RIKEN Precision Flat Level Frequently Asked Questions for CNC Machines Malaysia

RIKEN Precision Flat Level Frequently Asked Questions for CNC Machines Malaysia

 

Introduction

 

Choosing and using a precision flat level for CNC machines often raises technical questions.

 

Machine installation contractors, maintenance engineers, CNC technicians and quality control personnel may need to understand precision level sensitivity, instrument dimensions, calibration requirements and correct measurement procedures.

 

The RIKEN KEISOKUKI RFL-1502 and RFL-2002 Precision Flat Levels are Japanese instruments intended for machine assembly, installation and centering applications.

 

Both models feature 0.02 mm/m sensitivity, making them relevant to suitable precision machinery leveling applications.

 

MTM Precision Sdn Bhd supplies these RIKEN precision flat levels in Malaysia.

 

This comprehensive FAQ answers common questions about RIKEN RFL-1502, RFL-2002, CNC machine leveling, measurement accuracy, calibration, maintenance and troubleshooting.

 

1. What Is a Precision Flat Level?

 

A precision flat level is an instrument used to measure small angular inclination differences relative to a horizontal reference.

 

It is commonly used in precision machinery applications where sensitive inclination measurements are required.

 

Typical applications include:

 

CNC Machine Leveling

 

Precision Lathe Installation

 

CNC Milling Machine Setup

 

Machine Tool Maintenance

 

Industrial Equipment Assembly

 

Machine Relocation

 

Precision Machinery Inspection

 

A precision flat level differs from a general-purpose spirit level in its intended application and instrument specifications.

 

The correct instrument should be selected according to the machine manufacturer's requirements.

 

2. What Is the RIKEN RFL-1502 Precision Flat Level?

 

The RIKEN RFL-1502 is a Japanese precision flat level intended for precision machinery applications.

 

RIKEN RFL-1502 Specifications

 

SpecificationDetailsManufacturerRIKEN KEISOKUKIModelRFL-1502Country of OriginJapanInstrument TypePrecision Flat LevelNominal Length150 mmSensitivity0.02 mm/mNet Weight1.8 kgIntended ApplicationMachine Assembly, Installation and Centering

 

The 150 mm body may be useful where the designated measuring surface is relatively small.

 

However, instrument suitability must be confirmed against the actual measurement requirements.

 

3. What Is the RIKEN RFL-2002 Precision Flat Level?

 

The RIKEN RFL-2002 is another Japanese precision flat level intended for precision machinery applications.

 

RIKEN RFL-2002 Specifications

 

SpecificationDetailsManufacturerRIKEN KEISOKUKIModelRFL-2002Country of OriginJapanInstrument TypePrecision Flat LevelNominal Length200 mmSensitivity0.02 mm/mNet Weight2.3 kgIntended ApplicationMachine Assembly, Installation and Centering

 

The 200 mm body may be preferred where a longer suitable measuring surface is available.

 

The RFL-2002 is not automatically more accurate than the RFL-1502.

 

4. What Is the Difference Between RIKEN RFL-1502 and RFL-2002?

 

The main differences are nominal length and weight.

 

SpecificationRFL-1502RFL-2002Length150 mm200 mmSensitivity0.02 mm/m0.02 mm/mNet Weight1.8 kg2.3 kgCountry of OriginJapanJapanIntended ApplicationPrecision MachineryPrecision Machinery

 

Choose RFL-1502 When:

 

A shorter measuring body is suitable for the designated reference surface.

 

Choose RFL-2002 When:

 

A longer measuring body is preferred and sufficient measuring space is available.

 

Both models provide the same specified sensitivity.

 

The correct choice depends on the machine's measuring surface and inspection procedure.

 

5. What Does 0.02 mm/m Sensitivity Mean?

 

0.02 mm/m sensitivity represents an inclination equivalent to a height difference of 0.02 mm over a horizontal distance of one metre.

