DITRON 635 Series Digital Height Gauges | 200mm to 1000mm Height Measurement & Scribing Malaysia

DITRON 635 Series Digital Height Gauges


The DITRON 635 series is designed for height measurement and scribing, with measuring ranges from 0–200mm to 0–1000mm.


The catalogue lists digital readout, zero-setting, millimetre/inch conversion, data hold, preset and tolerance-setting functions. A fine-adjustment device supports controlled positioning, while a carbide-tipped scriber provides a contact for marking suitable workpieces.


For machining workshops and inspection departments in Malaysia, select the model according to workpiece height, required accuracy and reference surface arrangement.


PRODUCT HIGHLIGHTS


• Height measurement and scribing.

• Six measuring ranges from 200mm to 1000mm.

• Digital readout.

• Power ON/OFF.

• Zero-setting at any position.

• Millimetre/inch conversion at any position.

• Data hold.

• Preset function.

• Tolerance-setting function.

• Fine-adjustment device.

• Carbide-tipped scriber.


MODELS AND SPECIFICATIONS


DITRON 635-200

Measuring range: 0–200mm

Catalogue-stated accuracy: ±0.04mm


DITRON 635-300

Measuring range: 0–300mm

Catalogue-stated accuracy: ±0.04mm


DITRON 635-500

Measuring range: 0–500mm

Catalogue-stated accuracy: ±0.05mm


DITRON 635-600

Measuring range: 0–600mm

Catalogue-stated accuracy: ±0.05mm


DITRON 635-800

Measuring range: 0–800mm

Catalogue-stated accuracy: ±0.06mm


DITRON 635-1000

Measuring range: 0–1000mm

Catalogue-stated accuracy: ±0.07mm


The supplied catalogue page does not explicitly specify display resolution. Confirm this separately when preparing a purchasing or inspection specification.


CHOOSING THE MEASURING RANGE


200mm and 300mm Models

For workpieces and measuring locations within the selected capacity. Both list ±0.04mm accuracy.


500mm and 600mm Models

For taller components requiring additional travel. Both list ±0.05mm accuracy.


800mm Model

Provides a 0–800mm range with ±0.06mm stated accuracy.


1000mm Model

The largest listed model provides a 0–1000mm range with ±0.07mm stated accuracy.


Allow for the workpiece, fixture and selected contact arrangement when assessing usable access. A taller gauge does not automatically provide higher accuracy.


HEIGHT MEASUREMENT FROM A REFERENCE SURFACE


A height gauge measures a contact position relative to an established reference.


Use a suitable surface plate or reference surface with adequate flatness for the task. The gauge base and workpiece must sit securely, without chips or residue underneath.


The reference arrangement matters as much as the measuring range. A dirty base, unstable component or incorrect contact position can affect the result.


SCRIBING WITH A CARBIDE-TIPPED CONTACT


The catalogue specifies a carbide-tipped scriber for marking workpieces.


Scribing can be used to establish layout lines at a selected height on suitable materials. Position and secure the measuring assembly according to the operating instructions before marking.


A scribed line is a layout reference. Confirm final component dimensions using the appropriate inspection procedure.


FINE ADJUSTMENT


The fine-adjustment device helps users approach the required height or measuring surface gradually.


It does not establish constant-force measurement. Use light, consistent contact force and avoid loading the scriber or measuring assembly excessively.


ZERO, PRESET AND DATA HOLD


Zero-Setting

Allows a reference to be established at a selected position for comparative measurements.


Preset

Allows a reading to be assigned at a selected position, following the manufacturer’s instructions.


Data Hold

Allows a displayed reading to be retained according to the instrument’s operating procedure.


Check the active reference and selected unit before recording measurements.


These functions do not by themselves establish a coded absolute encoder, position retention after power loss or computer connectivity.


TOLERANCE SETTING


The catalogue lists a tolerance-setting function.


Confirm how upper and lower limits are entered and how the instrument indicates the result. The supplied page does not explain the indication method or specify an audible alarm.


Tolerance settings must match the drawing and inspection procedure. They do not replace checking instrument suitability and measurement conditions.


ACCESSORIES AND CONFIGURATION


The catalogue illustrates scribers, mounting components and extension accessories for different model sizes.


