How to Check UV LED Lamp Aging and Output Degradation with Linshang LS137 Malaysia
How to Check UV LED Lamp Aging and Output Degradation with Linshang LS137 Malaysia
UV LED curing systems are known for long operating life, stable performance and lower maintenance requirements compared with many traditional UV lamp technologies.
However, long life does not mean that UV output will remain exactly unchanged forever.
For industrial printing, coating, adhesive curing and electronics manufacturing, gradual changes in UV output can eventually affect production quality.
The Linshang LS137 UV Energy Meter provides a practical way to monitor UV irradiance and accumulated UV energy so manufacturers can compare current UV LED performance against previous measurements.
Does a UV LED Lamp Become Weaker Over Time?
Yes, UV LED output can change over its operating life.
The rate of change depends on many factors, including:
Operating hours
LED quality
Operating temperature
Cooling efficiency
Driving current
Power-supply condition
Environmental conditions
Optical contamination
Equipment maintenance
The UV LED may continue turning on normally even when its actual measured output has changed.
This is why visual inspection alone cannot determine the condition of a UV curing system.
UV LED Aging Is Often Gradual
A sudden lamp failure is easy to identify.
The machine stops curing or the UV source does not operate.
Gradual degradation is more difficult.
For example:
New UV LED
→ Production quality is good.
After several months
→ Still good.
Later
→ Slight curing inconsistency begins.
Eventually
→ Reject rate increases.
If UV output is never measured, the production team may not realize that the curing condition has gradually changed.
“The Lamp Is Still Bright” Is Not a Measurement
Operators may say:
“The UV lamp still looks bright.”
But the human eye cannot determine:
UV irradiance in mW/cm²
Accumulated UV energy in mJ/cm²
Peak UV irradiance
UV output trend
A UV LED system should therefore be evaluated using measurement data when curing performance is important.
What Does Linshang LS137 Measure?
The Linshang LS137 is designed for UV LED curing systems and can measure:
UV Energy
UV Irradiance
Peak UV Irradiance
Measurement Duration
Temperature
Maximum Temperature
These parameters can help users compare UV performance over time.
Spectral Response of the LS137
The LS137 has a spectral response range of approximately:
340–420 nm
It is calibrated using a:
395 nm UV LED source
This makes it particularly relevant to modern industrial UV LED curing equipment, especially systems operating around 395 nm.
Before purchasing, users should confirm the wavelength of their UV source.
How to Monitor UV LED Aging
The most effective method is not to wait until the UV LED becomes old.
Start measuring when the system is performing well.
Step 1 – Establish a Baseline
When the UV LED system is new or known to be operating correctly, measure and record:
UV peak irradiance
Accumulated UV energy
Exposure duration
Maximum temperature
Also record the machine settings.
This becomes the baseline.
Step 2 – Repeat Under Similar Conditions
At scheduled intervals, repeat the measurement using comparable:
UV power settings
Conveyor speed
Lamp distance
Measurement position
Machine configuration
Consistency is essential if readings are to be compared meaningfully.
Step 3 – Track the Trend
Compare each new measurement with earlier results.
The objective is not only to ask:
“What is today's UV reading?”
but:
“How has the UV output changed over time?”
Example of UV Output Trending
A company may create a simple internal record:
InspectionUV PerformanceNew UV LEDBaselineMonth 3StableMonth 6StableMonth 9Slight decreaseMonth 12Further decreaseMonth 15Review required
The exact acceptable values depend on the curing process.
There is no universal percentage that determines when every UV LED module should be replaced.
Why Baseline Measurement Is So Important
Suppose a technician measures a UV LED lamp today and gets a particular reading.
Is that reading good?
Without reference data, it may be difficult to know.
But if the same machine was measured six months earlier under comparable conditions, the technician can determine whether output has changed.
This is why historical measurement data is often more useful than an isolated reading.
UV LED Aging vs Optical Contamination
A lower UV reading does not automatically prove that the UV LED itself has degraded.
Reduced measured output can also result from:
Dirty optical windows
Ink mist
Coating residue
Dust
Incorrect distance
Mechanical changes
Before replacing a UV LED module, investigate the complete optical path.
Measure Before and After Cleaning
One useful maintenance technique is:
Measure → Clean → Measure Again
If UV output improves substantially after proper cleaning, contamination may have been a significant factor.
If the reading remains low, further investigation may be required.
This can help prevent unnecessary replacement of expensive UV LED modules.
UV LED Aging vs Cooling Problems
UV LEDs depend heavily on thermal management.
Cooling problems may affect performance.
Possible issues include:
Blocked air filters
Fan failure
Reduced airflow
Chiller problems
Water-cooling problems
Dirty heat exchangers
If UV output changes, the cooling system should also be checked according to the equipment manufacturer's maintenance procedure.