 

Equivalent Inclination Examples

 

Horizontal DistanceEquivalent Height Difference100 mm0.002 mm150 mm0.003 mm200 mm0.004 mm500 mm0.010 mm1,000 mm0.020 mm

 

The relationship is:

 

Height Difference (mm) = Inclination (mm/m) × Distance (m)

 

For example:

 

0.02 mm/m × 0.2 m = 0.004 mm

 

This illustrates the small inclination involved.

 

It does not mean that the instrument has guaranteed accuracy of 0.004 mm over 200 mm.

 

6. Is 0.02 mm/m the Same as Measurement Accuracy?

 

No.

 

Sensitivity and accuracy are different measurement characteristics.

 

Sensitivity

 

Sensitivity describes how an instrument responds to a change in inclination.

 

Accuracy

 

Accuracy concerns the closeness of a measured result to the reference value.

 

Measurement Uncertainty

 

Measurement uncertainty describes the uncertainty associated with a measurement result.

 

A precision level may have high sensitivity while still requiring calibration or verification to establish its measurement characteristics.

 

Do not interpret 0.02 mm/m sensitivity as a guaranteed accuracy specification.

 

7. Can RIKEN Precision Flat Levels Be Used for CNC Machine Installation?

 

Yes, when their specifications meet the machine manufacturer's requirements.

 

A precision flat level may be used to measure inclination at designated machine reference surfaces.

 

Typical applications include:

 

CNC lathe installation

 

CNC milling machine installation

 

Vertical machining center installation

 

Precision machinery assembly

 

Machine relocation

 

However, actual measuring positions and acceptable tolerances must follow the machine manufacturer's instructions.

 

A precision level alone does not complete every machine installation or geometry inspection requirement.

 

8. Can a Precision Flat Level Be Used for CNC Lathe Leveling?

 

A precision flat level may be suitable for CNC lathe leveling when it meets the manufacturer's measurement requirements.

 

Some lathe designs require careful support adjustment and bed twist inspection.

 

A technician may take inclination measurements at specified positions.

 

The results can assist with evaluating the machine's leveling condition.

 

However, the correct procedure depends on the lathe design.

 

Do not assume that every CNC lathe uses the same leveling method or tolerance.

 

9. Can a Precision Flat Level Be Used for CNC Milling Machines?

 

Yes, when the instrument meets the machine manufacturer's requirements.

 

A precision flat level may support inclination measurements during CNC milling machine installation and inspection.

 

However, machine geometry may also involve:

 

Axis straightness

 

Axis squareness

 

Spindle alignment

 

Positioning accuracy

 

Repeatability

 

These characteristics may require additional measuring instruments.

 

Machine leveling is only one aspect of machine tool inspection.

 

10. Can RIKEN Precision Levels Be Used for Vertical Machining Centers?

 

A RIKEN RFL-1502 or RFL-2002 may be suitable for specified leveling measurements on a Vertical Machining Center (VMC).

 

Before use, confirm:

 

Required Sensitivity

 

Does the manufacturer's procedure permit 0.02 mm/m sensitivity?

 

Reference Surface Dimensions

 

Can the measuring surface accommodate the instrument?

 

Measuring Positions

 

Are the correct reference positions identified?

 

Calibration Requirements

 

Does the inspection require documented calibration?

 

Additional Geometry Checks

 

Are other measuring instruments required?

 

A suitable precision level can support the leveling stage but does not replace complete VMC inspection.

 

11. What Is the Difference Between a Precision Flat Level and a Standard Spirit Level?

 

A general-purpose spirit level is commonly used for construction and general installation work.

 

A precision flat level is intended for more sensitive inclination measurements.

 

Comparison

 

FeatureGeneral Spirit LevelRIKEN Precision Flat LevelTypical ApplicationGeneral LevelingPrecision MachinerySensitivityDepends on Model0.02 mm/mCNC Machine LevelingDepends on SpecificationSuitable When Requirements MatchInstrument LengthVaries150 mm or 200 mm

 

A standard spirit level should not be assumed suitable for precision CNC machine leveling without checking its specifications.

 

12. Can a Precision Flat Level Detect Machine Bed Twist?

 

A precision level may support certain machine bed twist inspection procedures.

 

For some machine designs, measurements at different reference positions can help evaluate changes in inclination.

