How to Check UV LED Lamp Aging and Output Degradation with Linshang LS137 Malaysia

How to Check UV LED Lamp Aging and Output Degradation with Linshang LS137 Malaysia

 

UV LED curing systems are known for long operating life, stable performance and lower maintenance requirements compared with many traditional UV lamp technologies.

 

However, long life does not mean that UV output will remain exactly unchanged forever.

 

For industrial printing, coating, adhesive curing and electronics manufacturing, gradual changes in UV output can eventually affect production quality.

 

The Linshang LS137 UV Energy Meter provides a practical way to monitor UV irradiance and accumulated UV energy so manufacturers can compare current UV LED performance against previous measurements.

 

Does a UV LED Lamp Become Weaker Over Time?

 

Yes, UV LED output can change over its operating life.

 

The rate of change depends on many factors, including:

 

Operating hours

 

LED quality

 

Operating temperature

 

Cooling efficiency

 

Driving current

 

Power-supply condition

 

Environmental conditions

 

Optical contamination

 

Equipment maintenance

 

The UV LED may continue turning on normally even when its actual measured output has changed.

 

This is why visual inspection alone cannot determine the condition of a UV curing system.

 

UV LED Aging Is Often Gradual

 

A sudden lamp failure is easy to identify.

 

The machine stops curing or the UV source does not operate.

 

Gradual degradation is more difficult.

 

For example:

 

New UV LED

 

→ Production quality is good.

 

After several months

 

→ Still good.

 

Later

 

→ Slight curing inconsistency begins.

 

Eventually

 

→ Reject rate increases.

 

If UV output is never measured, the production team may not realize that the curing condition has gradually changed.

 

“The Lamp Is Still Bright” Is Not a Measurement

 

Operators may say:

 

“The UV lamp still looks bright.”

 

But the human eye cannot determine:

 

UV irradiance in mW/cm²

 

Accumulated UV energy in mJ/cm²

 

Peak UV irradiance

 

UV output trend

 

A UV LED system should therefore be evaluated using measurement data when curing performance is important.

 

What Does Linshang LS137 Measure?

 

The Linshang LS137 is designed for UV LED curing systems and can measure:

 

UV Energy

 

UV Irradiance

 

Peak UV Irradiance

 

Measurement Duration

 

Temperature

 

Maximum Temperature

 

These parameters can help users compare UV performance over time.

 

Spectral Response of the LS137

 

The LS137 has a spectral response range of approximately:

 

340–420 nm

 

It is calibrated using a:

 

395 nm UV LED source

 

This makes it particularly relevant to modern industrial UV LED curing equipment, especially systems operating around 395 nm.

 

Before purchasing, users should confirm the wavelength of their UV source.

 

How to Monitor UV LED Aging

 

The most effective method is not to wait until the UV LED becomes old.

 

Start measuring when the system is performing well.

 

Step 1 – Establish a Baseline

 

When the UV LED system is new or known to be operating correctly, measure and record:

 

UV peak irradiance

 

Accumulated UV energy

 

Exposure duration

 

Maximum temperature

 

Also record the machine settings.

 

This becomes the baseline.

 

Step 2 – Repeat Under Similar Conditions

 

At scheduled intervals, repeat the measurement using comparable:

 

UV power settings

 

Conveyor speed

 

Lamp distance

 

Measurement position

 

Machine configuration

 

Consistency is essential if readings are to be compared meaningfully.

 

Step 3 – Track the Trend

 

Compare each new measurement with earlier results.

 

The objective is not only to ask:

 

“What is today's UV reading?”

 

but:

 

“How has the UV output changed over time?”

 

Example of UV Output Trending

 

A company may create a simple internal record:

 

InspectionUV PerformanceNew UV LEDBaselineMonth 3StableMonth 6StableMonth 9Slight decreaseMonth 12Further decreaseMonth 15Review required

 

The exact acceptable values depend on the curing process.

 

There is no universal percentage that determines when every UV LED module should be replaced.

 

Why Baseline Measurement Is So Important

 

Suppose a technician measures a UV LED lamp today and gets a particular reading.

 

Is that reading good?

 

Without reference data, it may be difficult to know.

 

But if the same machine was measured six months earlier under comparable conditions, the technician can determine whether output has changed.

 

This is why historical measurement data is often more useful than an isolated reading.

 

UV LED Aging vs Optical Contamination

 

A lower UV reading does not automatically prove that the UV LED itself has degraded.

 

Reduced measured output can also result from:

 

Dirty optical windows

 

Ink mist

 

Coating residue

 

Dust

 

Incorrect distance

 

Mechanical changes

 

Before replacing a UV LED module, investigate the complete optical path.

 

Measure Before and After Cleaning

 

One useful maintenance technique is:

 

Measure → Clean → Measure Again

 

If UV output improves substantially after proper cleaning, contamination may have been a significant factor.

 

If the reading remains low, further investigation may be required.

 

This can help prevent unnecessary replacement of expensive UV LED modules.

 

UV LED Aging vs Cooling Problems

 

UV LEDs depend heavily on thermal management.

 

Cooling problems may affect performance.

 

Possible issues include:

 

Blocked air filters

 

Fan failure

 

Reduced airflow

 

Chiller problems

 

Water-cooling problems

 

Dirty heat exchangers

 

If UV output changes, the cooling system should also be checked according to the equipment manufacturer's maintenance procedure.

 

Temperature Data Can Help

 

The LS137 also records temperature and maximum temperature during measurement.

