Why Use a 60 Degree Gloss Meter? Linshang LS190 Guide Malaysia
Why Use a 60 Degree Gloss Meter? Linshang LS190 Guide Malaysia
When choosing a gloss meter, one of the most important specifications is the measurement angle.
Gloss meters commonly use geometries such as 20°, 60° and 85°, depending on the surface and applicable testing method. Among these, 60° is widely used as a general-purpose geometry for many industrial gloss measurements.
The Linshang LS190 Gloss Meter uses a 60° measurement angle, with a 0–200 GU range and 1 GU resolution, making it a practical option for routine quality control.
What Does 60° Mean on a Gloss Meter?
A gloss meter shines light onto a surface at a defined geometry and measures the reflected light.
The measurement result is displayed in Gloss Units (GU).
The angle is important because the same surface can produce different numerical results when measured using different geometries.
Therefore, when comparing gloss readings, the measurement method must be consistent.
Why Is 60° Commonly Used?
60° is commonly treated as the general-purpose geometry for gloss measurement.
It is used for a wide range of materials and industrial surfaces where the applicable standard or product specification calls for 60° measurement.
Typical applications may include:
Paint
Industrial coatings
Plastics
Ceramics
Tiles
Paper
Printing
Packaging
Metal finishes
Furniture surfaces
This versatility is one reason a 60° gloss meter is often a practical first instrument for a factory or QA/QC department.
20°, 60° and 85°: What Is the Difference?
A simple way to understand the three common geometries is:
20°
Often associated with high-gloss surfaces where greater differentiation at the high-gloss end is required.
60°
Common general-purpose geometry used across a broad range of surfaces.
85°
Often associated with low-gloss or matte surfaces where better differentiation at the low-gloss end is needed.
However, users should not select an angle purely from a simple rule.
The applicable product standard, customer specification and surface characteristics should always be considered.
Why the LS190 Uses 60°
The LS190 is positioned as a cost-effective general-purpose gloss meter.
Its specifications are focused on straightforward industrial QC:
60° measurement geometry
0–200 GU measuring range
1 GU resolution
QC upper and lower limit setting
USB computer communication
Excel data export
This makes it particularly suitable for users who do not need a multi-angle instrument.
Example: Paint and Coating Inspection
Consider a manufacturer producing coated metal panels.
The approved sample measures:
78 GU at 60°
Production batches can then be checked using the same measurement geometry.
For example:
Batch A: 77 GU
Batch B: 80 GU
Batch C: 79 GU
Batch D: 61 GU
The results provide a straightforward indication that Batch D should be investigated.
The important point is that all samples are measured under the same defined conditions.
Example: Plastic Components
Plastic manufacturers may also use gloss measurement to monitor appearance consistency.
Changes in:
Raw material
Mould condition
Processing temperature
Surface texture
Coating
Production settings
can influence the final surface appearance.
A 60° gloss meter can provide measurable data for suitable plastic products instead of relying only on whether an operator thinks a component looks “more shiny.”
Why Consistent Measurement Geometry Matters
Suppose one supplier reports a gloss value measured at 60°, while another uses a different geometry.
The numbers should not simply be compared as though they were produced under identical conditions.
When specifying gloss requirements, companies should clearly define:
Measurement geometry
Acceptable GU range
Measurement method
Applicable standard where required
This reduces confusion between manufacturers, suppliers and customers.
Standards and 60° Gloss Measurement
The Linshang LS190 is designed according to commonly used gloss measurement standards such as:
ISO 2813
ASTM D523
DIN 67530
GB/T 9754
Standards help establish consistent measurement procedures.
Companies should confirm which standard applies to their particular material, product or customer requirement.
Is 60° Suitable for Every Surface?
No.
Although 60° is widely used, some applications are better evaluated using another measurement geometry.
Very high-gloss surfaces may require a different geometry for better differentiation.
Very low-gloss surfaces may also benefit from another measurement angle.
If your company handles a very wide variety of surfaces, a multi-angle gloss meter may be more appropriate.
When Is a Single-Angle Meter Better?
A single-angle 60° gloss meter can be an excellent choice when:
Your product specification consistently uses 60°
You perform repetitive production QC
Your products fall within the instrument's measurement range
You want straightforward operation
Multiple measurement angles are unnecessary
In these situations, buying a more complicated multi-angle instrument may add cost without improving everyday QC.
Why LS190 Can Be Suitable for SMEs
Many Malaysian SMEs do not need laboratory-level equipment for every inspection task.
Their main requirements may simply be:
Compare current production with an approved sample
Check supplier consistency
Monitor batch-to-batch variation
Establish QC acceptance limits
Record measurements
For appropriate 60° applications, the LS190 provides these capabilities in an economical package.
Using QC Upper and Lower Limits
The LS190 allows users to establish acceptable gloss limits.
For example:
Lower limit: 65 GU
Upper limit: 80 GU
The production team can then measure samples and quickly identify results outside the target range.
This can simplify repetitive inspection and reduce differences between individual operators.
USB and Excel Data Export
Measurement data can also become part of the company's quality records.
The LS190 supports USB communication with a computer and Excel data export.
Companies can use this information for:
Production records
Batch comparisons
Incoming QC
Supplier evaluation
Customer reports
Quality investigations
This is especially useful when gloss becomes a formal part of the product specification.
60° Gloss Meter or Multi-Angle Gloss Meter?
The choice depends on the application.
Choose a 60° single-angle meter when the measurement requirement is clearly defined and 60° is appropriate.
Consider a multi-angle gloss meter when:
You regularly measure very low-, medium- and high-gloss surfaces
Different customers specify different geometries
Laboratory or R&D work requires greater flexibility
Buying based on actual application requirements normally provides better value than simply selecting the instrument with the most functions.
Conclusion
A 60 degree gloss meter is widely used because it provides a practical general-purpose method for measuring surface gloss across many industrial applications.
The Linshang LS190 Gloss Meter combines 60° measurement, a 0–200 GU range, 1 GU resolution, QC limit functions and computer data management, making it suitable for routine quality control where these specifications meet the application.
For Malaysian manufacturers working with paint, coatings, plastics, metal finishes, ceramics, printing and other suitable materials, the LS190 can provide an economical way to replace subjective visual inspection with measurable gloss data.
The key is simple: choose the measurement angle according to the product and applicable standard—not merely according to the price or number of features.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
15 Aug 2026