Professional Fuzrr ES4000 Power Quality Analyzer (Malaysia)
Professional Fuzrr ES4000 Power Quality Analyzer (Malaysia)
Product Applications
-
Comprehensive power quality auditing and system fault troubleshooting for three-phase electrical power distribution grids
-
Harmonic pollution analysis and Total Harmonic Distortion (THD) monitoring up to the 50th harmonic order
-
Transformer load analysis, K-factor calculation, and energy efficiency profiling (W, VA, var, PF, DPF, cos phi, tan phi)
-
Motor inrush current startup capture (100-second record mode) and dynamic voltage/current transient monitoring
-
Long-term electrical power parameter trend logging and alarm monitoring for industrial plants, commercial buildings, and data centers
Key Features & Operational Advantages
-
Simultaneous 8-Channel Measurement: Measures 4 voltage channels (ABC three-phase and neutral to ground) and 4 current channels (ABC three-phase and neutral current) concurrently.
-
Real-Time Waveform & Phasor Display: Displays real-time 4-channel voltage and current waveforms,dynamic vector phasor diagrams, and harmonic ratio bar charts on a 5.6-inch color screen.
-
Harmonic & THD Analysis (0 to 50th Order): Measures harmonic components and total harmonic distortion (THD) up to the 50th order for each phase independently.
-
Transient Capture & Inrush Current Monitoring: Features transient capture capabilities (recording up to 150 transient groups) and a 100-second startup current record mode.
-
Extended Trend Logging & Alarm Management: Logs up to 20 power parameters simultaneously every 5 seconds for up to 300 days, storing up to 12,800 group alarm logs across 40 parameter types.
-
Versatile Current Sensor Options: Compatible with various current clamps (10mA to 10.0A tip clamp,0.10A to 100A round clamp, 1.0A to 1000A round clamp) and flexible Rogowski coils measuring up to 6000A.
Technical Specifications — Fuzrr ES4000
Core Measurement Parameters
-
Primary Functions: Real-time waveform display (4 channels voltage/current), True RMS voltage and current, peak current and voltage, min/max values over time, phasor diagram display, harmonic measurement up to 50th harmonic, Total Harmonic Distortion (THD) calculation, active/reactive/apparent power, phase total power, transformer K-factor, voltage flicker, three-phase unbalance calculation
-
Number of Channels: 4 voltage channels, 4 current channels
-
Line Voltage Range: 1.0V to 2000V
-
Phase Voltage Range: 1.0V to 1000V
-
Current Measurement Options:
-
008 tip small current clamp: 10mA to 10.0A (Jaw size: 8mm x 15mm, optional selection)
-
020 round-mouth current clamp: 0.10A to 100A (Jaw size: 20mm x 20mm, optional selection)
-
050 round-mouth current clamp: 1.0A to 1000A (Jaw size: 50mm x 50mm, optional selection)
-
Rogowski coil: 10A to 6000A
-
Optional transformer port input current: 1mA to 500mA
-
-
Power & Energy Parameters: W, VA, var, PF, DPF, cos phi, tan phi, Wh, varh, Vah
-
Harmonic Analysis: 0 to 50th harmonic order
-
Total Harmonic Distortion (THD): Supported, 0 to 50th order for each phase
Diagnostic Modes & Data Logging
-
Expert Mode: Supported
-
Transient Records: 150 record groups
-
Voltage Flicker: Supported
-
Startup Current Mode: Supported, 100 seconds recording window
-
Three-Phase Unbalance: Supported
-
Long-Term Trend Record: Up to 300 days (records 20 parameters simultaneously, sampling 1 point every 5 seconds)
-
Minimum / Maximum Value Recording: Supported over custom time periods
-
Alarm Logs: Configurable across 40 parameter types, supporting 12,800 group alarm log records
-
Peak Value & Phasor Display: Supported, with automatic phasor diagram positioning
-
Screenshot Capacity: Stores up to 60 screen captures
Hardware, Physical & Environmental Parameters
-
Power Supply: Rechargeable lithium battery pack 9.6V, with external charger
-
Display Screen: 5.6-inch color LCD screen (640 dots x 480 dots resolution, display field: 116mm x 88mm)
-
Instrument Dimensions: Length 277.2mm x Width 277.5mm x Height 153mm
-
Ingress Protection Rating: IP45
-
Production Compliance & Safety Standards: IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031,IEC61326, Pollution Grade 2
Why Choose MTM Precision in Malaysia?