In industrial UV LED curing, product quality depends on more than simply switching on the UV lamp.

 

A curing machine may display the same power setting every day, yet the actual UV exposure reaching the product can change because of equipment condition, conveyor speed, lamp distance, contamination or maintenance.

 

For manufacturers using UV LED curing, measuring the process provides a stronger basis for quality control than relying only on machine settings.

 

The Linshang LS137 UV Energy Meter can measure UV energy, UV irradiance and temperature, making it useful for QA/QC and production-process monitoring.

 

Why Should UV Curing Be Part of Quality Control?

 

Manufacturers normally control important production parameters such as:

 

Temperature

 

Pressure

 

Speed

 

Time

 

Material thickness

 

Dimensions

 

If UV curing is critical to the finished product, UV exposure should also be considered as a measurable process parameter.

 

Depending on the application, insufficient or inconsistent UV curing can contribute to:

 

Tacky ink

 

Poor coating hardness

 

Weak adhesion

 

Incomplete bonding

 

Scratching

 

Smearing

 

Inconsistent surface finish

 

Product rejection

 

Rework

 

Measurement helps QA teams determine whether the UV process remains consistent.

 

Machine Settings Are Not the Same as UV Measurements

 

A UV curing machine may display:

 

Power = 80%

 

This tells the operator the machine setting.

 

It does not directly tell QA:

 

Actual UV irradiance at the product

 

Peak irradiance during curing

 

Accumulated UV energy

 

Exposure duration

 

Two machines can both display 80% while producing different measured UV conditions.

 

This is why an independent UV energy meter can be useful.

 

What Can Linshang LS137 Measure?

 

The Linshang LS137 provides several important parameters:

 

UV Energy

 

UV Irradiance

 

Peak UV Irradiance

 

Measurement Duration

 

Temperature

 

Maximum Temperature

 

These measurements allow manufacturers to create a record of actual UV curing conditions.

 

Designed for UV LED Curing

 

The LS137 is intended for UV LED light sources.

 

Its spectral response is approximately:

 

340–420 nm

 

The instrument is calibrated using a:

 

395 nm UV LED source

 

It is therefore particularly relevant to modern UV LED curing applications.

 

Common industrial UV LED wavelengths include:

 

365 nm

 

385 nm

 

395 nm

 

405 nm

 

Always confirm the actual wavelength before selecting a UV meter.

 

Step 1 – Identify a Known-Good Production Condition

 

The first step in UV curing quality control is to identify production conditions where finished-product quality is acceptable.

 

For example:

 

Adhesion passes

 

Coating hardness passes

 

Ink is fully cured

 

Bond strength passes

 

Surface quality passes

 

Measure the UV conditions during this successful production.

 

This becomes your reference.

 

Step 2 – Establish a UV Baseline

 

Record:

 

UV wavelength

 

Peak UV irradiance

 

Accumulated UV energy

 

Exposure duration

 

Maximum temperature

 

UV power setting

 

Conveyor speed

 

Lamp distance

 

Product type

 

Material

 

QA result

 

This creates a known-good UV curing baseline.

 

Future measurements now have something meaningful to compare against.

 

Step 3 – Create a Repeatable Measurement Procedure

 

For QA data to be useful, measurements should be taken under consistent conditions.

 

Define:

 

Measurement position

 

Measurement direction

 

UV power setting

 

Conveyor speed

 

Lamp distance

 

Active UV modules

 

Measurement procedure

 

If these variables change randomly, historical readings may be difficult to compare.

 

Consistency is essential.

 

Step 4 – Establish an Inspection Frequency

 

There is no universal interval suitable for every factory.

 

Depending on production requirements, UV checks might be performed:

 

At machine setup

 

At the start of a production batch

 

Weekly

 

Monthly

 

Quarterly

 

According to operating hours

 

After maintenance

 

After UV LED replacement

 

Critical processes may require more frequent verification.

 

Step 5 – Compare Against the Baseline

 

Suppose the baseline UV energy was established during good production.

 

Several months later, the reading changes significantly.

 

QA now has objective information showing that the curing process is no longer operating under the same UV conditions.

 

The production and maintenance teams can investigate before the problem becomes more serious.

 

Example: Printing Quality Control

 

A printing company uses a 395 nm UV LED curing machine.

 

During process qualification, the company records:

 

UV energy

 

Peak irradiance

 

Conveyor speed

 

UV power setting

 

Exposure duration

 

The corresponding print quality is acceptable.

 

These values become the production reference.

 

Later, if ink becomes tacky or scratches easily, QA can compare current UV readings with the original baseline.

 

This helps determine whether the curing system has changed.

 

Example: UV Coating QA

 

A manufacturer applies UV coating to industrial components.

 

Quality requirements include:

 

Surface hardness

 

Adhesion

 

Appearance

 

Scratch resistance

 

Instead of checking only the finished coating, the company can also monitor the UV curing conditions that contribute to the final result.

 

This adds another layer of process control.

 

Example: Electronics Manufacturing

 

An electronics factory uses UV adhesive for precision component bonding.

 

If the bond is important to product reliability, waiting for bond failures is not an ideal method of controlling the curing process.

 

Periodic UV measurement can help verify that the curing station continues to operate under conditions comparable with the qualified process.

 

UV Energy as a Process Parameter

 

For many curing applications, accumulated UV energy is particularly useful.

 

Consider a conveyor line.

 

If conveyor speed increases:

 

Exposure time decreases.

