In industrial UV LED curing, product quality depends on more than simply switching on the UV lamp.
A curing machine may display the same power setting every day, yet the actual UV exposure reaching the product can change because of equipment condition, conveyor speed, lamp distance, contamination or maintenance.
For manufacturers using UV LED curing, measuring the process provides a stronger basis for quality control than relying only on machine settings.
The Linshang LS137 UV Energy Meter can measure UV energy, UV irradiance and temperature, making it useful for QA/QC and production-process monitoring.
Why Should UV Curing Be Part of Quality Control?
Manufacturers normally control important production parameters such as:
Temperature
Pressure
Speed
Time
Material thickness
Dimensions
If UV curing is critical to the finished product, UV exposure should also be considered as a measurable process parameter.
Depending on the application, insufficient or inconsistent UV curing can contribute to:
Tacky ink
Poor coating hardness
Weak adhesion
Incomplete bonding
Scratching
Smearing
Inconsistent surface finish
Product rejection
Rework
Measurement helps QA teams determine whether the UV process remains consistent.
Machine Settings Are Not the Same as UV Measurements
A UV curing machine may display:
Power = 80%
This tells the operator the machine setting.
It does not directly tell QA:
Actual UV irradiance at the product
Peak irradiance during curing
Accumulated UV energy
Exposure duration
Two machines can both display 80% while producing different measured UV conditions.
This is why an independent UV energy meter can be useful.
What Can Linshang LS137 Measure?
The Linshang LS137 provides several important parameters:
UV Energy
UV Irradiance
Peak UV Irradiance
Measurement Duration
Temperature
Maximum Temperature
These measurements allow manufacturers to create a record of actual UV curing conditions.
Designed for UV LED Curing
The LS137 is intended for UV LED light sources.
Its spectral response is approximately:
340–420 nm
The instrument is calibrated using a:
395 nm UV LED source
It is therefore particularly relevant to modern UV LED curing applications.
Common industrial UV LED wavelengths include:
365 nm
385 nm
395 nm
405 nm
Always confirm the actual wavelength before selecting a UV meter.
Step 1 – Identify a Known-Good Production Condition
The first step in UV curing quality control is to identify production conditions where finished-product quality is acceptable.
For example:
Adhesion passes
Coating hardness passes
Ink is fully cured
Bond strength passes
Surface quality passes
Measure the UV conditions during this successful production.
This becomes your reference.
Step 2 – Establish a UV Baseline
Record:
UV wavelength
Peak UV irradiance
Accumulated UV energy
Exposure duration
Maximum temperature
UV power setting
Conveyor speed
Lamp distance
Product type
Material
QA result
This creates a known-good UV curing baseline.
Future measurements now have something meaningful to compare against.
Step 3 – Create a Repeatable Measurement Procedure
For QA data to be useful, measurements should be taken under consistent conditions.
Define:
Measurement position
Measurement direction
UV power setting
Conveyor speed
Lamp distance
Active UV modules
Measurement procedure
If these variables change randomly, historical readings may be difficult to compare.
Consistency is essential.
Step 4 – Establish an Inspection Frequency
There is no universal interval suitable for every factory.
Depending on production requirements, UV checks might be performed:
At machine setup
At the start of a production batch
Weekly
Monthly
Quarterly
According to operating hours
After maintenance
After UV LED replacement
Critical processes may require more frequent verification.
Step 5 – Compare Against the Baseline
Suppose the baseline UV energy was established during good production.
Several months later, the reading changes significantly.
QA now has objective information showing that the curing process is no longer operating under the same UV conditions.
The production and maintenance teams can investigate before the problem becomes more serious.
Example: Printing Quality Control
A printing company uses a 395 nm UV LED curing machine.
During process qualification, the company records:
UV energy
Peak irradiance
Conveyor speed
UV power setting
Exposure duration
The corresponding print quality is acceptable.
These values become the production reference.
Later, if ink becomes tacky or scratches easily, QA can compare current UV readings with the original baseline.
This helps determine whether the curing system has changed.
Example: UV Coating QA
A manufacturer applies UV coating to industrial components.
Quality requirements include:
Surface hardness
Adhesion
Appearance
Scratch resistance
Instead of checking only the finished coating, the company can also monitor the UV curing conditions that contribute to the final result.
This adds another layer of process control.
Example: Electronics Manufacturing
An electronics factory uses UV adhesive for precision component bonding.
If the bond is important to product reliability, waiting for bond failures is not an ideal method of controlling the curing process.
Periodic UV measurement can help verify that the curing station continues to operate under conditions comparable with the qualified process.
UV Energy as a Process Parameter
For many curing applications, accumulated UV energy is particularly useful.
Consider a conveyor line.