 

However, the interpretation depends on the manufacturer's procedure.

 

A single reading cannot establish whether a machine bed is free from twist.

 

Bed twist inspection requires suitable measuring positions, consistent measurement technique and appropriate acceptance criteria.

 

13. Why Does My Precision Level Show Different Readings?

 

Different readings may result from several factors.

 

Surface Contamination

 

Metal chips, dust or oil residue may affect instrument seating.

 

Instrument Position

 

Small changes in placement may affect the contact conditions.

 

Temperature Changes

 

Thermal effects may influence the machine or measurement conditions.

 

Vibration

 

Nearby machinery may cause unstable indications.

 

Machine Movement

 

The actual inclination of the machine may change.

 

Instrument Condition

 

Damage or calibration-related problems may affect measurement performance.

 

Investigate the measurement conditions before assuming that the instrument is defective.

 

14. Why Is the Bubble Indication Unstable?

 

An unstable indication may be associated with:

 

Vibration

 

Poor instrument seating

 

Unsuitable measurement conditions

 

Temperature changes

 

Instrument condition

 

Recommended Troubleshooting

 

First, confirm that the instrument is positioned on the correct reference surface.

 

Next, check the surface for contamination.

 

Then, reduce excessive vibration where possible.

 

Allow the indication to stabilize before recording the reading.

 

If the problem continues, appropriate instrument verification may be necessary.

 

Do not adjust machine supports based on unstable measurements.

 

15. Can Temperature Affect Precision Level Measurements?

 

Yes.

 

Temperature differences can influence precision measurement conditions.

 

For example, a precision level moved from an air-conditioned room to a warmer factory may initially be at a different temperature from the machine.

 

For critical measurements:

 

Follow the inspection procedure's environmental requirements.

 

Allow suitable thermal stabilization.

 

Avoid unnecessary exposure to heat sources.

 

Record relevant temperature conditions when required.

 

Temperature stability supports consistent precision leveling measurements.

 

16. Can Vibration Affect Precision Level Readings?

 

Yes.

 

Excessive vibration may make the indication unstable.

 

Possible sources include:

 

CNC machines

 

Industrial motors

 

Compressors

 

Heavy production equipment

 

Material handling activities

 

Where practical, measurements should be performed under suitable stable conditions.

 

A precision flat level measures inclination.

 

It is not a substitute for a vibration meter or vibration analyzer.

 

17. How Should I Clean a RIKEN Precision Flat Level?

 

Precision flat levels should be cleaned carefully.

 

General Recommendations

 

Inspect the Measuring Surface

 

Check for visible contamination.

 

Remove Loose Debris Carefully

 

Avoid rubbing hard particles across precision surfaces.

 

Use Suitable Cleaning Materials

 

Follow the manufacturer's approved cleaning method.

 

Keep the Instrument Dry

 

Avoid leaving moisture or cleaning residue on relevant surfaces.

 

What Should Be Avoided?

 

Do not use abrasive paper, grinding materials or metal scrapers on precision measuring surfaces.

 

Avoid unapproved solvents and unauthorized disassembly.

 

Always follow the manufacturer's specific cleaning instructions where available.

 

18. How Should I Store a Precision Flat Level?

 

Proper storage helps protect precision measuring instruments.

 

Recommended Practices

 

Use a suitable protective case.

 

Store the instrument in a dry environment.

 

Protect it from accidental impact.

 

Avoid unnecessary temperature extremes.

 

Keep it away from loose heavy tools.

 

Follow the manufacturer's recommended storage arrangement.

 

The correct storage orientation should follow the manufacturer's instructions.

 

Good storage practice helps reduce avoidable damage and contamination.

 

19. What Should I Do If My Precision Level Is Dropped?

 

An accidental drop may affect the instrument's condition.

 

Recommended Actions

 

Stop Critical Measurement Work

 

Do not assume the instrument remains suitable.

 

Inspect for Visible Damage

 

Check the body and measuring surfaces.

 

Avoid Unauthorized Adjustment

 

Do not attempt internal repairs without appropriate instructions.