 

Even if peak UV irradiance remains similar, accumulated energy can decrease.

 

QA may therefore need to consider:

 

Peak UV Irradiance + UV Energy + Exposure Time

 

rather than only one measurement.

 

Use Product Quality Together with UV Measurements

 

A UV energy meter should not be used in isolation.

 

The best approach combines:

 

UV measurement data

 

with

 

actual product-quality results.

 

For example:

 

UV ConditionProduct ResultKnown-good baselinePassSimilar to baselinePassSignificant changeInvestigateAfter correctionVerify

 

Over time, this can help the company understand the relationship between UV conditions and product performance.

 

Establishing Internal Acceptance Limits

 

After collecting sufficient data, a manufacturer may establish its own acceptable operating range.

 

For example:

 

Minimum acceptable UV energy

 

Expected peak irradiance range

 

Acceptable exposure duration

 

Maximum process temperature

 

These limits should come from:

 

Process qualification

 

Material requirements

 

Product testing

 

Equipment recommendations

 

Historical production data

 

There is no single universal LS137 reading suitable for every UV curing application.

 

What If the UV Reading Is Outside the Normal Range?

 

Do not immediately replace the UV LED module.

 

First investigate possible causes such as:

 

UV LED aging

 

Dirty optical surfaces

 

Cooling problems

 

Changed power setting

 

Changed conveyor speed

 

Changed lamp distance

 

Mechanical alignment

 

Power-supply issues

 

After corrective action, measure again.

 

This creates a useful:

 

Detect → Correct → Verify

 

quality-control cycle.

 

What If UV Measurements Are Normal but the Product Fails?

 

This is equally useful information.

 

If UV readings remain comparable with the known-good baseline, QA can investigate other variables such as:

 

Ink formulation

 

Coating formulation

 

Adhesive

 

Substrate

 

Material thickness

 

Surface preparation

 

Material storage

 

Dispensing process

 

Measurement can therefore help eliminate UV exposure as the likely cause.

 

Comparing Multiple Production Machines

 

A factory may operate several similar UV curing machines.

 

Instead of assuming:

 

Machine A at 80% = Machine B at 80%

 

measure each machine independently.

 

Create a baseline for:

 

Machine A

 

Machine B

 

Machine C

 

This makes cross-line troubleshooting much easier.

 

Measure After Maintenance

 

UV measurement should be considered after work involving:

 

UV LED replacement

 

Optical cleaning

 

Cooling-system repair

 

Conveyor adjustment

 

Fixture modification

 

Power-system repair

 

Mechanical realignment

 

The objective is to verify that the process has returned to the expected operating condition.

 

Measure After Process Changes

 

QA should also consider verification after changes to:

 

Conveyor speed

 

Exposure time

 

UV power

 

Lamp distance

 

Number of active UV modules

 

Product position

 

A production change should ideally be evaluated using both measurement data and finished-product testing.

 

LS137 High-Intensity Measurement Capability

 

Modern industrial UV LED curing systems can generate high irradiance.

 

The Linshang LS137 supports UV irradiance measurement up to:

 

40,000 mW/cm²

 

This makes it suitable for many high-intensity UV LED curing applications within its specified operating conditions.

 

Suggested UV QA Record

 

A basic UV curing inspection record can include:

 

Date:

Machine ID:

Product:

UV wavelength:

UV power setting:

Conveyor speed:

Peak UV irradiance:

Accumulated UV energy:

Exposure duration:

Maximum temperature:

Operator:

QA result: Pass / Investigate

 

Keeping this information creates valuable historical data.

 

Who Can Use LS137 for Quality Control?

 

The LS137 can be useful for:

 

QA Engineers

 

QC Technicians

 

Process Engineers

 

Production Engineers

 

Maintenance Engineers

 

Equipment Engineers

 

R&D Teams

 

Potential industries include:

 

Printing

 

Packaging

 

UV coating

 

Electronics

 

PCB manufacturing

 

Adhesive bonding

 

Precision manufacturing

 

Automated production

 

LS137 or LS136?

 

The correct model depends on the UV source.

 

UV LED curing system

 

→ Consider Linshang LS137

 

Traditional high-pressure mercury UV curing lamp

 

→ Consider Linshang LS136

 

The measurement instrument should be matched to the light-source technology.

 

From Final Inspection to Process Control

 

Checking only the finished product is reactive.

 

If the product fails, the loss has already occurred.

 

Adding UV measurement allows manufacturers to monitor one of the variables responsible for curing quality.

 

A stronger QA approach is:

 

Establish Baseline → Measure Periodically → Record → Compare → Detect Change → Correct → Verify

 

This turns UV curing into a measurable production parameter.

 

Looking for Linshang LS137 for QA/QC in Malaysia?

 

MTM Precision supplies industrial testing and measurement instruments for manufacturing, engineering, maintenance and quality-control applications in Malaysia.

 

If your company uses UV LED curing and wants to establish a more structured UV quality-control process, provide us with:

 

UV wavelength

 

UV source type

 

Curing machine model

 

Application

 

Expected UV intensity

 

Production process

 

We can assist you in determining whether the Linshang LS137 UV Energy Meter is suitable for your application.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd.

 

Showroom & Service Centre

 

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia

 

🌐 Website: www.mtmpre.com.my

📧 Email: mtmpre@yahoo.com

📱 WhatsApp: +6016-660 7346

 

Contact MTM Precision for Linshang LS137 UV Energy Meter enquiries, technical information and quotation in Malaysia.


 

13 Aug 2026