Langry APT100 vs APT200 vs APT300 Which Anchor Pull-Out Tester Should You Buy for Your Project? Malaysia

Langry APT100 vs APT200 vs APT300 Which Anchor Pull-Out Tester Should You Buy for Your Project? Malaysia Langry Anchor Pull-Out Tester Selection Guide Malaysia Choosing between the Langry APT100, APT200 and APT300 should not be based only on price or tonnage. The correct model depends on the actual project requirement. Before buying, you should confirm: What anchor are you testing? What is the required test load? What is the maximum expected load? What anchor diameter is involved? What connection is required? Will testing be performed at height? What calibration or reporting requirements apply? Langry offers three main capacity classes: APT100 100kN / 10 Ton Class APT200 200kN / 20 Ton Class APT300 300kN / 30 Ton Class For many mixed construction applications, the APT200 provides a practical middle range, but it is not automatically the best model for every project. Quick Comparison APT100 vs APT200 vs APT300 ModelMaximum Measurement RangeApproximate CapacityGeneral UseAPT100100kN10 TonLower-load applicationsAPT200200kN20 TonMedium / mixed applicationsAPT300300kN30 TonHigher-load applications This table is only a starting point. The final selection should match the actual testing requirement. Step 1 Know the Required Test Load This is the most important factor. If your required load is: 70kN a 100kN tester may potentially be sufficient. If your required load is: 140kN a 100kN tester is not enough. If your required load is: 220kN a 200kN tester is not enough. Therefore: Required Test Load → Determines Minimum Capacity Step 2 Do Not Buy Based Only on Anchor Diameter Customers often ask: “I test M16. Which model should I buy?” M16 alone is not enough information. The same M16 anchor size can be used in different: Chemical anchor systems Mechanical anchor systems Embedment depths Concrete conditions Structural applications Proof-load requirements Always obtain the required test load. Step 3 Identify the Anchor Type The equipment may be used for suitable: Chemical anchors Mechanical anchors Expansion bolts Threaded rods Anchor rods Steel bars Faade anchors Structural steel anchors Different anchor types may require different connection arrangements. Step 4 Check the Thread Size The pull-out tester must connect securely to the anchor. For the Langry APT200 configuration, common pulling accessories include: M24 Pull Rod M6M22 Converters The actual connection should still be confirmed for each application. Step 5 Check Exposed Thread Length Even when the diameter is correct, the anchor may not have enough usable thread. Before buying or testing, confirm: Thread size Exposed length Whether nuts can be removed Whether brackets obstruct the connection Whether the adapter can engage properly Step 6 Check the Test Geometry A pull-out tester needs enough physical space around the anchor. Potential obstructions include: Steel brackets Base plates Faade profiles Nearby anchors Concrete edges Machinery structures For unusual configurations, send photographs and dimensions before equipment selection. APT100 When Should You Choose It? The Langry APT100 provides a maximum measurement range of: 0100kN approximately: 10-ton class capacity APT100 may be suitable when: Required loads remain below 100kN You mainly test lighter anchors Higher-load projects are unlikely Portability is important Your testing scope is relatively consistent If your projects clearly stay below 100kN, additional capacity may not be necessary. APT200 When Should You Choose It? The Langry APT200 provides: 0200kN approximately: 20-ton class capacity APT200 may be a strong choice when: Required loads may exceed 100kN Maximum expected loads remain within 200kN You work on different project types You test chemical and mechanical anchors You want more flexibility than APT100 This makes APT200 particularly suitable for many contractors, QA/QC teams and testing companies. APT300 When Should You Choose It? The Langry APT300 provides: 0300kN approximately: 30-ton class capacity APT300 should be cnsidered when: Required loads can exceed 200kN You regularly handle heavier anchoring systems APT200 would limit your project range Higher-capacity work is part of your normal service Do not choose APT300 simply because it is the largest model. APT100 vs APT200 Which Is Better? The answer depends on your required load. Choose APT100 if: Your work consistently stays below 100kN. Choose APT200 if: Your required loads can exceed 100kN but remain within 200kN. For companies serving multiple projects, APT200 may provide more flexibility. APT200 vs APT300 Which Is Better? Again, the required load determines the answer. Choose APT200 if: Your maximum required testing range stays within 200kN. Choose APT300 if: You genuinely need to test above 200kN. Extra capacity is useful only when your work requires it. Is Bigger Always Better? No. A higher-capacity tester may involve: More weight Larger equipment Higher cost More difficult handling Less convenient use at height The best tester is not necessarily the biggest. It is the tester that properly matches your normal and future work. Which Model for Chemical Anchor Testing? There is no single model that is correct for all chemical anchors. Selection depends on: Anchor diameter Required test load Chemical anchor system Embedment Base material Project requirement A practical guide: Below 100kN → APT100 may be sufficient 100200kN → APT200 may be suitable 200300kN → APT300 may be required Which Model for Faade Contractors? Faade contractors may work with: Chemical anchors Expansion anchors Bracket fixings Curtain wall anchors Because different projects can require different proof loads, the APT200 may provide a useful middle range. However, check actual project data before purchasing. Which Model for Structural Steel Contractors? Structural steel contractors may require anchor testing for: Base plates Steel brackets Retrofit steelwork Support structures The selected model should cover the maximum required test load. Which Model for Testing Laboratories? Testing companies should consider future service range, not only one project. They should review: Historical jobs Maximum est loads Typical anchor sizes Customer requirements Calibration requirements Portability For mixed medium-range work, APT200 may be a practical option. Which Model for QA/QC Teams? Internal QA/QC teams should choose according to the projects they normally manage. If the company