Temperature Data Can Help
The LS137 also records temperature and maximum temperature during measurement.
This does not replace dedicated thermal diagnostics, but it provides additional information about conditions during the curing cycle.
If temperature behaviour changes together with UV performance, technicians may have another reason to investigate the system.
Example: UV Printing Machine
A printing company records UV measurements when its 395 nm UV LED curing system is new.
Twelve months later, operators begin noticing occasional tacky ink.
A new LS137 measurement shows lower UV energy than the original baseline.
The team can investigate:
Conveyor speed
UV power setting
Optical cleanliness
Cooling
Lamp distance
UV LED condition
Instead of immediately changing the ink, the UV curing system can be evaluated systematically.
Example: UV Coating Line
A coating line has operated successfully for thousands of hours.
Surface hardness gradually becomes less consistent.
The company compares current UV readings against historical data.
If the UV output has gradually decreased, the maintenance team now has objective evidence that the curing system has changed.
This information can be considered together with coating-quality results.
Example: Electronics Assembly
An electronics factory uses UV adhesive for component bonding.
Because product reliability is important, the company does not want to wait until bonds begin failing.
UV measurements are incorporated into preventive process checks.
The company can then detect a gradual change before it becomes a major production issue.
How Often Should UV LED Aging Be Checked?
There is no single schedule for every application.
Possible intervals include:
Monthly
Quarterly
According to operating hours
During scheduled preventive maintenance
Before critical production runs
More important than selecting an arbitrary interval is maintaining a consistent measurement history.
High-volume or quality-critical processes may justify more frequent measurement.
Don't Compare Measurements Taken Under Different Conditions
Suppose the original reading was taken at:
UV Power = 100%
but the next reading is taken at:
UV Power = 70%
The results are not directly comparable.
The same problem occurs if:
Conveyor speed changes
Distance changes
Measurement position changes
Different UV modules are active
For meaningful aging analysis, keep important measurement conditions as consistent as practical.
Comparing New and Old UV LED Modules
When replacing a UV LED module, measure the new module under controlled conditions.
This provides useful information for:
Confirming installation
Establishing a new baseline
Comparing old vs new output
Future maintenance planning
The new measurement should then be recorded for future reference.
When Should a UV LED Module Be Replaced?
There is no universal LS137 reading that means:
“Replace the UV LED now.”
Replacement decisions should consider:
Qualified curing requirements
Material manufacturer's requirements
Product quality
Historical UV data
Maintenance findings
Equipment manufacturer's recommendations
The LS137 provides measurement data to support the decision.
It does not define the curing specification for every process.
Why Preventive Monitoring Can Save Cost
Without UV monitoring, a company may replace components based on suspicion.
For example:
Curing problem → Assume UV LED is old → Replace module
But what if the real problem was a dirty optical window or changed conveyor speed?
Measurement provides additional evidence before expensive parts are replaced.
It can also work in the opposite direction.
If measured UV output has clearly deteriorated and product quality is approaching its limit, maintenance can be planned before significant rejects occur.
LS137 Measurement Range
Industrial UV LED curing equipment can produce high irradiance.
The Linshang LS137 supports UV irradiance measurement up to:
40,000 mW/cm²
This makes it suitable for many high-intensity UV LED curing applications within its specified operating conditions.
LS137 or LS136?
The correct instrument depends on the UV source.
UV LED curing system
→ Consider Linshang LS137
Traditional high-pressure mercury UV lamp
→ Consider Linshang LS136
This distinction is important because the spectral characteristics of the two light-source technologies are different.
Applications for UV LED Aging Monitoring
The LS137 can be considered for monitoring UV LED curing systems used in:
Printing
Packaging
Label production
UV coating
Adhesive curing
Electronics manufacturing
PCB manufacturing
Optical assembly
Automated manufacturing
Industrial quality control
It can be particularly useful where curing consistency directly affects product quality.
A Better UV LED Maintenance Strategy
Instead of:
Run Until Curing Fails → Replace Parts
consider:
Measure New System → Establish Baseline → Check Periodically → Track Trend → Investigate Changes → Maintain → Verify
This gives maintenance and QA teams more information for managing UV curing equipment.
Looking for Linshang LS137 in Malaysia?
MTM Precision supplies industrial testing and measurement instruments for manufacturing, engineering, maintenance and quality-control applications in Malaysia.
If you need to monitor UV LED output degradation, provide us with:
UV wavelength
UV source type
Machine model
Application
Expected UV intensity
Production process
We can assist you in determining whether the Linshang LS137 UV Energy Meter is suitable for your UV LED curing system.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
Contact MTM Precision for Linshang LS137 UV Energy Meter enquiries, technical information and quotation in Malaysia.
13 Aug 2026