How to Set QC Limits on Linshang LS190 Gloss Meter Malaysia
How to Set QC Limits on Linshang LS190 Gloss Meter Malaysia
One of the most useful features of the Linshang LS190 Gloss Meter for routine production inspection is its ability to support upper and lower QC limit settings.
Instead of only measuring a surface and obtaining a Gloss Unit (GU) value, manufacturers can establish an acceptable range and use gloss measurements as part of a structured quality-control process.
For factories producing painted, coated, plastic, ceramic, metal, printed or other suitable surfaces, this can make routine inspection faster and more consistent.
What Is a QC Limit?
A QC limit defines the acceptable gloss range for a product.
For example, suppose an approved coated component should measure between:
Lower Limit: 70 GU
Upper Limit: 85 GU
A production sample measuring 78 GU is within the specified range.
A sample measuring 62 GU is below the lower limit.
A sample measuring 91 GU is above the upper limit.
This allows operators to make quality decisions based on defined criteria instead of personal visual judgement.
Where Should QC Limits Come From?
QC limits should not be selected randomly.
They may be based on:
Customer specifications
Product standards
Approved reference samples
Engineering requirements
Historical production data
Internal quality procedures
If a customer specifies a particular gloss range, that requirement should normally form the basis of the inspection.
If no formal specification exists, the company may need to establish an approved reference and develop suitable internal acceptance criteria.
Using an Approved Reference Sample
An approved sample can be useful when introducing gloss measurement.
Suppose repeated measurements of an approved product are around:
76 GU
77 GU
78 GU
77 GU
76 GU
The company can use this information as part of establishing its internal QC procedure.
However, acceptable tolerances should be determined according to actual product requirements rather than simply selecting an arbitrary number around the average.
Why Upper and Lower Limits Are Useful
Without defined limits, operators may obtain a measurement but still ask:
“Is 72 GU acceptable?”
A QC range provides context.
For example:
Specification: 70–80 GU
72 GU → within specification
76 GU → within specification
83 GU → outside specification
64 GU → outside specification
This simplifies routine production inspection.
Example: Powder Coating Factory
A powder coating company manufactures metal cabinets.
Its approved gloss requirement is:
65–75 GU
During production, the operator obtains:
Sample A: 69 GU
Sample B: 71 GU
Sample C: 68 GU
Sample D: 54 GU
Sample D falls below the acceptable range.
The production team can investigate possible causes such as:
Coating thickness
Powder condition
Oven temperature
Curing time
Surface preparation
Gloss measurement therefore becomes an early indicator of process variation.
Example: Plastic Manufacturing
A plastic component may have an approved gloss range of:
55–70 GU
New production measures:
Batch A: 62 GU
Batch B: 64 GU
Batch C: 61 GU
Batch D: 79 GU
Batch D is unusually glossy.
Possible causes could include changes in raw material, mould condition, processing parameters or surface treatment.
Example: Incoming Supplier Inspection
QC limits can also be useful when checking purchased components.
Suppose an approved supplier component should remain between:
75–85 GU
The incoming QC team can inspect each delivery.
Supplier delivery 1: 79 GU
Supplier delivery 2: 80 GU
Supplier delivery 3: 78 GU
Supplier delivery 4: 63 GU
The fourth delivery can be held for investigation before it enters production.
This may help prevent larger downstream quality problems.
Do Not Make QC Limits Too Tight
Setting extremely narrow limits does not automatically improve product quality.
If the product specification does not require such tight control, unnecessarily narrow limits may create excessive rejection and production problems.
For example, requiring:
75.0–75.5 GU
would make little sense if the actual product requirement allows much greater variation.
QC limits should reflect real functional or appearance requirements.
Do Not Make QC Limits Too Wide
The opposite problem also exists.
If the acceptable range is too wide, significant appearance variation may pass inspection.
The goal is to establish limits that realistically represent acceptable product quality.
This normally requires cooperation between:
QC
Production
Engineering
Management
Customer requirements
QC Limits Help Different Operators Stay Consistent
Without measurable limits, two inspectors may make different decisions about the same surface.
Operator A:
“Looks acceptable.”
Operator B:
“Looks too dull.”
A defined GU range provides a common reference.
This is particularly valuable when companies have multiple shifts or several QC personnel.
Combine QC Limits with Consistent Measurement
Setting limits alone is not enough.
Measurements should also be performed consistently.
Control factors such as:
Measurement position
Surface cleanliness
Measurement direction
Instrument positioning
Measurement geometry
Sample condition
If the measurement procedure changes, comparison against QC limits becomes less meaningful.
Keep Historical QC Records
The LS190 supports USB communication with a computer and data export to Excel.
Historical records can help identify trends.
For example:
January average: 78 GU
February average: 77 GU
March average: 75 GU
April average: 73 GU
May average: 70 GU
Even if the product remains within the official QC limits, the downward trend may deserve investigation.
This allows gloss measurement to support process monitoring, not only PASS / FAIL inspection.
Use QC Data for Supplier Management
Gloss records can also strengthen supplier quality discussions.
Instead of saying:
“The latest batch looks different.”
your company can show:
Approved sample: 79 GU
Previous deliveries: 77–81 GU
Current delivery: 61–64 GU
This gives both parties measurable information for investigating the problem.
Suitable Applications
QC limit functions can be useful for suitable:
Paint and coatings
Powder coating
Plastic products
Metal finishes
Ceramic products
Tiles
Printing
Packaging
Furniture finishes
Industrial components
The applicable gloss specification should always be confirmed for each product.
Why the Linshang LS190 Works Well for Routine QC
The LS190 combines several useful features for straightforward factory inspection:
60° measurement geometry
0–200 GU range
1 GU resolution
Upper and lower QC limits
Portable operation
USB computer connection
Excel data export
For companies that mainly need routine production checking rather than complex laboratory analysis, this combination can provide good value.
A Simple QC Workflow
A practical gloss inspection process can be:
Approved specification → Set QC limits → Measure sample → Compare result → Record data → Investigate abnormal readings
This is much more systematic than:
Look at product → Decide whether it looks okay
The instrument does not replace good QC procedures. It provides measurable data that makes those procedures stronger.
Conclusion
Setting appropriate upper and lower QC limits is one of the most effective ways to use the Linshang LS190 Gloss Meter for production quality control.
Instead of treating gloss measurement as an isolated number, manufacturers can define an acceptable GU range and use it for incoming inspection, production monitoring, finished-goods QC and supplier management.
With its 60° measurement geometry, 0–200 GU range, 1 GU resolution, QC judgement capability and USB/Excel data management, the LS190 provides a practical solution for Malaysian manufacturers that want to introduce more objective and traceable surface-quality inspection.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
15 Aug 2026