 

Arrange Verification

 

Have the instrument inspected or calibrated where necessary.

 

Confirm Suitability Before Reuse

 

Ensure that the instrument meets the intended measurement requirements.

 

A precision level may require verification even if no obvious external damage is visible.

 

20. How Often Should a Precision Flat Level Be Calibrated?

 

There is no universal calibration interval suitable for every precision level.

 

The appropriate interval depends on:

 

Frequency of use

 

Handling conditions

 

Measurement criticality

 

Previous calibration results

 

Environmental exposure

 

Quality system requirements

 

Manufacturer recommendations

 

Calibration May Be Required:

 

At a Scheduled Interval

 

According to the organization's calibration program.

 

After Significant Impact

 

When instrument performance may have changed.

 

After Repair or Adjustment

 

When relevant measurement characteristics require verification.

 

Before Critical Work

 

When the applicable procedure requires confirmation of calibration status.

 

Calibration frequency should be based on measurement risk and applicable requirements.

 

21. Is a Calibration Certificate Required for CNC Machine Leveling?

 

Calibration documentation requirements depend on the intended application.

 

Some organizations require measuring instruments to have documented calibration status.

 

Others may have different verification requirements.

 

Important Questions

 

Does the customer require a calibration certificate?

 

Is accredited calibration required?

 

Is the instrument within its calibration interval?

 

Is the measurement uncertainty suitable?

 

Does the calibration scope cover the relevant measurement?

 

If accredited calibration is required, confirm the calibration provider's accreditation scope.

 

A manufacturer's sensitivity specification does not replace calibration documentation when such documentation is required.

 

22. Can a Precision Flat Level Calibrate a Complete CNC Machine?

 

No.

 

A precision flat level measures inclination.

 

A complete CNC machine geometry or performance assessment may require additional measurements.

 

These may include:

 

Straightness

 

Squareness

 

Spindle runout

 

Positioning accuracy

 

Axis repeatability

 

Contouring performance

 

Different instruments are required for different measurement tasks.

 

Examples

 

InstrumentTypical ApplicationPrecision Flat LevelInclinationDial IndicatorDisplacement and runout comparisonPrecision StraightedgeStraightness-related checksPrecision SquareSquareness-related referenceLaser InterferometerSpecified positioning measurementsBallbar SystemCertain contouring performance tests

 

A precision level is one instrument within a broader machine inspection system.

 

23. Can a Precision Flat Level Be Used After Machine Relocation?

 

Yes, when it meets the machine manufacturer's leveling requirements.

 

Machine relocation may change:

 

Foundation conditions

 

Support arrangements

 

Machine inclination

 

Certain geometric characteristics

 

After relocation, the machine may require reinstallation and verification.

 

A RIKEN Precision Flat Level may support suitable leveling measurements.

 

However, additional geometry and operational checks may be necessary.

 

Correct leveling does not automatically establish complete machine accuracy after relocation.

 

24. Which RIKEN Precision Flat Level Should I Buy?

 

The choice depends on the measuring surface and intended application.

 

Choose RIKEN RFL-1502 When:

 

A 150 mm body is suitable for the approved reference surface and inspection procedure.

 

Choose RIKEN RFL-2002 When:

 

A 200 mm body is preferred and sufficient measuring space is available.

 

Both Models Offer:

 

Japanese Manufacture

 

0.02 mm/m Sensitivity

 

Precision Machinery Applications

 

Important Buying Questions

 

What machine will be inspected?

 

Identify the machine manufacturer and model.

 

What sensitivity is required?

 

Check the machine manual.

 

What measuring surface is available?

 

Confirm the dimensions.

 

Is calibration documentation required?

 

Clarify before purchasing.

 

Do not choose solely by instrument length or price.

 

25. Can Factories Share One Precision Level Between Departments?

 

Yes, when the instrument meets the requirements of the intended applications.

 

A factory may share a precision level between:

 

Maintenance Department

 

QA/QC Department

 

Metrology Team

 

Machine Installation Team

 

However, shared instruments should be controlled appropriately.

 

Recommended Management Practices

 

Instrument Identification

 

Assign a unique instrument identification number where required.

