DITRON 705B Horizontal Digital Scale | 100mm to 300mm Linear Travel Measurement Malaysia

Choosing a Horizontal Digital Scale for Machine and Fixture Travel


The DITRON 705B Horizontal Digital Scale measures linear movement on machine workbenches, slides and positioning fixtures. It provides a local digital reading of travel, helping operators check movement when adjusting a machine axis or setting a fixture position.


The series includes four measuring ranges: 0–100mm, 0–150mm, 0–200mm and 0–300mm. All models have a listed resolution of 0.01mm / 0.0005in.


For workshops in Malaysia, choosing the correct model involves more than matching the measuring range. Installation space, mounting alignment, moving clearance and exposure to machining debris also affect suitability.


WHAT IS A HORIZONTAL DIGITAL SCALE?


A horizontal digital scale measures displacement along a straight path. Unlike a handheld caliper, it is intended to be mounted to an assembly.


The scale and reading head must move relative to each other as the machine table or fixture travels. The mounting arrangement should follow that movement without twisting the scale or placing side loads on the reading head.


The supplied DITRON catalogue identifies applications on milling machines, lathes, sliding table saws, woodworking equipment and fixture slides. Suitability depends on the individual machine and installation.


KEY FEATURES


Local Digital Display


The integrated display allows the operator to read linear movement directly at the installation point. This is useful for manual positioning and repeated setup checks.


Four Measuring Ranges


The 100mm, 150mm, 200mm and 300mm options cover different travel requirements. Select a range that accommodates the complete intended movement.


ABS Housing and Stainless Steel Scale


The catalogue specifies an ABS housing and a 4Cr13 stainless steel ruler. These material specifications do not establish an ingress protection rating.


Automatic Power Functions


The scale switches on when the reading head slides and switches off after five minutes of inactivity.


CR2032 Battery


The catalogue specifies one CR2032 3V button cell. Battery life is not stated on the supplied page.


DITRON 705B MODEL SPECIFICATIONS


Model: 705B-100

Measuring range: 0–100mm / 4in

Resolution: 0.01mm / 0.0005in

Accuracy: ±0.02mm


Model: 705B-150

Measuring range: 0–150mm / 6in

Resolution: 0.01mm / 0.0005in

Accuracy: ±0.02mm


Model: 705B-200

Measuring range: 0–200mm / 8in

Resolution: 0.01mm / 0.0005in

Accuracy: ±0.03mm


Model: 705B-300

Measuring range: 0–300mm / 12in

Resolution: 0.01mm / 0.0005in

Accuracy: ±0.04mm


The accuracy values above reproduce the metric specifications on the supplied catalogue page. The inch range descriptions are nominal catalogue size labels.


RESOLUTION IS DIFFERENT FROM ACCURACY


A resolution of 0.01mm describes the display increment. It does not mean the complete measurement is accurate to ±0.01mm.


For example, the 705B-300 displays in 0.01mm increments but has a listed accuracy of ±0.04mm.


Installed performance also depends on mounting rigidity, alignment, machine movement and the condition of the measuring assembly. Consider these factors when deciding whether the scale suits a particular positioning tolerance.


HOW TO SELECT THE CORRECT RANGE


Measure the Required Travel


Determine the full movement that the scale must follow. Include setup positions and normal operating travel, rather than considering only the most common adjustment.


Check the Installation Envelope


The measuring range is not the overall physical length. Allow space for the scale body, end brackets, reading head and its movement.


The supplied page includes dimensional drawings for each size. Confirm the relevant mounting dimensions against the actual machine before drilling holes or manufacturing brackets.


Check Display Visibility


Position the display where it can be read during normal operation. Avoid locations hidden behind guards, handles or the workpiece.


Check Moving Clearance


Verify clearance throughout the complete travel. The reading head and brackets must not collide with stops, guards, machine structures or other moving components.


