panel may temporarily behave differently from a dry panel. Evaporative cooling may also reduce its surface temperature. Do not take the second reading immediately if: Water remains on the panel Clouds have moved across the site The panel temperature is changing rapidly Shadows have shifted The sensor position has changed The before-and-after conditions should be as similar as reasonably possible. Repeat the Measurements After cleaning, repeat the same measurements: Solar irradiance Ambient temperature Panel surface temperature PV voltage PV current or power Weather condition Measurement time Use the same instrument position and electrical test points. If possible, complete the before-and-after tests within a short period to reduce the influence of the sun’s movement and changing weather. Normalise the Result for Irradiance Suppose the panel produces more power after cleaning. The improvement may be partly caused by stronger sunlight during the second test. A simple field comparison can be made using: Relative output = Measured power ÷ Solar irradiance Example: Before cleaning: 280 W output at 800 W/m² After cleaning: 330 W output at 900 W/m² Before cleaning: 280 ÷ 800 = 0.350 After cleaning: 330 ÷ 900 = 0.367 The raw power increased by 50 W, but the irradiance-adjusted improvement is smaller. Panel temperature and other conditions must still be considered. This simplified comparison is useful for field evaluation but does not replace formal PV performance analysis. Consider the Panel Temperature A newly cleaned wet panel may be cooler than it was before cleaning. Lower temperature may temporarily improve voltage and output. Always record the panel surface temperature with the UT381PV. A more reliable comparison requires: Similar irradiance Similar panel temperature Identical electrical test points No new shading Stable weather The same panel condition, except for cleanliness If these conditions differ substantially, state the limitations in the report. Use Data Logging During Cleaning Tests The UT381PV stores up to 12,800 measurement sets with recording intervals from one second to 60 minutes. Data logging can show: Changes in irradiance during the work Panel cooling after washing Recovery of panel temperature Passing-cloud effects Output changes under stabilising conditions Bluetooth connection to the UNI-T iENV App makes it easier to review the measurement trend. When Cleaning Does Not Restore Output If output remains low after cleaning under suitable irradiance, investigate other possible causes: Partial shading Incorrect panel inclination Wrong azimuth direction Loose MC4 connectors Damaged cables Panel mismatch Failed bypass diode Inverter fault Defective solar module Insulation problem Additional electrical, thermal or I-V curve testing may be required. Recommended Test Record A solar panel cleaning report should include: Site and panel identification Before-and-after photographs Cleaning method Irradiance readings Ambient temperatures Panel temperatures Electrical readings Measurement times Weather observations Safety precautions Result and recommended action For assistance using the UNI-T UT381PV to evaluate solar panel cleaning performance in Malaysia, contact MTM Precision. MTM Precision Sdn Bhd Showroom & Service Centre: No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia Tel: 03-8080 7172 WhatsApp: +6016-660 7346 Email: mtmpre@yahoo.com Website: www.mtmpre.com.my

30 Sep 2026