 

Storage Responsibility

 

Identify the department responsible for the instrument.

 

Calibration Control

 

Maintain applicable calibration records.

 

Damage Reporting

 

Establish a procedure for reporting suspected damage.

 

Measurement Documentation

 

Record the instrument used for important inspections.

 

Clear instrument control supports consistent measurement practices.

 

26. Can a Precision Level Be Used to Inspect a Used CNC Machine?

 

Yes, for suitable leveling-related inspection activities.

 

However, a precision level cannot establish the complete condition of a second-hand CNC machine.

 

Used machine inspection may also require evaluation of:

 

Machine geometry

 

Spindle condition

 

Axis movement

 

Positioning accuracy

 

Maintenance history

 

Control system operation

 

Test machining performance

 

A precision flat level should be used as part of an appropriate inspection program.

 

A machine that appears level is not automatically in good mechanical condition.

 

27. Where Are RIKEN Precision Flat Levels Used in Malaysia?

 

The RIKEN Precision Flat Level Series is relevant to precision machinery applications across Malaysia.

 

Selangor and Kuala Lumpur

 

CNC workshops, precision engineering factories and machine tool service companies may require sensitive leveling instruments.

 

Johor

 

Manufacturing facilities and machinery installation contractors may use precision levels during equipment setup.

 

Penang

 

Precision engineering and electronics manufacturing companies may require precision leveling instruments.

 

Melaka and Negeri Sembilan

 

Industrial equipment maintenance companies may use precision levels for suitable machine inspection applications.

 

Perak and Kedah

 

Machine tool workshops and industrial engineering companies may require precision leveling equipment.

 

MTM Precision Sdn Bhd supports product enquiries throughout Malaysia, including Pahang, Kelantan, Terengganu, Perlis, Sabah and Sarawak.

 

28. Where Can I Buy RIKEN RFL-1502 and RFL-2002 in Malaysia?

 

MTM Precision Sdn Bhd supplies Japanese RIKEN precision flat levels for industrial machinery applications.

 

RIKEN RFL-1502 Precision Flat Level

 

Length: 150 mm

 

Sensitivity: 0.02 mm/m

 

Net Weight: 1.8 kg

 

Origin: Japan

 

RIKEN RFL-2002 Precision Flat Level

 

Length: 200 mm

 

Sensitivity: 0.02 mm/m

 

Net Weight: 2.3 kg

 

Origin: Japan

 

Typical Applications

 

CNC Machine Installation

 

Precision Lathe Leveling

 

CNC Milling Machine Setup

 

Machine Tool Maintenance

 

Machine Relocation

 

Precision Machinery Inspection

 

Industrial Equipment Assembly

 

Contact MTM Precision for current pricing and stock availability.

 

29. Contact MTM Precision Sdn Bhd

 

MTM Precision Sdn Bhd

 

Showroom & Service Centre

 

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Telephone: 03-8080 7172

 

WhatsApp: +6016-660 7346

 

Email: mtmpre@yahoo.com

 

Website: www.mtmpre.com.my

 

For RIKEN RFL-1502 and RFL-2002 Precision Flat Level Malaysia enquiries, contact our team through WhatsApp.

 

Please send us your machine model, required sensitivity, measuring surface dimensions or application details.

 

Our team can assist with product selection and quotation requests.

 

If calibration documentation is required, please mention this when enquiring so that available options can be checked.

 

Conclusion

 

Understanding precision flat level sensitivity, instrument dimensions, measurement procedures and calibration requirements helps technicians select and use suitable instruments for CNC machine applications.

 

The RIKEN RFL-1502 and RFL-2002 Precision Flat Levels both feature 0.02 mm/m sensitivity.

 

The RFL-1502 has a 150 mm body, while the RFL-2002 has a 200 mm body.

 

Both instruments are intended for precision machinery applications and are supplied by MTM Precision Sdn Bhd in Malaysia.

 

For customers searching for RIKEN Precision Flat Level Malaysia, contact MTM Precision for product information, quotations and assistance selecting a suitable instrument.


 

11 Oct 2026