How Often Should You Check UV LED Curing Performance? Linshang LS137 Malaysia

How Often Should You Check UV LED Curing Performance? Linshang LS137 Malaysia

 

A UV LED curing system may continue operating every day without showing any obvious warning signs. The lamp is still ON, the machine is running, and production continues normally.

 

But does this mean the UV output is still the same as when the machine was new?

 

Not necessarily.

 

For manufacturers using UV LED curing in printing, coating, adhesive bonding and electronics production, periodic UV measurement can help detect changes before they become serious quality problems.

 

The Linshang LS137 UV Energy Meter is designed for UV LED light sources and can measure UV energy, UV irradiance and temperature, making it useful for routine UV curing performance checks.

 

Does UV LED Output Stay Constant Forever?

 

UV LED technology generally offers long operating life, but this does not mean that curing performance should never be checked.

 

Actual UV output can be influenced by factors such as:

 

Operating hours

 

LED degradation

 

Operating temperature

 

Cooling-system performance

 

Optical contamination

 

Power-supply condition

 

Mechanical alignment

 

Distance from the product

 

Some changes may happen gradually.

 

Because the deterioration is slow, production operators may not notice it immediately.

 

Why Visual Inspection Is Not Enough

 

One common method of checking a UV curing system is simply looking at whether the lamp is operating.

 

This confirms that the system is producing light.

 

It does not tell you the actual:

 

UV irradiance

 

Peak UV irradiance

 

Accumulated UV energy

 

Exposure duration

 

A UV LED module can remain operational while its measured output differs from the original condition.

 

For production quality control, numerical measurements provide much more useful information.

 

So, How Often Should UV LED Output Be Measured?

 

There is no single measurement interval suitable for every factory.

 

The correct frequency depends on:

 

Production volume

 

Operating hours

 

Criticality of the curing process

 

Customer quality requirements

 

UV LED system design

 

Maintenance schedule

 

Historical stability

 

However, several practical measurement points can be established.

 

1. Measure When the Machine Is New

 

One of the most important measurements should be taken when:

 

The machine is correctly installed

 

Production parameters are established

 

Product quality is acceptable

 

This becomes the original baseline measurement.

 

Record the UV conditions when the system is known to be performing correctly.

 

Without this baseline, future readings are more difficult to interpret.

 

2. Measure After Installing a New UV LED Module

 

Whenever a UV LED module is replaced, measure the new system.

 

This provides a new reference point.

 

Do not assume that:

 

New module = exactly the same output as the previous module

 

Differences can exist because of equipment configuration, positioning and operating conditions.

 

Record the actual measured result.

 

3. Measure After Maintenance

 

UV measurement is useful after maintenance involving:

 

UV LED modules

 

Optical windows

 

Cooling systems

 

Power supplies

 

Conveyors

 

Fixtures

 

Mechanical alignment

 

The objective is to verify that the curing process has returned to an expected operating condition.

 

4. Measure After Cleaning

 

Dust, ink mist, coating residue and other contamination may affect the optical path.

 

For certain production environments, measurements before and after cleaning can provide useful information.

 

If UV irradiance increases significantly after cleaning, the company has evidence that optical contamination was affecting the curing process.

 

This information can also help determine an appropriate cleaning schedule.

 

5. Measure When Conveyor Speed Changes

 

Increasing conveyor speed is a common way to improve production output.

 

But:

 

Higher speed = Shorter exposure time

 

Shorter exposure can reduce accumulated UV energy.

 

Whenever production speed is significantly changed, UV energy should be checked together with product quality.

 

This helps ensure that increased output does not create under-curing problems.

 

6. Measure When UV Power Settings Change

 

Changing the machine from:

 

60% → 80%

 

or

 

80% → 100%

 

changes a machine setting.

 

But what does that change mean in actual UV irradiance?

 

Measurement can provide the answer.

 

This is particularly useful during process development and machine qualification.

 

7. Measure When Curing Quality Changes

 

If production suddenly develops problems such as:

 

Tacky ink

 

Poor coating hardness

 

Weak adhesive bonding

 

Scratching

 

Smearing

 

Incomplete curing

 

Increased rejection

 

the UV curing system should be one of the parameters investigated.

 

Compare current UV measurements with the known-good baseline.

 

8. Measure Periodically During Normal Production

 

Even when there are no obvious problems, periodic measurement can help establish a trend.

 

For example, depending on the process, a company may decide to check:

 

Monthly

 

Quarterly

 

According to operating hours

 

According to preventive-maintenance intervals

 

The correct schedule should be determined by the company's process requirements.

 

For critical curing processes, more frequent checks may be appropriate.

 

Why Trending Is Better Than One Measurement

 

A single UV measurement tells you the condition at one moment.

 

A series of measurements tells you the trend.

 

For example:

 

InspectionUV Output TrendInitial baseline100% referenceMonth 3StableMonth 6Slight reductionMonth 9Further reductionMonth 12Maintenance investigation required

 

The exact acceptable limits should be established according to the production process rather than using a universal percentage.

 

The important point is that trending can reveal gradual changes.

 

What Should Be Recorded?

 

A useful UV inspection record should contain more than one number.

