Solar Irradiance Measurement for Building and Energy Efficiency Assessment Malaysia

Solar Irradiance Measurement for Building and Energy Efficiency Assessment Malaysia

 

Solar radiation affects more than solar PV systems.

 

For commercial buildings, factories, offices and residential properties, sunlight entering through windows and striking exposed building surfaces can influence indoor heat gain, cooling requirements and overall building energy performance.

 

The TENMARS TM-207 Solar Power Meter provides a portable method for measuring solar irradiance in W/m², making it useful for preliminary building assessment, glazing comparison, solar control evaluation and energy-efficiency investigations.

 

Why Solar Radiation Matters for Buildings

 

Malaysia's tropical climate means many buildings experience strong solar exposure throughout the year.

 

Solar radiation can affect:

 

Windows and glass façades

 

Building walls

 

Rooftops

 

Skylights

 

Indoor areas near windows

 

Air-conditioning demand

 

Indoor thermal comfort

 

Large glazed surfaces can be particularly important because solar radiation entering through glass may contribute to indoor heat gain.

 

Measuring solar radiation can therefore provide useful supporting information during building and energy assessments.

 

What Does the TENMARS TM-207 Measure?

 

The TENMARS TM-207 is designed to measure solar radiation intensity.

 

It can measure up to:

 

1999 W/m²

 

Readings can be displayed in:

 

W/m²

 

BTU/(ft²·h)

 

Its spectral response is approximately 400–1100 nm.

 

The portable design allows technicians to move between different areas of a building and compare solar radiation under actual site conditions.

 

Compare Different Sides of a Building

 

Different sides of the same building can experience very different solar exposure.

 

For example, an engineer may take measurements around:

 

East-facing windows

 

West-facing windows

 

North-facing areas

 

South-facing areas

 

Rooftop locations

 

Shaded sections

 

Comparing these readings can help identify areas experiencing stronger solar radiation at the time of inspection.

 

This information may be useful when investigating heat-related complaints or planning further energy-efficiency improvements.

 

Evaluating Glass and Window Film

 

One practical application of the TM-207 is comparing solar radiation before and after it passes through glass.

 

Measurements can be taken:

 

Outside / Reference → Glass → Indoor Side

 

The same approach can be used when evaluating solar control film.

 

For example:

 

Before film installation: higher measured solar radiation

 

After film installation: lower measured solar radiation under comparable conditions

 

This provides a straightforward before-and-after comparison.

 

Building Retrofit Assessment

 

Existing buildings may undergo energy-efficiency improvements such as:

 

Installing solar control film

 

Replacing glazing

 

Adding external shading

 

Installing blinds

 

Improving insulation

 

Upgrading HVAC systems

 

Installing rooftop solar PV

 

Solar irradiance measurements can provide additional field information during these projects.

 

The TM-207 is particularly useful when the objective is to make quick comparative measurements rather than establish a permanent monitoring system.

 

HVAC Investigation

 

Solar heat gain can contribute to the cooling load of a building.

 

For example, occupants may report that one section of an office becomes significantly hotter during certain parts of the day.

 

A facility or HVAC team can investigate several factors, including:

 

Solar exposure

 

Window orientation

 

Glazing

 

Window film

 

Air-conditioning performance

 

Airflow

 

Indoor temperature

 

Humidity

 

Solar irradiance measurement adds another useful parameter to the investigation.

 

Facility Management Applications

 

Facility managers are increasingly expected to understand why certain areas consume more energy or experience different environmental conditions.

 

A portable solar power meter can be useful for quick checks around:

 

Factories

 

Warehouses

 

Office buildings

 

Shopping centres

 

Hospitals

 

Hotels

 

Schools

 

Universities

 

Government buildings

 

The instrument can be carried to different areas and used to compare actual solar exposure.

 

Solar Irradiance and Energy Audits

 

A professional energy audit normally considers many parameters.

 

Depending on the project, these may include:

 

Electricity consumption

 

Power demand

 

Lighting

 

HVAC performance

 

Temperature

 

Humidity

 

Airflow

 

Thermal imaging

 

Building envelope condition

 

Solar exposure

 

The TENMARS TM-207 does not replace a complete building energy audit.

 

Instead, it provides an additional field measurement that may help explain how solar exposure differs around the building.

 

Supporting Green Building Projects

 

Green building and sustainability projects increasingly focus on reducing unnecessary energy consumption while maintaining suitable indoor conditions.

 

Solar radiation can be relevant when assessing:

 

Building orientation

 

Glazing

 

Shading

 

Window film

 

Cooling requirements

 

Rooftop solar potential

 

Being able to measure rather than simply estimate site conditions can improve preliminary investigations.

 

Solar Irradiance and ESG

 

Energy efficiency is also connected to broader corporate sustainability and ESG initiatives.

 

Commercial and industrial facilities may seek to:

 

Reduce electricity consumption

 

Improve energy efficiency

 

Reduce cooling demand

 

Increase renewable energy use

 

Install solar PV

 

Improve environmental performance

 

Measurement instruments help turn improvement projects into measurable engineering activities.

 

The TM-207 can support specific solar radiation assessments within these wider initiatives.

 

TM-207 for Solar PV and Building Assessment

 

One advantage of the TENMARS TM-207 is that the same instrument can support several related applications.

 

Solar PV

 

Measure and compare solar irradiance at potential installation locations.

 

Building Glass

 

Compare solar radiation before and after glazing.

 

Solar Film

 

Perform before-and-after comparative measurements.

 

Building Exposure

 

Compare solar radiation around different sides of a property.

 

Energy Investigation

 

Add solar irradiance information to a broader building energy assessment.

 

This makes the instrument relevant beyond dedicated solar PV contractors.

 

Who Can Use the TENMARS TM-207?

 

Potential users include:

 

Facility managers

 

Energy managers

 

Building engineers

 

HVAC contractors

 

Energy consultants

 

Solar PV contractors

 

Building inspectors

 

Window film companies

 

Glass suppliers

 

Sustainability teams

 

Universities and technical institutions

 

Measurement Is Better Than Assumption

 

A west-facing glass façade may feel hot in the afternoon.

 

A rooftop may appear suitable for solar PV.

 

A solar film may claim to reduce incoming solar energy.

 

These observations can be useful, but measurement provides additional evidence.

 

With the TENMARS TM-207 Solar Power Meter, users can obtain solar radiation readings in W/m² and compare different locations or conditions directly.

 

For building, energy-efficiency and solar applications in Malaysia, this makes the TM-207 a useful portable measurement tool.

 

Looking for TENMARS TM-207 Solar Power Meter in Malaysia?

 

MTM Precision supplies professional testing and measurement instruments for building, HVAC, solar PV, environmental, electrical and industrial applications.

 

Contact us for TENMARS TM-207 Solar Power Meter product information, pricing and availability in Malaysia.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd.

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia

 

🌐 Website: www.mtmpre.com.my

📧 Email: mtmpre@yahoo.com

📱 WhatsApp: +6016-660 7346


 

15 Aug 2026