What Is a Good Anchor Pull-Out Test Result? How Many kN Is Considered Acceptable Malaysia
What Is a Good Anchor Pull-Out Test Result? How Many kN Is Considered Acceptable Malaysia
What Is a Good Anchor Pull-Out Test Result?
A common question is:
“What is a good pull-out test result?”
or:
“How many kN should an anchor achieve?”
There is no single kN value that is considered “good” for every anchor.
A result should be evaluated against the approved project test requirement and acceptance criteria.
For one project, a required proof load may be 40kN.
For another, it may be 80kN, 120kN or another value.
Therefore, a force reading is only meaningful when compared with the correct test requirement.
Good Result Does Not Mean Highest kN
A higher force reading is not automatically better.
Suppose a project requires:
Proof Load: 60kN
If the anchor successfully reaches and satisfies the specified 60kN proof-test criteria, there may be no reason to continue loading simply to obtain a higher number.
The goal is to perform the approved test correctly.
Example 1 – Required Load 50kN
Suppose:
Required Proof Load: 50kN
Maximum Applied Load: 50.5kN
If the anchor also satisfies all other defined criteria, this may be an acceptable result.
But do not assess the number in isolation.
Check:
Holding time
Movement where required
Visible condition
Approved acceptance criteria
Example 2 – Required Load 100kN
Suppose:
Required Load: 100kN
Maximum Achieved: 78kN
The anchor did not reach the required load.
A value of 78kN may sound high, but it does not satisfy a 100kN requirement.
This is why there is no universal “good kN” value.
Example 3 – 40kN Can Be Better Than 90kN
Imagine two different projects.
Project A
Required proof load:
40kN
Result:
40.2kN
All acceptance criteria satisfied.
Project B
Required proof load:
100kN
Result:
90kN
The second reading is numerically higher, but Project B may still fail its required test.
A “good result” depends on the requirement, not on the largest number.
Example 4 – Target Load Reached but Movement Too High
Suppose:
Required Load: 80kN
Applied Load: 80.4kN
However, the anchor shows movement beyond a limit defined by the approved procedure.
The anchor should not automatically be marked PASS.
Force is only one part of the result.
Example 5 – Target Load Reached but Concrete Cracks
Suppose the anchor reaches the required load, but significant concrete cracking or another unacceptable condition occurs.
Whether the result is acceptable depends on the project's defined criteria.
Again:
Target kN reached ≠ automatic PASS
What Determines an Acceptable Pull-Out Test Result?
Depending on the approved procedure, acceptance may include:
Required load achieved
Required holding time completed
Movement within specified limit
No unacceptable anchor slip
No unacceptable concrete damage
No other defined failure
The specific criteria vary by project.
Who Determines the Required kN?
The test operator should not invent the force.
The required test load may be defined by:
Structural engineer
Façade engineer
Consultant
Project specification
Approved method statement
Approved anchor design
Applicable test procedure
Always confirm the latest approved requirement before testing.
What Does the Pull-Out Tester Actually Tell You?
The instrument measures the applied tensile force.
For example:
72.4kN
The equipment does not automatically know:
Design load
Proof-load requirement
Acceptance criteria
Whether the anchor should pass
Whether a movement limit was exceeded
Engineering interpretation comes from the project requirements.
What Does kN Mean?
kN means:
kilonewton
It is a unit of force.
For approximate reference:
10kN ≈ 1.02 tonnes-force
50kN ≈ 5.1 tonnes-force
100kN ≈ 10.2 tonnes-force
200kN ≈ 20.4 tonnes-force
For engineering reporting, it is usually better to keep the result in the specified unit, commonly kN.
Is 20kN a Good Pull-Out Result?
Maybe.
If the approved test requirement is below or around that level and all acceptance criteria are satisfied, it may be acceptable.
If the project requires 50kN, then 20kN is not sufficient.
The number cannot be interpreted without the requirement.
Is 50kN a Good Pull-Out Result?
Again, it depends.
50kN may be:
More than enough for one application
Exactly the required proof load for another
Insufficient for a higher-load project
Never compare the number without context.
Is 100kN a Good Pull-Out Result?
100kN is a substantial force, but this does not automatically make it a PASS.
If the project requires:
120kN
then 100kN is below the required load.
If the project requires:
80kN
then testing to 100kN may not even have been necessary unless the approved procedure required it.
Is 200kN a Good Result?
200kN is approximately a 20-ton class force.
But the same principle applies.
A tester such as the Langry APT200 can measure up to 200kN.
That does not mean:
200kN is the ideal result for every anchor.
