How Often Should You Check UV LED Curing Performance? Linshang LS137 Malaysia
How Often Should You Check UV LED Curing Performance? Linshang LS137 Malaysia
A UV LED curing system may continue operating every day without showing any obvious warning signs. The lamp is still ON, the machine is running, and production continues normally.
But does this mean the UV output is still the same as when the machine was new?
Not necessarily.
For manufacturers using UV LED curing in printing, coating, adhesive bonding and electronics production, periodic UV measurement can help detect changes before they become serious quality problems.
The Linshang LS137 UV Energy Meter is designed for UV LED light sources and can measure UV energy, UV irradiance and temperature, making it useful for routine UV curing performance checks.
Does UV LED Output Stay Constant Forever?
UV LED technology generally offers long operating life, but this does not mean that curing performance should never be checked.
Actual UV output can be influenced by factors such as:
Operating hours
LED degradation
Operating temperature
Cooling-system performance
Optical contamination
Power-supply condition
Mechanical alignment
Distance from the product
Some changes may happen gradually.
Because the deterioration is slow, production operators may not notice it immediately.
Why Visual Inspection Is Not Enough
One common method of checking a UV curing system is simply looking at whether the lamp is operating.
This confirms that the system is producing light.
It does not tell you the actual:
UV irradiance
Peak UV irradiance
Accumulated UV energy
Exposure duration
A UV LED module can remain operational while its measured output differs from the original condition.
For production quality control, numerical measurements provide much more useful information.
So, How Often Should UV LED Output Be Measured?
There is no single measurement interval suitable for every factory.
The correct frequency depends on:
Production volume
Operating hours
Criticality of the curing process
Customer quality requirements
UV LED system design
Maintenance schedule
Historical stability
However, several practical measurement points can be established.
1. Measure When the Machine Is New
One of the most important measurements should be taken when:
The machine is correctly installed
Production parameters are established
Product quality is acceptable
This becomes the original baseline measurement.
Record the UV conditions when the system is known to be performing correctly.
Without this baseline, future readings are more difficult to interpret.
2. Measure After Installing a New UV LED Module
Whenever a UV LED module is replaced, measure the new system.
This provides a new reference point.
Do not assume that:
New module = exactly the same output as the previous module
Differences can exist because of equipment configuration, positioning and operating conditions.
Record the actual measured result.
3. Measure After Maintenance
UV measurement is useful after maintenance involving:
UV LED modules
Optical windows
Cooling systems
Power supplies
Conveyors
Fixtures
Mechanical alignment
The objective is to verify that the curing process has returned to an expected operating condition.
4. Measure After Cleaning
Dust, ink mist, coating residue and other contamination may affect the optical path.
For certain production environments, measurements before and after cleaning can provide useful information.
If UV irradiance increases significantly after cleaning, the company has evidence that optical contamination was affecting the curing process.
This information can also help determine an appropriate cleaning schedule.
5. Measure When Conveyor Speed Changes
Increasing conveyor speed is a common way to improve production output.
But:
Higher speed = Shorter exposure time
Shorter exposure can reduce accumulated UV energy.
Whenever production speed is significantly changed, UV energy should be checked together with product quality.
This helps ensure that increased output does not create under-curing problems.
6. Measure When UV Power Settings Change
Changing the machine from:
60% → 80%
or
80% → 100%
changes a machine setting.
But what does that change mean in actual UV irradiance?
Measurement can provide the answer.
This is particularly useful during process development and machine qualification.
7. Measure When Curing Quality Changes
If production suddenly develops problems such as:
Tacky ink
Poor coating hardness
Weak adhesive bonding
Scratching
Smearing
Incomplete curing
Increased rejection
the UV curing system should be one of the parameters investigated.
Compare current UV measurements with the known-good baseline.
8. Measure Periodically During Normal Production
Even when there are no obvious problems, periodic measurement can help establish a trend.
For example, depending on the process, a company may decide to check:
Monthly
Quarterly
According to operating hours
According to preventive-maintenance intervals
The correct schedule should be determined by the company's process requirements.
For critical curing processes, more frequent checks may be appropriate.
Why Trending Is Better Than One Measurement
A single UV measurement tells you the condition at one moment.
A series of measurements tells you the trend.
For example:
InspectionUV Output TrendInitial baseline100% referenceMonth 3StableMonth 6Slight reductionMonth 9Further reductionMonth 12Maintenance investigation required
The exact acceptable limits should be established according to the production process rather than using a universal percentage.
The important point is that trending can reveal gradual changes.
What Should Be Recorded?
A useful UV inspection record should contain more than one number.