Assess the Working Environment


The supplied page does not state an IP rating. For installations exposed to coolant, chips or heavy dust, assess the need for suitable shielding and confirm product suitability before ordering.


TYPICAL APPLICATIONS


Milling Machine Table Travel


A horizontal scale can provide a local indication of table movement during manual positioning. Alignment and secure mounting are essential.


Lathe Slide Positioning


The scale may be considered for a compatible slide arrangement where its range, orientation and mounting space suit the machine.


Woodworking Equipment Adjustments


A suitable installation can help indicate linear adjustments on woodworking equipment or sliding assemblies. Protect the measuring components from accumulated dust and impact.


Fixture and Jig Positioning


The scale can indicate movement on adjustable stops, inspection fixtures and workshop slides, helping operators return to a reference position.


These applications are relevant to machining, fabrication and maintenance workshops in Selangor, Penang, Johor and other industrial areas in Malaysia.


INSTALLATION PRINCIPLES


Keep the Scale Parallel to Travel


Misalignment can create measurement error or cause the reading head to bind. The scale should follow the intended measurement axis.


Use Rigid Mounting Points


Loose brackets or flexible supports can move independently of the machine, producing unstable or misleading readings.


Avoid Loading the Reading Head


The scale is a measuring device. It should not act as a structural guide, machine stop or support for a moving assembly.


Check the Full Stroke


Move the machine slowly through the intended travel after installation. Check for interference, binding and bracket movement.


Verify Against a Suitable Reference


Check readings at several positions using an appropriate reference method. This helps identify installation problems before the scale is used for production decisions.


Account for Machine Behaviour


The scale indicates movement at its mounting location. Backlash, tool deflection, workpiece movement and machine geometry can still affect the finished component.


WHAT THIS CATALOGUE PAGE DOES NOT CONFIRM


The supplied page does not specify external DRO compatibility, data output, wireless connectivity, an absolute encoder system or an IP protection rating.


If the application requires a remote display, automated data collection or operation in a wet machining environment, confirm those requirements separately.


Do not assume that automatic switch-on means the instrument uses an absolute position encoder.


CARE AND ROUTINE CHECKING


Keep the scale and reading head clean using a suitable non-abrasive method. Avoid forcing debris through the sliding assembly.


Periodically inspect the mounting screws, brackets and battery compartment. If readings become intermittent or unstable, check the battery, cleanliness, mounting security and alignment.


After replacing the battery, moving the brackets or servicing the machine, re-establish the reference and verify readings before returning to measurement work.


FREQUENTLY ASKED QUESTIONS


What does the DITRON 705B measure?


It measures linear displacement between the scale and reading head, typically on a machine table, slide or fixture.


Which ranges are available?


The catalogue lists 100mm, 150mm, 200mm and 300mm measuring ranges.


What is the resolution?


All four models have a listed resolution of 0.01mm / 0.0005in.


What battery does it use?


The catalogue specifies one CR2032 3V button cell.


Does it switch off automatically?


Yes. The catalogue states automatic switch-off after five minutes of inactivity and switch-on when sliding.


Can it connect to an external DRO display?


The supplied page does not confirm an external display interface. Connection requirements must be checked before purchase.


Is it coolant-proof?


No coolant protection rating is stated on the supplied page. Confirm suitability and the required protective arrangement for the intended installation.


What details should I provide when requesting a quotation?


Provide the required travel, machine type, available mounting space, working environment and photographs of the proposed installation area.


SEO META DESCRIPTION


Explore DITRON 705B horizontal digital scales in Malaysia. Compare 100–300mm ranges, 0.01mm resolution and mounting needs for machine slides and fixtures.


CONTACT MTM PRECISION


Contact MTM Precision with your machine photos, required travel and mounting dimensions for assistance selecting a DITRON 705B Horizontal Digital Scale.


MTM Precision Sdn Bhd

Showroom & Service Centre: No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia

Tel: 03-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com

Website: www.mtmpre.com.my

25 Oct 2026