200kN is the equipment's maximum measurement range.
Do Not Test to the Maximum Just to Get a “Better” Result
This is a common misunderstanding.
If the approved proof load is 75kN, deliberately continuing to 150kN or 200kN just to show a stronger number may:
Deviate from the approved procedure
Damage the anchor
Change the installation condition
Create unnecessary safety risk
Follow the specified test.
Proof Load vs Ultimate Load
A good result also depends on the test objective.
Proof Load Test
The anchor is tested to a specified load according to the approved procedure.
The objective is generally verification.
Ultimate / Failure Test
The test continues toward a defined failure condition.
The objective is different.
Do not compare proof-test results directly with destructive test values without understanding the test method.
What Should Be Written in the Report?
A useful report should not show only:
Result: 75kN
It should include context such as:
ItemExampleAnchor IDA-01Required Load75kNMaximum Applied Load75.4kNHolding TimeAs specifiedObservationNo abnormal conditionResultAssess per approved criteria
This is much more informative.
Why Holding Time Can Matter
Some procedures require the anchor to maintain the target force for a specified period.
If the target force is reached only momentarily, the test may not satisfy the procedure.
Therefore, a “good reading” should be considered together with the full loading sequence.
Why Movement Can Matter
Some projects define allowable anchor movement or displacement.
An anchor can reach the required kN and still fail another acceptance criterion.
Where movement is part of the test, it should be measured and recorded appropriately.
Why Failure Mode Matters
For tests performed toward failure, the maximum force is only part of the result.
Also record whether failure involved:
Anchor pull-out
Bond-related failure
Concrete breakout
Steel failure
Connection failure
Different failure modes provide different engineering information.
How to Compare Two Anchor Test Results
Suppose:
Anchor A
Required: 60kN
Result: 60.3kN
No abnormal observation
Anchor B
Required: 60kN
Result: 72kN
Concrete cracking observed
You should not automatically say Anchor B is “better” because it reached a higher force.
The complete acceptance criteria must be considered.
What About Test Results Very Close to the Target?
Suppose:
Required Load: 100kN
Measured: 99.6kN
Do not simply round the number to 100kN.
Whether the result is acceptable depends on:
Approved procedure
Measurement considerations
Project criteria
The actual measured value should be recorded.
Why Tester Calibration Matters
When results are being compared to a defined acceptance threshold, confidence in the force measurement is important.
Depending on project requirements, check:
Tester serial number
Calibration status
Calibration documentation
Equipment condition
Professional interpretation depends on reliable measurement.
Langry APT200 for Anchor Pull-Out Testing
For suitable professional applications, the Langry APT200 provides:
Measurement Range: 0–200kN
approximately:
20-ton class capacity
The system is suitable for anchor pull-out testing applications where the required load and physical test configuration fall within its capability.
Selecting the Right Tester Range
Langry offers:
ModelMaximum RangeAPT100100kNAPT200200kNAPT300300kN
The correct model should be selected according to the maximum required testing range.
Frequently Asked Questions
What is a good anchor pull-out test result?
A good result is one that satisfies the approved project test requirements and acceptance criteria. There is no universal kN value.
Is 50kN good?
It depends on the required load for the specific anchor and project.
Is 100kN strong?
100kN is a substantial force, but whether it is acceptable depends on the project requirement.
Does reaching the target load automatically mean PASS?
Not always. Holding time, movement and visible behaviour may also be part of the acceptance criteria.
Is a higher kN always better?
No. The objective is to follow the approved testing procedure, not to obtain the highest possible force reading.
Should I test every anchor to the maximum tester capacity?
No. Tester capacity and required test load are different.
Who decides the required load?
The appropriate project engineer, consultant or approved project documentation should define it.
Can Langry APT200 measure up to 200kN?
Yes. The APT200 provides a maximum measurement range of 200kN.
Where can I buy anchor pull-out testing equipment in Malaysia?
Contact MTM Precision Sdn. Bhd. for Langry APT-series model selection and current quotation in Malaysia.
Anchor Pull-Out Test Equipment Malaysia
MTM Precision supplies professional construction and civil engineering testing equipment for:
Main contractors
Structural contractors
Façade contractors
QA/QC teams
Inspection companies
Testing laboratories
For equipment selection, provide:
Anchor Type + Anchor Size + Required Test Load + Application
This helps determine whether the Langry APT100, APT200 or APT300 is appropriate.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
For Langry Anchor Pull-Out Tester Malaysia, model selection, current quotation and professional construction testing equipment enquiries, contact MTM Precision.
12 Aug 2026