Consider recording:
Date
Machine number
UV source wavelength
UV LED operating hours
UV power setting
Peak UV irradiance
Accumulated UV energy
Exposure duration
Maximum temperature
Conveyor speed
Lamp distance
Product
Operator
Production quality result
This creates a much stronger maintenance history.
What Can Linshang LS137 Measure?
The Linshang LS137 provides several parameters useful for UV LED curing monitoring:
UV Energy
UV Irradiance
Peak UV Irradiance
Measurement Duration
Temperature
Maximum Temperature
The instrument has a spectral response of approximately:
340–420 nm
and is calibrated using a:
395 nm UV LED source
Its UV irradiance measurement capability reaches up to:
40,000 mW/cm²
This makes it relevant to many industrial UV LED curing systems.
Example: Printing Factory
A printing factory records LS137 measurements when its 395 nm UV LED curing system is operating correctly.
The company then performs a monthly check.
For several months, the readings remain relatively stable.
Later, UV energy begins trending downward.
Before significant curing defects occur, maintenance personnel can investigate:
UV LED condition
Optical cleanliness
Cooling system
Power system
Machine settings
This is more effective than waiting until customers report printing defects.
Example: UV Coating Production
A coating company measures UV exposure every three months.
After one inspection, the UV intensity is noticeably lower than the previous baseline.
The team cleans the relevant optical components according to the equipment manufacturer's procedure and repeats the measurement.
If the reading improves, the company now has useful information for developing its preventive-maintenance schedule.
Example: Electronics Manufacturing
An electronics manufacturer uses UV adhesive in a critical assembly process.
Instead of waiting for bond failures, the company includes UV measurement in its regular process verification.
This helps ensure that the curing equipment continues operating within the company's established production window.
Create an Internal Acceptance Range
After collecting sufficient production data, companies can establish their own acceptable UV process range.
For example, QA may define:
Known-good UV energy range
Known-good peak irradiance range
Maximum acceptable temperature
These limits should be based on actual process qualification and material requirements.
The LS137 then becomes a tool for checking whether current conditions remain within that established process window.
Don't Use Another Machine as Your Only Reference
Suppose Machine A and Machine B both display:
UV Power = 80%
That does not prove their actual UV output is identical.
Differences may result from:
UV LED age
Operating hours
Cooling efficiency
Optical cleanliness
Distance
Equipment condition
Each important curing machine should ideally have its own baseline.
Preventive Maintenance vs Reactive Maintenance
Without periodic measurement, UV curing maintenance can become reactive:
Product fails → Investigate machine → Replace components → Test again
With historical measurement data, maintenance can become more preventive:
Measure → Track trend → Detect change → Investigate → Correct before major failure
For factories where curing defects cause expensive rejection or rework, this can be especially valuable.
When Should You Replace a UV LED Module?
A UV energy meter should not be used to create a universal replacement rule such as:
“Replace the lamp when it drops by X%.”
The acceptable UV output depends on the actual curing process.
A better approach is to compare measured performance against:
Qualified production parameters
Material curing requirements
Historical baseline
Product quality results
Equipment manufacturer's recommendations
Replace or service the UV system when measurement and process requirements indicate that corrective action is necessary.
LS137 or LS136 for Maintenance Checks?
First identify the light-source technology.
For:
UV LED curing → Consider Linshang LS137
For:
Traditional high-pressure mercury UV curing → Consider Linshang LS136
The measurement instrument should match the UV source.
Who Should Perform UV Checks?
Depending on the factory, UV measurement may be handled by:
Maintenance technicians
Production engineers
Process engineers
QA/QC personnel
Equipment engineers
R&D teams
The important point is to establish a consistent measurement procedure so results taken at different times can be meaningfully compared.
A Simple UV LED Maintenance Strategy
A practical approach is:
Baseline → Periodic Measurement → Record → Trend → Investigate Change → Correct → Verify
This transforms UV curing performance into a measurable maintenance parameter instead of something checked only after production problems appear.
Looking for Linshang LS137 in Malaysia?
MTM Precision supplies industrial testing and measurement instruments for manufacturing, engineering, maintenance and quality-control applications in Malaysia.
If your company operates UV LED curing equipment and wants to establish a periodic UV measurement program, provide us with:
UV wavelength
UV source type
Curing machine model
Application
Expected UV intensity
Production process
We can assist you in determining whether the Linshang LS137 UV Energy Meter is suitable for your application.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
Contact MTM Precision for Linshang LS137 UV Energy Meter enquiries, technical information and quotation in Malaysia.
13 Aug 2026