Anchor Pull-Out Testing for Structural Steel Installation Malaysia
Anchor Pull-Out Testing for Structural Steel Installation Malaysia
Structural Steel Anchor Pull-Out Testing Malaysia
Structural steel installation often relies on anchors to connect steel components to concrete structures.
Depending on the project, these anchoring systems may be used for:
Steel brackets
Base plates
Support frames
Equipment structures
Retrofit steelwork
Secondary steel members
Handrails and barriers
M&E support structures
Building extension works
Where required by the project specification, consultant or structural engineer, selected installed anchors may need to undergo anchor pull-out or proof-load testing as part of construction QA/QC.
For suitable applications requiring up to 200kN measurement range, the Langry APT200 Anchor Pull-Out Tester provides a professional field-testing option.
Why Are Structural Steel Anchors Pull-Out Tested?
The performance of an anchoring system depends on more than the anchor product itself.
Actual installed performance can also be influenced by:
Concrete condition
Hole diameter
Hole depth
Hole cleaning
Embedment depth
Chemical adhesive installation
Mechanical anchor setting
Installation torque
Anchor spacing
Edge distance
Workmanship
Pull-out testing can provide verification of selected installed anchors according to the approved project procedure.
Common Structural Steel Anchor Applications
Anchor pull-out testing may be relevant to steel installations involving:
Steel Brackets
Post-installed anchors may be used to fix steel brackets to existing concrete.
Base Plates
Steel support frames and equipment structures may use anchored base plates.
Retrofit Steelwork
Existing buildings may require new structural or secondary steel components connected to old concrete.
Support Frames
Steel frames for services, equipment or strengthening may rely on post-installed anchors.
Machinery and Equipment Supports
Industrial steel structures may require anchor verification before equipment is installed.
Chemical Anchors for Structural Steel
Chemical anchors are often used where threaded rods or steel bars are bonded into drilled holes.
Important installation factors include:
Correct drilling
Correct hole diameter
Proper hole cleaning
Correct adhesive injection
Required embedment
Correct rod installation
Required curing time
Where specified, pull-out testing can be used to verify selected completed anchors.
Mechanical Anchors for Structural Steel
Mechanical or expansion anchors may also be used for structural steel fixings.
Their installed performance can depend on:
Hole size
Embedment
Correct setting
Installation torque where specified
Concrete condition
Edge distance
Anchor spacing
The testing method should be compatible with the approved anchor system.
What Is a Structural Steel Anchor Proof Test?
A proof test generally applies a predetermined tensile load to the installed anchor without intentionally loading it to ultimate failure.
The test may evaluate whether the anchor:
Reaches the specified proof load
Maintains the load where required
Shows acceptable movement
Shows no unacceptable visible failure
The exact acceptance criteria should come from the approved project documentation.
Proof Test Is Not the Same as Pulling to Failure
A site request may simply say:
“Do pull-out test.”
But the actual requirement may be:
“Proof load the selected structural anchor to the specified force.”
These are different test objectives.
Before testing begins, clarify:
Proof test or destructive test?
Required load?
Holding time?
Acceptance criteria?
Test quantity?
Who Determines the Required Test Load?
The test operator should not guess the load from the anchor diameter.
Depending on the project, the required force may come from:
Structural engineer
Consultant
Approved anchor design
Project specification
Approved method statement
Testing procedure
The pull-out tester only provides the force measurement range.
200kN Tester Does Not Mean 200kN Test Load
The Langry APT200 provides:
0–200kN measurement range
This does not mean every structural steel anchor should be tested to 200kN.
For example:
Project Required Proof Load: 85kN
Tester Capacity: 200kN
The test target remains 85kN, subject to the approved procedure.
How to Select the Correct Tester Capacity
Langry offers:
ModelMaximum RangeApproximate CapacityAPT100100kN10 TonAPT200200kN20 TonAPT300300kN30 Ton
Selection should be based on the maximum required test load.
When Might APT100 Be Enough?
APT100 may be considered where:
Required loads remain below 100kN
Higher loads are not expected
Site portability is important
The full test setup must still be reviewed.
When Might APT200 Be Better?
APT200 becomes relevant where:
Required loads may exceed 100kN
Maximum test load remains within 200kN
Different project types are expected
Greater flexibility is needed
This makes it a useful middle-capacity option for structural contractors and testing companies.
When Is APT300 Needed?
APT300 should be considered where required test loads can exceed 200kN.
Do not select it simply because it is the largest model.
Structural Steel Base Plate Anchor Testing
Base plates may use cast-in or post-installed anchoring systems depending on the project.
Where post-installed anchors are involved, selected anchors may require testing before the steelwork is accepted or loaded.
Before testing, confirm:
Anchor type
Anchor size
Required load
Exposed thread
Base plate geometry
Reaction setup
Access around the anchor
Base plate geometry can affect tester positioning.
Steel Bracket Anchor Testing
Steel brackets often create restricted access around the anchor.
Potential issues include:
Limited exposed thread
Bracket obstruction
Nearby bolts
Limited cylinder clearance
Difficult reaction setup
For these applications, a site photograph is highly useful before mobilisation.
Retrofit Structural Steel Testing
Retrofit work often involves connecting new steel components to existing concrete.
Potential applications include:
Building strengthening
Equipment upgrades
New steel supports
Structural modification
Additional platforms
Service structures
Existing concrete conditions can vary significantly, so inspection before testing is important.