 

Consider recording:

 

Date

 

Machine number

 

UV source wavelength

 

UV LED operating hours

 

UV power setting

 

Peak UV irradiance

 

Accumulated UV energy

 

Exposure duration

 

Maximum temperature

 

Conveyor speed

 

Lamp distance

 

Product

 

Operator

 

Production quality result

 

This creates a much stronger maintenance history.

 

What Can Linshang LS137 Measure?

 

The Linshang LS137 provides several parameters useful for UV LED curing monitoring:

 

UV Energy

 

UV Irradiance

 

Peak UV Irradiance

 

Measurement Duration

 

Temperature

 

Maximum Temperature

 

The instrument has a spectral response of approximately:

 

340–420 nm

 

and is calibrated using a:

 

395 nm UV LED source

 

Its UV irradiance measurement capability reaches up to:

 

40,000 mW/cm²

 

This makes it relevant to many industrial UV LED curing systems.

 

Example: Printing Factory

 

A printing factory records LS137 measurements when its 395 nm UV LED curing system is operating correctly.

 

The company then performs a monthly check.

 

For several months, the readings remain relatively stable.

 

Later, UV energy begins trending downward.

 

Before significant curing defects occur, maintenance personnel can investigate:

 

UV LED condition

 

Optical cleanliness

 

Cooling system

 

Power system

 

Machine settings

 

This is more effective than waiting until customers report printing defects.

 

Example: UV Coating Production

 

A coating company measures UV exposure every three months.

 

After one inspection, the UV intensity is noticeably lower than the previous baseline.

 

The team cleans the relevant optical components according to the equipment manufacturer's procedure and repeats the measurement.

 

If the reading improves, the company now has useful information for developing its preventive-maintenance schedule.

 

Example: Electronics Manufacturing

 

An electronics manufacturer uses UV adhesive in a critical assembly process.

 

Instead of waiting for bond failures, the company includes UV measurement in its regular process verification.

 

This helps ensure that the curing equipment continues operating within the company's established production window.

 

Create an Internal Acceptance Range

 

After collecting sufficient production data, companies can establish their own acceptable UV process range.

 

For example, QA may define:

 

Known-good UV energy range

 

Known-good peak irradiance range

 

Maximum acceptable temperature

 

These limits should be based on actual process qualification and material requirements.

 

The LS137 then becomes a tool for checking whether current conditions remain within that established process window.

 

Don't Use Another Machine as Your Only Reference

 

Suppose Machine A and Machine B both display:

 

UV Power = 80%

 

That does not prove their actual UV output is identical.

 

Differences may result from:

 

UV LED age

 

Operating hours

 

Cooling efficiency

 

Optical cleanliness

 

Distance

 

Equipment condition

 

Each important curing machine should ideally have its own baseline.

 

Preventive Maintenance vs Reactive Maintenance

 

Without periodic measurement, UV curing maintenance can become reactive:

 

Product fails → Investigate machine → Replace components → Test again

 

With historical measurement data, maintenance can become more preventive:

 

Measure → Track trend → Detect change → Investigate → Correct before major failure

 

For factories where curing defects cause expensive rejection or rework, this can be especially valuable.

 

When Should You Replace a UV LED Module?

 

A UV energy meter should not be used to create a universal replacement rule such as:

 

“Replace the lamp when it drops by X%.”

 

The acceptable UV output depends on the actual curing process.

 

A better approach is to compare measured performance against:

 

Qualified production parameters

 

Material curing requirements

 

Historical baseline

 

Product quality results

 

Equipment manufacturer's recommendations

 

Replace or service the UV system when measurement and process requirements indicate that corrective action is necessary.

 

LS137 or LS136 for Maintenance Checks?

 

First identify the light-source technology.

 

For:

 

UV LED curing → Consider Linshang LS137

 

For:

 

Traditional high-pressure mercury UV curing → Consider Linshang LS136

 

The measurement instrument should match the UV source.

 

Who Should Perform UV Checks?

 

Depending on the factory, UV measurement may be handled by:

 

Maintenance technicians

 

Production engineers

 

Process engineers

 

QA/QC personnel

 

Equipment engineers

 

R&D teams

 

The important point is to establish a consistent measurement procedure so results taken at different times can be meaningfully compared.

 

A Simple UV LED Maintenance Strategy

 

A practical approach is:

 

Baseline → Periodic Measurement → Record → Trend → Investigate Change → Correct → Verify

 

This transforms UV curing performance into a measurable maintenance parameter instead of something checked only after production problems appear.

 

Looking for Linshang LS137 in Malaysia?

 

MTM Precision supplies industrial testing and measurement instruments for manufacturing, engineering, maintenance and quality-control applications in Malaysia.

 

If your company operates UV LED curing equipment and wants to establish a periodic UV measurement program, provide us with:

 

UV wavelength

 

UV source type

 

Curing machine model

 

Application

 

Expected UV intensity

 

Production process

 

We can assist you in determining whether the Linshang LS137 UV Energy Meter is suitable for your application.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd.

 

Showroom & Service Centre

 

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia

 

🌐 Website: www.mtmpre.com.my

📧 Email: mtmpre@yahoo.com

📱 WhatsApp: +6016-660 7346

 

Contact MTM Precision for Linshang LS137 UV Energy Meter enquiries, technical information and quotation in Malaysia.


 

13 Aug 2026