 

This does not replace dedicated thermal diagnostics, but it provides additional information about conditions during the curing cycle.

 

If temperature behaviour changes together with UV performance, technicians may have another reason to investigate the system.

 

Example: UV Printing Machine

 

A printing company records UV measurements when its 395 nm UV LED curing system is new.

 

Twelve months later, operators begin noticing occasional tacky ink.

 

A new LS137 measurement shows lower UV energy than the original baseline.

 

The team can investigate:

 

Conveyor speed

 

UV power setting

 

Optical cleanliness

 

Cooling

 

Lamp distance

 

UV LED condition

 

Instead of immediately changing the ink, the UV curing system can be evaluated systematically.

 

Example: UV Coating Line

 

A coating line has operated successfully for thousands of hours.

 

Surface hardness gradually becomes less consistent.

 

The company compares current UV readings against historical data.

 

If the UV output has gradually decreased, the maintenance team now has objective evidence that the curing system has changed.

 

This information can be considered together with coating-quality results.

 

Example: Electronics Assembly

 

An electronics factory uses UV adhesive for component bonding.

 

Because product reliability is important, the company does not want to wait until bonds begin failing.

 

UV measurements are incorporated into preventive process checks.

 

The company can then detect a gradual change before it becomes a major production issue.

 

How Often Should UV LED Aging Be Checked?

 

There is no single schedule for every application.

 

Possible intervals include:

 

Monthly

 

Quarterly

 

According to operating hours

 

During scheduled preventive maintenance

 

Before critical production runs

 

More important than selecting an arbitrary interval is maintaining a consistent measurement history.

 

High-volume or quality-critical processes may justify more frequent measurement.

 

Don't Compare Measurements Taken Under Different Conditions

 

Suppose the original reading was taken at:

 

UV Power = 100%

 

but the next reading is taken at:

 

UV Power = 70%

 

The results are not directly comparable.

 

The same problem occurs if:

 

Conveyor speed changes

 

Distance changes

 

Measurement position changes

 

Different UV modules are active

 

For meaningful aging analysis, keep important measurement conditions as consistent as practical.

 

Comparing New and Old UV LED Modules

 

When replacing a UV LED module, measure the new module under controlled conditions.

 

This provides useful information for:

 

Confirming installation

 

Establishing a new baseline

 

Comparing old vs new output

 

Future maintenance planning

 

The new measurement should then be recorded for future reference.

 

When Should a UV LED Module Be Replaced?

 

There is no universal LS137 reading that means:

 

“Replace the UV LED now.”

 

Replacement decisions should consider:

 

Qualified curing requirements

 

Material manufacturer's requirements

 

Product quality

 

Historical UV data

 

Maintenance findings

 

Equipment manufacturer's recommendations

 

The LS137 provides measurement data to support the decision.

 

It does not define the curing specification for every process.

 

Why Preventive Monitoring Can Save Cost

 

Without UV monitoring, a company may replace components based on suspicion.

 

For example:

 

Curing problem → Assume UV LED is old → Replace module

 

But what if the real problem was a dirty optical window or changed conveyor speed?

 

Measurement provides additional evidence before expensive parts are replaced.

 

It can also work in the opposite direction.

 

If measured UV output has clearly deteriorated and product quality is approaching its limit, maintenance can be planned before significant rejects occur.

 

LS137 Measurement Range

 

Industrial UV LED curing equipment can produce high irradiance.

 

The Linshang LS137 supports UV irradiance measurement up to:

 

40,000 mW/cm²

 

This makes it suitable for many high-intensity UV LED curing applications within its specified operating conditions.

 

LS137 or LS136?

 

The correct instrument depends on the UV source.

 

UV LED curing system

 

→ Consider Linshang LS137

 

Traditional high-pressure mercury UV lamp

 

→ Consider Linshang LS136

 

This distinction is important because the spectral characteristics of the two light-source technologies are different.

 

Applications for UV LED Aging Monitoring

 

The LS137 can be considered for monitoring UV LED curing systems used in:

 

Printing

 

Packaging

 

Label production

 

UV coating

 

Adhesive curing

 

Electronics manufacturing

 

PCB manufacturing

 

Optical assembly

 

Automated manufacturing

 

Industrial quality control

 

It can be particularly useful where curing consistency directly affects product quality.

 

A Better UV LED Maintenance Strategy

 

Instead of:

 

Run Until Curing Fails → Replace Parts

 

consider:

 

Measure New System → Establish Baseline → Check Periodically → Track Trend → Investigate Changes → Maintain → Verify

 

This gives maintenance and QA teams more information for managing UV curing equipment.

 

Looking for Linshang LS137 in Malaysia?

 

MTM Precision supplies industrial testing and measurement instruments for manufacturing, engineering, maintenance and quality-control applications in Malaysia.

 

If you need to monitor UV LED output degradation, provide us with:

 

UV wavelength

 

UV source type

 

Machine model

 

Application

 

Expected UV intensity

 

Production process

 

We can assist you in determining whether the Linshang LS137 UV Energy Meter is suitable for your UV LED curing system.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd.

 

Showroom & Service Centre

 

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia

 

🌐 Website: www.mtmpre.com.my

📧 Email: mtmpre@yahoo.com

📱 WhatsApp: +6016-660 7346

 

Contact MTM Precision for Linshang LS137 UV Energy Meter enquiries, technical information and quotation in Malaysia.


 