Confirm:

• Which accessories are included.

• Compatibility with the selected measuring range.

• Available contact and scriber configurations.

• Whether extensions require a different reference-setting procedure.

• Whether the stated accuracy applies to the intended setup.


Do not assume every accessory shown is supplied with every model.


APPLICATIONS IN MALAYSIA


The DITRON 635 series can be considered for:


• Machined component height checks.

• Step height comparison.

• Layout and scribing.

• Fixture and setup checks.

• Incoming component inspection.

• Toolroom and fabrication measurements.


For workshops and factories in Selangor, Kuala Lumpur, Johor and Penang, select according to component height, tolerance, contact access and the available surface plate.


The height gauge does not by itself establish complete geometric characteristics such as flatness or perpendicularity. Those assessments require an appropriate method and setup.


ACCURACY AND MEASUREMENT CONDITIONS


Catalogue-stated accuracy ranges from ±0.04mm to ±0.07mm across the listed models.


Measurement results also depend on:

• Reference surface condition.

• Cleanliness beneath the base and workpiece.

• Contact alignment and force.

• Workpiece stability.

• Temperature differences.

• Accessory configuration.

• Instrument condition.


Display resolution and accuracy are separate specifications. Do not infer resolution from the product photograph.


BASIC MEASURING PROCEDURE


1. Clean the reference surface, gauge base and workpiece.

2. Confirm that the gauge and component sit securely.

3. Fit and secure the appropriate contact or scriber.

4. Establish the reference according to the operating instructions.

5. Confirm the selected unit and any preset value.

6. Move the contact towards the measuring location.

7. Use fine adjustment for controlled final positioning.

8. Apply light, consistent contact force.

9. Read or hold the result as required.

10. Repeat the measurement to assess consistency.


Recheck the reference after changing accessories or if readings become inconsistent.


CARE AND STORAGE


• Keep the base contact surface clean and protected.

• Avoid impact to the column, slider and scriber.

• Do not force the slider or measuring contact.

• Handle the carbide-tipped scriber carefully.

• Avoid measuring hot components.

• Follow the supplied power, cleaning and maintenance instructions.

• Store with the measuring assembly protected.

• Check performance against suitable reference standards according to your quality procedure.


The supplied page does not explicitly specify battery type, rechargeable operation, Bluetooth capability or an IP protection rating.


FREQUENTLY ASKED QUESTIONS


What does the DITRON 635 measure?

The catalogue identifies height measurement and scribing as its primary applications.


What measuring ranges are available?

The page lists 200mm, 300mm, 500mm, 600mm, 800mm and 1000mm models.


What is the accuracy of the 635-600?

The catalogue lists ±0.05mm.


What is the display resolution?

It is not explicitly specified on the supplied page. Confirm before ordering if required.


Does it have fine adjustment?

Yes. A fine-adjustment device is listed.


Does it include a carbide-tipped scriber?

A carbide-tipped scriber is listed. Confirm the supplied accessory configuration for the selected model.


Can it switch between millimetres and inches?

Yes. Millimetre/inch conversion at any position is listed.


Does tolerance setting include an alarm?

The page does not specify an audible alarm or explain the indication method.


Can it send readings to a computer?

Computer connectivity and data output are not specified on this page. Data hold should not be confused with data transmission.


Is a calibration certificate included?

The supplied page does not confirm inclusion of an individual calibration certificate. Specify documentation requirements when requesting a quotation.


SEO META DESCRIPTION


Explore DITRON 635 digital height gauges in Malaysia, with 200mm to 1000mm ranges, fine adjustment, preset, tolerance setting and carbide-tipped scribing.


ENQUIRE ABOUT DITRON DIGITAL HEIGHT GAUGES


Contact MTM Precision with your required measuring range, workpiece height, tolerance and quantity. Include details of the reference surface and any required scriber or accessory configuration.


Please specify any resolution, tolerance indication or calibration documentation requirements. Availability, final configuration and supplied accessories are subject to confirmation.


MTM Precision Sdn Bhd

Showroom & Service Centre: No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia

Tel: 03-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com

Website: www.mtmpre.com.my

25 Oct 2026