If conveyor speed increases:
Exposure time decreases.
Even if peak UV irradiance remains similar, accumulated energy can decrease.
QA may therefore need to consider:
Peak UV Irradiance + UV Energy + Exposure Time
rather than only one measurement.
Use Product Quality Together with UV Measurements
A UV energy meter should not be used in isolation.
The best approach combines:
UV measurement data
with
actual product-quality results.
For example:
UV ConditionProduct ResultKnown-good baselinePassSimilar to baselinePassSignificant changeInvestigateAfter correctionVerify
Over time, this can help the company understand the relationship between UV conditions and product performance.
Establishing Internal Acceptance Limits
After collecting sufficient data, a manufacturer may establish its own acceptable operating range.
For example:
Minimum acceptable UV energy
Expected peak irradiance range
Acceptable exposure duration
Maximum process temperature
These limits should come from:
Process qualification
Material requirements
Product testing
Equipment recommendations
Historical production data
There is no single universal LS137 reading suitable for every UV curing application.
What If the UV Reading Is Outside the Normal Range?
Do not immediately replace the UV LED module.
First investigate possible causes such as:
UV LED aging
Dirty optical surfaces
Cooling problems
Changed power setting
Changed conveyor speed
Changed lamp distance
Mechanical alignment
Power-supply issues
After corrective action, measure again.
This creates a useful:
Detect → Correct → Verify
quality-control cycle.
What If UV Measurements Are Normal but the Product Fails?
This is equally useful information.
If UV readings remain comparable with the known-good baseline, QA can investigate other variables such as:
Ink formulation
Coating formulation
Adhesive
Substrate
Material thickness
Surface preparation
Material storage
Dispensing process
Measurement can therefore help eliminate UV exposure as the likely cause.
Comparing Multiple Production Machines
A factory may operate several similar UV curing machines.
Instead of assuming:
Machine A at 80% = Machine B at 80%
measure each machine independently.
Create a baseline for:
Machine A
Machine B
Machine C
This makes cross-line troubleshooting much easier.
Measure After Maintenance
UV measurement should be considered after work involving:
UV LED replacement
Optical cleaning
Cooling-system repair
Conveyor adjustment
Fixture modification
Power-system repair
Mechanical realignment
The objective is to verify that the process has returned to the expected operating condition.
Measure After Process Changes
QA should also consider verification after changes to:
Conveyor speed
Exposure time
UV power
Lamp distance
Number of active UV modules
Product position
A production change should ideally be evaluated using both measurement data and finished-product testing.
LS137 High-Intensity Measurement Capability
Modern industrial UV LED curing systems can generate high irradiance.
The Linshang LS137 supports UV irradiance measurement up to:
40,000 mW/cm²
This makes it suitable for many high-intensity UV LED curing applications within its specified operating conditions.
Suggested UV QA Record
A basic UV curing inspection record can include:
Date:
Machine ID:
Product:
UV wavelength:
UV power setting:
Conveyor speed:
Peak UV irradiance:
Accumulated UV energy:
Exposure duration:
Maximum temperature:
Operator:
QA result: Pass / Investigate
Keeping this information creates valuable historical data.
Who Can Use LS137 for Quality Control?
The LS137 can be useful for:
QA Engineers
QC Technicians
Process Engineers
Production Engineers
Maintenance Engineers
Equipment Engineers
R&D Teams
Potential industries include:
Printing
Packaging
UV coating
Electronics
PCB manufacturing
Adhesive bonding
Precision manufacturing
Automated production
LS137 or LS136?
The correct model depends on the UV source.
UV LED curing system
→ Consider Linshang LS137
Traditional high-pressure mercury UV curing lamp
→ Consider Linshang LS136
The measurement instrument should be matched to the light-source technology.
From Final Inspection to Process Control
Checking only the finished product is reactive.
If the product fails, the loss has already occurred.
Adding UV measurement allows manufacturers to monitor one of the variables responsible for curing quality.
A stronger QA approach is:
Establish Baseline → Measure Periodically → Record → Compare → Detect Change → Correct → Verify
This turns UV curing into a measurable production parameter.
Looking for Linshang LS137 for QA/QC in Malaysia?
MTM Precision supplies industrial testing and measurement instruments for manufacturing, engineering, maintenance and quality-control applications in Malaysia.
If your company uses UV LED curing and wants to establish a more structured UV quality-control process, provide us with:
UV wavelength
UV source type
Curing machine model
Application
Expected UV intensity
Production process
We can assist you in determining whether the Linshang LS137 UV Energy Meter is suitable for your application.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
Contact MTM Precision for Linshang LS137 UV Energy Meter enquiries, technical information and quotation in Malaysia.
13 Aug 2026