performs only low-load anchor checks, APT100 may be sufficient. If projects vary significantly, APT200 may provide better flexibility. If high-load testing is common, APT300 should be evaluated. Which Model for M&E Contractors? M&E supports may involve: Pipe supports Cable trays HVAC structures Equipment frames Testing requirements vary greatly. Do not assume a specific capacity based only on anchor size. Proof Test or Failure Test? This question should be answered before buying. Proof Test A predetermined load is applied according to the approved procedure. Ultimate / Failure Test The anchor may be loaded toward a defined failure condition. Failure testing can require more available capacity than a routine proof test. Why Capacity Margin Can Matter Suppose your current maximum project requirement is: 95kN APT100 technically reaches 100kN. But if your company expects future projects above 100kN, APT200 may provide useful flexibility. Selection should consider both current and realistic future requirements. Do Not Use Tester Capacity as Test Load If you buy APT300, this does not mean: Every anchor should be tested to 300kN. If the approved test load is: 80kN then the required target remains 80kN. The model defines measurement capability. The project defines the test. Compare Langry APT Models Before Buying RequirementAPT100APT200APT300Up to 100kNYesYesYes100200kNNoYesYes200300kNNoNoYesLower weight priorityBetterModerateHigher-capacity systemMixed contractor workPossibleStrong optionPossibleHigher-load specialist testingLimitedLimited above 200kNBetter The final model should still match the actual test configuration. Langry APT200 Key Specifications The APT200 remains the middle model of the range. SpecificationLangry APT200Measurement Range0200kNApproximate Capacity20 TonCylinder Centre Hole35mmCylinder Stroke70mmCylinder WeightApprox. 13kgCommon AnchorageΦ6Φ25Pull RodM24ConverterM6M22Data Storage500 RecordsContinuous Working Time>200 HoursAccuracy ClassificationEN ISO 7500-1 Class 1 Five Questions Before You Buy Before asking: “How much?” answer these first: 1. What anchor type? Chemical, mechanical, expansion anchor or steel bar? 2. What anchor size? M12, M16, M20 or another size? span style="font-size:18px";>3. What is the required load? This is the most important capacity factor. 4. What is the application? Faade, structural steel, QA/QC, M&E or testing laboratory? 5. Can you send a photo? A photograph can reveal connection and clearance issues. Example 1 M12 Chemical Anchor, 50kN Required load: 50kN APT100 may potentially provide sufficient capacity. APT200 and APT300 also have enough measurement range, but the user should consider whether the additional size, capacity and cost are useful. Example 2 M16 Chemical Anchor, 135kN Required load: 135kN APT100 does not provide enough range. APT200 may be considered because the required load is within its 200kN range. Example 3 M20 Structural Anchor, 230kN Required load: 230kN APT200 is insufficient. APT300 should be evaluated. This is why the project load matters more than anchor diameter alone. Example 4 Faade Contractor with Mixed Projects Suppose a faade company normally sees projects between: 50kN and 160kN A 100kN tester would limit some projects. A 300kN tester may provide more capacity than normally required. In this situation, the APT200 can offer a practical middle range. Calibration Requirements Before purchasing equipment for professional testing, also check: Calibration certificate requirements Equipment traceability Serial number documentation Reporting requirements The equipment model is only one part of a complete professional testing system. Data Recording Requirements The Langry APT series supports up to: 500 measurement records This can be useful for: Large faade projects Construction QA/QC Testing laboratories Multi-point anchor testing However, digital readings should still be linked to the correct anchor ID and location. What Should You Send MTM Precision? For accurate model selection, send: Anchor Type Anchor Size Required Test Load Application Photo of Actual Installation For example: M16 Chemical Anchor + 135kN + Curtain Wall Bracket + Site Photo This is far more useful than simply asking: “Need 20-ton tester price.” Frequently Asked Questions Which Langry anchor pull-out tester should I buy? Choose according to the maximum required test load, anchor type, connection and site conditions. Is APT100 enough? Yes, if your required testing range remains within 100kN and the configuration is suitable. Whychoose APT200? APT200 provides a useful middle range for applications requiring more than 100kN but not more than 200kN. When should I buy APT300? Consider APT300 when your required loads can exceed 200kN. Is APT300 better than APT200? Not automatically. It provides more capacity, but the best model depends on your application. Can one APT200 test M12, M16 and M20 anchors? Potentially, for suitable configurations within the supported connection and 200kN measurement range. The actual application should be checked individually. Is 200kN approximately 20 tons? Yes. 200kN corresponds to approximately 20.4 metric tonnes-force. Should I choose by tonnage or kN? Use the project-required force in the specified engineering unit, normally kN, as the primary capacity reference. Where can I buy Langry APT100, APT200 or APT300 in Malaysia? Contact MTM Precision Sdn. Bhd. for Langry anchor pull-out testing equipment, model selection and current quotation in Malaysia. Langry Anchor Pull-Out Tester Supplier Malaysia MTM Precision supplies professional construction, civil engineering and testing equipment for customers throughout Malaysia. Whether you are a: Contractor Faade contractor Structural steel contractor QA/QC team Inspection company Testing laboratory we recommend selecting the pull-out tester according to actual project requirements rather than simply choosing the highest capacity. Send: Anchor Type + Anchor Size + Required Test Load + Application + Photo and we can help determine whether the Langry APT100, APT200 or APT300 is the more appropriate option. Contact MTM Precision MTM Precision Sdn. Bhd. Showroom & Service Centre No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia 🌐 Website: www.mtmpre.com.my 📧 Email: mtmpre@yahoo.com 📱 WhatsApp: +6016-660 7346 For Langry APT100, APT200 & APT300 Anchor Pull-Out Tester Malaysia, current quotation, model selection and professional construction testing equipment enquiries, contact MTM Precision.

12 Aug 2026