Check the Existing Concrete Condition
Before testing, inspect for:
Cracking
Honeycombing
Surface deterioration
Previous drilling
Edge damage
Repairs
Weak local concrete
The surrounding substrate forms part of the anchoring system.
Check Exposed Thread Length
Structural steel installations frequently involve nuts, washers and steel plates.
These may leave very little accessible thread.
Before testing, confirm:
Thread size
Exposed thread length
Whether nuts can be removed
Whether the adapter can engage securely
This simple check can prevent a failed site visit.
Check the Reaction Setup
The hydraulic cylinder requires an appropriate reaction arrangement.
The operator should consider:
Steel plate geometry
Concrete surface
Anchor location
Nearby anchor positions
Edge distance
Available support area
The reaction setup should be appropriate to the approved test method.
Alignment Is Important
The applied tensile force should generally be as axial as practical.
Poor alignment can introduce:
Bending
Side load
Uneven force transfer
Test instability
This is particularly important where anchors are close to steel brackets or plates.
Chemical Anchor Curing Must Be Complete
If the structural steel connection uses chemical anchors, confirm the required curing conditions before testing.
Do not assume the anchor is ready simply because installation occurred the previous day.
Curing requirements depend on the approved chemical anchoring system and relevant conditions.
How Many Structural Steel Anchors Should Be Tested?
There is no universal percentage.
The required number should follow:
Project specification
Structural engineer requirement
Consultant requirement
Approved sampling plan
Approved method statement
Do not automatically assume 5%, 10% or another fixed value.
What Happens If One Anchor Fails?
A failed anchor should be documented and handled according to the approved project procedure.
Possible next steps may include:
Engineering review
Installation investigation
Additional testing
Corrective work
Replacement or redesign
The testing operator should not invent corrective action independently.
Typical Failure Behaviours
Possible observations include:
Anchor pull-out
Bond-related failure
Concrete breakout
Concrete cracking
Steel failure
Test connection failure
Record both the force and the observed behaviour.
What Should the Test Report Include?
A professional structural steel anchor test report may include:
Project name
Test location
Anchor ID
Anchor type
Anchor size
Steel bracket or base plate reference
Required load
Maximum applied load
Holding time
Movement where required
Observations
Pass/fail result
Equipment information
Calibration information where required
Photographs
Why Photographs Are Useful
Photographs can show:
Overall steel connection
Anchor location
Pull-out tester setup
Force reading
Anchor after testing
Any visible damage
This helps engineers interpret the result later.
Langry APT200 for Structural Anchor Testing
The Langry APT200 provides:
Measurement Range: 0–200kN
Approximate Capacity: 20 Ton
Key specifications include:
SpecificationLangry APT200Measurement Range0–200kNCylinder Centre Hole35mmCylinder Stroke70mmCommon AnchorageΦ6–Φ25Pull RodM24ConverterM6–M22Data Storage500 RecordsAccuracy ClassificationEN ISO 7500-1 Class 1
Suitability should be confirmed against the actual structural anchor configuration and required load.
Who May Need This Equipment?
Potential users include:
Structural steel contractors
Main contractors
Building contractors
Steel fabricators with site-installation teams
QA/QC departments
Engineering consultants
Inspection companies
Testing laboratories
Retrofit contractors
Common Structural Steel Testing Mistakes
No Approved Test Load
Never start with “pull until it looks strong.”
Wrong Adapter
Anchor thread and exposed length must be confirmed.
Poor Clearance
Base plates and brackets may obstruct the cylinder.
Testing Before Chemical Anchor Cure
Follow the approved curing requirement.
Poor Alignment
Avoid side loading and bending.
No Anchor ID
Every result should be traceable to the actual connection.
No Calibration Check
Confirm project documentation requirements before mobilisation.
Frequently Asked Questions
Why are structural steel anchors pull-out tested?
Where required, testing helps verify selected installed anchors as part of construction QA/QC.
Can chemical anchors used for steel brackets be tested?
Yes, suitable chemical anchoring systems can be pull-out tested according to the approved procedure.
Can mechanical anchors be tested?
Yes, suitable mechanical and expansion anchors can also be tested.
Is every structural anchor tested to failure?
No. Many project requirements may involve proof testing rather than deliberate destructive testing.
Who decides the required force?
The appropriate structural engineer, consultant or approved project documentation should define it.
Does M16 mean I need a 20-ton tester?
No. Anchor diameter does not directly determine tester capacity.
Can Langry APT200 be used for structural steel anchor testing?
It can be suitable where the required load and test configuration fall within its 200kN measurement range.
Where can I buy structural anchor testing equipment in Malaysia?
Contact MTM Precision Sdn. Bhd. for Langry APT-series anchor pull-out testing equipment, model selection and quotation in Malaysia.
Structural Steel Anchor Pull-Out Tester Supplier Malaysia
MTM Precision supplies professional construction and civil engineering testing equipment for structural contractors, QA/QC teams and testing companies throughout Malaysia.
For faster equipment selection, send:
Anchor Type + Anchor Size + Required Test Load + Steel Connection Photo
For example:
M16 Chemical Anchor + 120kN + Steel Bracket + Site Photo
This allows the most suitable Langry configuration to be reviewed before quotation.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
For Langry APT200 Structural Steel Anchor Pull-Out Tester Malaysia, current quotation, model selection and professional construction testing equipment enquiries, contact MTM Precision.
12 Aug 2026