How to Set QC Limits on Linshang LS190 Gloss Meter Malaysia

How to Set QC Limits on Linshang LS190 Gloss Meter Malaysia

 

One of the most useful features of the Linshang LS190 Gloss Meter for routine production inspection is its ability to support upper and lower QC limit settings.

 

Instead of only measuring a surface and obtaining a Gloss Unit (GU) value, manufacturers can establish an acceptable range and use gloss measurements as part of a structured quality-control process.

 

For factories producing painted, coated, plastic, ceramic, metal, printed or other suitable surfaces, this can make routine inspection faster and more consistent.

 

What Is a QC Limit?

 

A QC limit defines the acceptable gloss range for a product.

 

For example, suppose an approved coated component should measure between:

 

Lower Limit: 70 GU

 

Upper Limit: 85 GU

 

A production sample measuring 78 GU is within the specified range.

 

A sample measuring 62 GU is below the lower limit.

 

A sample measuring 91 GU is above the upper limit.

 

This allows operators to make quality decisions based on defined criteria instead of personal visual judgement.

 

Where Should QC Limits Come From?

 

QC limits should not be selected randomly.

 

They may be based on:

 

Customer specifications

 

Product standards

 

Approved reference samples

 

Engineering requirements

 

Historical production data

 

Internal quality procedures

 

If a customer specifies a particular gloss range, that requirement should normally form the basis of the inspection.

 

If no formal specification exists, the company may need to establish an approved reference and develop suitable internal acceptance criteria.

 

Using an Approved Reference Sample

 

An approved sample can be useful when introducing gloss measurement.

 

Suppose repeated measurements of an approved product are around:

 

76 GU

77 GU

78 GU

77 GU

76 GU

 

The company can use this information as part of establishing its internal QC procedure.

 

However, acceptable tolerances should be determined according to actual product requirements rather than simply selecting an arbitrary number around the average.

 

Why Upper and Lower Limits Are Useful

 

Without defined limits, operators may obtain a measurement but still ask:

 

“Is 72 GU acceptable?”

 

A QC range provides context.

 

For example:

 

Specification: 70–80 GU

 

72 GU → within specification

76 GU → within specification

83 GU → outside specification

64 GU → outside specification

 

This simplifies routine production inspection.

 

Example: Powder Coating Factory

 

A powder coating company manufactures metal cabinets.

 

Its approved gloss requirement is:

 

65–75 GU

 

During production, the operator obtains:

 

Sample A: 69 GU

Sample B: 71 GU

Sample C: 68 GU

Sample D: 54 GU

 

Sample D falls below the acceptable range.

 

The production team can investigate possible causes such as:

 

Coating thickness

 

Powder condition

 

Oven temperature

 

Curing time

 

Surface preparation

 

Gloss measurement therefore becomes an early indicator of process variation.

 

Example: Plastic Manufacturing

 

A plastic component may have an approved gloss range of:

 

55–70 GU

 

New production measures:

 

Batch A: 62 GU

Batch B: 64 GU

Batch C: 61 GU

Batch D: 79 GU

 

Batch D is unusually glossy.

 

Possible causes could include changes in raw material, mould condition, processing parameters or surface treatment.

 

Example: Incoming Supplier Inspection

 

QC limits can also be useful when checking purchased components.

 

Suppose an approved supplier component should remain between:

 

75–85 GU

 

The incoming QC team can inspect each delivery.

 

Supplier delivery 1: 79 GU

Supplier delivery 2: 80 GU

Supplier delivery 3: 78 GU

Supplier delivery 4: 63 GU

 

The fourth delivery can be held for investigation before it enters production.

 

This may help prevent larger downstream quality problems.

 

Do Not Make QC Limits Too Tight

 

Setting extremely narrow limits does not automatically improve product quality.

 

If the product specification does not require such tight control, unnecessarily narrow limits may create excessive rejection and production problems.

 

For example, requiring:

 

75.0–75.5 GU

 

would make little sense if the actual product requirement allows much greater variation.

 

QC limits should reflect real functional or appearance requirements.

 

Do Not Make QC Limits Too Wide

 

The opposite problem also exists.

 

If the acceptable range is too wide, significant appearance variation may pass inspection.

 

The goal is to establish limits that realistically represent acceptable product quality.

 

This normally requires cooperation between:

 

QC

 

Production

 

Engineering

 

Management

 

Customer requirements

 

QC Limits Help Different Operators Stay Consistent

 

Without measurable limits, two inspectors may make different decisions about the same surface.

 

Operator A:

 

“Looks acceptable.”

 

Operator B:

 

“Looks too dull.”

 

A defined GU range provides a common reference.

 

This is particularly valuable when companies have multiple shifts or several QC personnel.

 

Combine QC Limits with Consistent Measurement

 

Setting limits alone is not enough.

 

Measurements should also be performed consistently.

 

Control factors such as:

 

Measurement position

 

Surface cleanliness

 

Measurement direction

 

Instrument positioning

 

Measurement geometry

 

Sample condition

 

If the measurement procedure changes, comparison against QC limits becomes less meaningful.

 

Keep Historical QC Records

 

The LS190 supports USB communication with a computer and data export to Excel.

 

Historical records can help identify trends.

 

For example:

 

January average: 78 GU

February average: 77 GU

March average: 75 GU

April average: 73 GU

May average: 70 GU

 

Even if the product remains within the official QC limits, the downward trend may deserve investigation.

 

This allows gloss measurement to support process monitoring, not only PASS / FAIL inspection.

 

Use QC Data for Supplier Management

 

Gloss records can also strengthen supplier quality discussions.

 

Instead of saying:

 

“The latest batch looks different.”

 

your company can show:

 

Approved sample: 79 GU

Previous deliveries: 77–81 GU

Current delivery: 61–64 GU

 

This gives both parties measurable information for investigating the problem.

 

Suitable Applications

 

QC limit functions can be useful for suitable:

 

Paint and coatings

 

Powder coating

 

Plastic products

 

Metal finishes

 

Ceramic products

 

Tiles

 

Printing

 

Packaging

 

Furniture finishes

 

Industrial components

 

The applicable gloss specification should always be confirmed for each product.

 

Why the Linshang LS190 Works Well for Routine QC

 

The LS190 combines several useful features for straightforward factory inspection:

 

60° measurement geometry

 

0–200 GU range

 

1 GU resolution

 

Upper and lower QC limits

 

Portable operation

 

USB computer connection

 

Excel data export

 

For companies that mainly need routine production checking rather than complex laboratory analysis, this combination can provide good value.

 

A Simple QC Workflow

 

A practical gloss inspection process can be:

 

Approved specification → Set QC limits → Measure sample → Compare result → Record data → Investigate abnormal readings

 

This is much more systematic than:

 

Look at product → Decide whether it looks okay

 

The instrument does not replace good QC procedures. It provides measurable data that makes those procedures stronger.

 

Conclusion

 

Setting appropriate upper and lower QC limits is one of the most effective ways to use the Linshang LS190 Gloss Meter for production quality control.

 

Instead of treating gloss measurement as an isolated number, manufacturers can define an acceptable GU range and use it for incoming inspection, production monitoring, finished-goods QC and supplier management.

 

With its 60° measurement geometry, 0–200 GU range, 1 GU resolution, QC judgement capability and USB/Excel data management, the LS190 provides a practical solution for Malaysian manufacturers that want to introduce more objective and traceable surface-quality inspection.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd.

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia

 

🌐 Website: www.mtmpre.com.my

📧 Email: mtmpre@yahoo.com

📱 WhatsApp: +6016-660 7346


 

15 Aug 2026