DITRON 705A Vertical Digital Scale | 150mm to 300mm Machine Travel Measurement Malaysia
Selecting a Vertical Digital Scale for Machine Slides and Positioning Fixtures
The DITRON 705A Vertical Digital Scale provides a digital indication of linear movement on a compatible machine slide or positioning assembly. Its vertical display arrangement, mounting brackets and connection holes support installation where operators need to read vertical travel directly.
The series includes three measuring ranges: 0–150mm, 0–200mm and 0–300mm. Functions listed in the catalogue include zero-setting at any position, data hold, reading preset and millimetre/inch conversion.
For workshops and equipment users in Malaysia, model selection should consider the required travel, installation dimensions, mounting arrangement and measurement accuracy.
KEY FEATURES
Vertical Display Arrangement
The reading head is arranged for a vertical installation. Position it where the operator can read the display and reach the controls throughout the intended movement.
Mounting Brackets and Connection Holes
The catalogue identifies brackets at both ends and connection holes on the moving assembly. These provide attachment points for a suitable installation.
The actual bracket arrangement must match the fixed and moving parts of the machine without restricting travel or loading the scale sideways.
Zero-Setting at Any Position
The operator can establish a reference at a selected position. This is useful for checking movement from a setup datum or comparing positions during an adjustment.
Data Hold
The hold function retains the displayed measurement for reading or recording. It does not mechanically lock the machine slide.
Reading Preset
The preset function allows a selected reading to be assigned at a position. This can support a measurement setup that uses a known reference value.
Millimetre/Inch Conversion
The catalogue lists unit conversion at any position, allowing operators to work with metric or imperial dimensions.
DITRON 705A MODEL SPECIFICATIONS
All dimensions below are in millimetres.
Model: 705A-150
Measuring range: 0–150mm
Accuracy: ±0.03mm
L1: 294mm
L2: 270mm
A: 20mm
B: 4mm
C: 40mm
D: 6mm
Model: 705A-200
Measuring range: 0–200mm
Accuracy: ±0.03mm
L1: 344mm
L2: 320mm
A: 20mm
B: 4mm
C: 40mm
D: 6mm
Model: 705A-300
Measuring range: 0–300mm
Accuracy: ±0.04mm
L1: 444mm
L2: 420mm
A: 20mm
B: 4mm
C: 40mm
D: 6mm
L1, L2 and A–D refer to the dimension labels in the manufacturer’s drawing. Confirm their relationship to the mounting points before preparing installation brackets.
The supplied catalogue page does not state the display resolution.
HOW TO CHOOSE THE CORRECT MODEL
Choose by Required Travel
The 705A-150 covers movement up to 150mm, the 705A-200 covers up to 200mm, and the 705A-300 covers up to 300mm.
Check the full intended operating stroke, including setup and adjustment positions. Ensure that machine movement cannot drive the scale beyond its measuring travel.
Check Installation Length
Measuring range and physical installation length are different.
For example, the 705A-150 has a 150mm measuring range, while the drawing lists L1 as 294mm and L2 as 270mm. A space that accommodates 150mm of movement may still be too short for the complete assembly.
Check Accuracy Against the Application
The 150mm and 200mm models have a listed accuracy of ±0.03mm. The 300mm model has a listed accuracy of ±0.04mm.
Installed measurement performance also depends on alignment, bracket rigidity, machine condition and the reference-setting method. Consider the complete setup when assessing suitability for a drawing tolerance.
Check Access and Clearance
Allow room for the reading head, controls, mounting hardware and surrounding machine components. Confirm that the display remains accessible and that no part of the assembly collides during travel.
POTENTIAL APPLICATIONS
Vertical Machine Slide Positioning
The scale may be installed on a compatible vertical slide to indicate movement during manual adjustment. Suitability depends on the machine geometry and available mounting points.
Adjustable Workshop Fixtures
The zero and preset functions can support fixtures where positions are set relative to a chosen datum.
Equipment Setup and Maintenance
A local travel reading can help technicians document adjustment positions or compare movement during setup checks.
Production Positioning Assemblies
The scale may suit manually adjusted mechanisms that require a visible position reading. The mounting arrangement should be assessed for the specific equipment.
These applications are relevant to engineering and maintenance teams in Selangor, Penang, Johor and other industrial areas in Malaysia.
USING ZERO, PRESET AND HOLD
Zero-Setting
Use zero-setting when movement needs to be measured from a selected starting point. Establish the reference consistently before comparing readings.
Preset
Use preset when a known position should display a specified reference value. Check the entered value and units before continuing.
Data Hold
Use hold to retain a reading for recording. Release hold before monitoring further movement so that a retained value is not mistaken for a live position.
Zero-setting and preset functions do not, by themselves, establish that the instrument uses an absolute position encoder. The supplied page does not specify its encoder technology.
INSTALLATION AND INITIAL CHECKING
1. Identify the fixed and moving attachment points.
Determine how the scale and reading head will follow the required movement. Use the connection arrangement shown in the manufacturer’s instructions.
2. Align the scale with the travel direction.
Avoid twisting the assembly or forcing the reading head to follow a misaligned path.
3. Use rigid supports.
Flexible brackets or loose fasteners can change position independently of the machine and affect readings.
4. Check the complete movement.
Move the assembly slowly through its intended stroke. Look for interference, binding and movement at the mounting points.
5. Establish the reference.
Set the required zero or preset value using a suitable datum.
6. Verify readings at several positions.
Compare movement against an appropriate reference before relying on the installation for production decisions.
The digital scale should not be used as a machine stop, structural guide or support for a moving load.
VERTICAL DIGITAL SCALE OR HEIGHT GAUGE?
A vertical digital scale measures relative movement between its scale and reading head within an installed assembly.
A height gauge normally operates from a reference surface and uses a contact or scriber to measure or mark workpiece heights.
Select the instrument according to the task. For machine travel indication, assess the installed scale. For bench height measurement and scribing, assess a suitable height gauge.
INFORMATION TO CONFIRM BEFORE ORDERING
Provide the required travel, machine photographs, available mounting space and working environment.
Also confirm any requirements for display resolution, power supply, external data output or environmental protection. These details are not specified on the supplied 705A catalogue page.
Specifications from the horizontal 705B series should not be assumed to apply to the vertical 705A series.
FREQUENTLY ASKED QUESTIONS
What ranges are available?
The catalogue lists 0–150mm, 0–200mm and 0–300mm models.
What is the stated accuracy?
The 705A-150 and 705A-200 are listed at ±0.03mm. The 705A-300 is listed at ±0.04mm.
Does it have data hold?
Yes. Data hold is listed in the catalogue.
Can I set zero at a selected position?
Yes. The catalogue specifies zero-setting at any position.
Does it support preset readings?
Yes. A reading preset function is listed.
Can it display millimetres and inches?
Yes. Millimetre/inch conversion is listed.
What is the resolution?
The supplied page does not state the resolution. Confirm this specification when requesting a quotation.
Can it connect to an external DRO display?
The supplied page does not specify an external display interface. Confirm compatibility before purchase.
SEO META DESCRIPTION
Explore DITRON 705A vertical digital scales in Malaysia. Compare 150–300mm ranges, accuracy, mounting dimensions, zero, preset and data hold functions.
CONTACT MTM PRECISION
Contact MTM Precision with your required travel, machine photos and mounting dimensions for assistance selecting a DITRON 705A Vertical Digital Scale.
MTM Precision Sdn Bhd
Showroom & Service Centre: No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
25 Oct 2026