Myzox CL-28 CL-36 Auto Level for Manhole and Invert Level Checking Malaysia
Myzox CL-28 CL-36 Auto Level for Manhole and Invert Level Checking Malaysia
Correct manhole and invert levels are important in drainage, sewer and infrastructure construction. When a gravity-flow system is installed, the elevation of pipes, channels and manhole connections needs to follow the approved engineering design.
The Myzox CL-28 and CL-36 Auto Levels provide contractors, engineers and survey teams with an optical method for transferring benchmarks and checking elevation differences during drainage and sewer construction.
The Myzox CL-28 offers 28X magnification and ±2.0 mm accuracy for 1 km double-run leveling, while the Myzox CL-36 provides higher 36X magnification and ±1.0 mm accuracy.
MTM Precision Sdn. Bhd. is an authorized distributor of Myzox in Malaysia, supplying professional surveying instruments and accessories for construction and civil engineering applications.
What Is an Invert Level?
In drainage and sewer work, invert level generally refers to the elevation of the lowest internal point of a pipe or channel at a particular location.
Invert elevations are important because they help define the vertical profile and fall of a gravity-flow system.
Project drawings may specify invert levels at locations such as:
Manholes
Pipe connections
Culverts
Drainage outlets
Drainage inlets
Sewer lines
Contractors should always work from the approved engineering drawings and project benchmarks.
Why Is Invert Level Important?
Gravity drainage relies on elevation differences to create the required flow direction.
If pipe or drain elevations are incorrect, potential problems may include:
Insufficient fall
Unintended reverse gradient
Poor drainage performance
Connection problems
Additional excavation
Rework
Reliable elevation control is therefore important throughout installation.
How Can an Auto Level Check Invert Elevation?
An Auto Level establishes a horizontal optical line of sight.
With a known benchmark and leveling staff, the operator can determine the elevation of required points.
A simplified workflow may include:
Identify the approved benchmark.
Set up the Auto Level on stable ground.
Take a backsight reading.
Calculate the Height of Instrument.
Take the required staff reading.
Calculate the point elevation.
Compare the measured elevation with the design invert level.
The exact method depends on access, the location of the point and the project's surveying procedures.
Auto Level for Manhole Construction
Manholes may contain several important elevations.
These can include:
Manhole cover level
Base level
Channel level
Incoming pipe invert
Outgoing pipe invert
Connecting drain elevations
An Auto Level can help transfer a common elevation reference to the manhole location.
This allows contractors to compare actual construction levels against the approved design.
Checking Incoming and Outgoing Pipe Levels
A manhole may have one or more pipes entering and leaving it.
The elevations of these connections need to correspond with the designed drainage profile.
An Auto Level can support the elevation-control process by helping determine actual site levels.
The required difference between incoming and outgoing invert levels should be obtained from the engineering design rather than assumed in the field.
Myzox CL-28 for General Drainage Work
The Myzox CL-28 provides:
Magnification: 28X
Objective Aperture: 36 mm
Minimum Focusing Distance: 0.4 m
1 km Double-Run Leveling Accuracy: ±2.0 mm
Self-Leveling Range: ±15′
Horizontal Circle: 360°
Weight: Approximately 1.3 kg
The CL-28 can be considered for routine applications such as:
Building drainage
Residential developments
Commercial projects
Open drains
General pipe installation
Manhole work
Myzox CL-36 for Civil Engineering and Infrastructure
The Myzox CL-36 provides:
Magnification: 36X
Objective Aperture: 36 mm
Minimum Focusing Distance: 0.4 m
1 km Double-Run Leveling Accuracy: ±1.0 mm
Self-Leveling Range: ±15′
Horizontal Circle: 360°
Weight: Approximately 1.3 kg
Its higher magnification and specified accuracy can make it attractive for:
Sewer projects
Road drainage
Infrastructure projects
Large civil engineering sites
Industrial developments
Longer drainage alignments
Invert Level vs Cover Level
These two terms should not be confused.
Invert Level generally refers to the bottom internal elevation of the pipe or drainage channel.
Cover Level generally refers to the elevation at the top of the manhole or cover reference.
The vertical difference between these elevations is important for construction, but the exact dimensions should be obtained from the project drawings.
Auto Level for Sewer Pipe Installation
During sewer installation, elevation checks may be required at different stages.
These may include:
Trench excavation
Bedding preparation
Pipe installation
Manhole connections
Final verification
The Auto Level provides elevation information. Pipe alignment, gradient and other installation requirements should follow the approved design and appropriate construction methods.
Auto Level for Culvert Invert Level
Culverts also require appropriate inlet and outlet elevations.
An Auto Level can assist with checking:
Excavation elevation
Bedding elevation
Inlet invert
Outlet invert
Connection to surrounding drainage
For larger road and infrastructure projects, the CL-36 may be useful when longer sighting distances are encountered.
Common Invert Level Checking Mistakes
Wrong Benchmark
An incorrect starting elevation can affect every subsequent calculation.
Confusing Cover Level and Invert Level
Always confirm which design elevation is being checked.
Incorrect Staff Position
The leveling staff must correspond with the actual point being measured.
Staff Not Vertical
A tilted staff can affect the observed reading.
Calculation Error
Carefully check Height of Instrument and Reduced Level calculations.
Incorrect Design Information
Always work from the latest approved project drawings.
Why Recheck Critical Drainage Levels?
Drainage and sewer installations can become difficult or expensive to correct after backfilling or subsequent construction.
Critical elevations should therefore be verified according to the project's quality-control procedures before work is covered.
CL-28 or CL-36 for Drainage Contractors?
Choose the CL-28 when:
General building drainage is involved
Working distances are moderate
28X magnification is sufficient
±2.0 mm leveling specification meets project requirements
Consider the CL-36 when:
Larger civil projects are involved
Sewer or infrastructure work is common
Higher 36X magnification is preferred
±1.0 mm leveling specification is required
Frequently Asked Questions
Can an Auto Level measure invert level?
An Auto Level can be used with a leveling staff and appropriate surveying procedures to determine elevations associated with pipe and drainage invert points.
What is invert level in drainage?
It generally refers to the elevation of the lowest internal point of a pipe or channel at a specified location.
Can Myzox CL-28 be used for manhole construction?
Yes. It can assist with general benchmark transfer and elevation checking for manhole and drainage work.
Is Myzox CL-36 suitable for sewer projects?
Yes. Its 36X magnification and ±1.0 mm leveling specification make it an option for more demanding civil engineering applications.
Is invert level the same as manhole cover level?
No. They refer to different elevations within the drainage or sewer system.
Should invert levels be checked before backfilling?
Critical installed elevations should be verified according to the project's construction and quality-control requirements before they become inaccessible.
Myzox Auto Level for Drainage and Sewer Contractors Malaysia
MTM Precision supplies Myzox CL-28, CL-36 and professional surveying accessories in Malaysia.
As an authorized distributor of Myzox in Malaysia, we support drainage contractors, sewer contractors, civil engineers, infrastructure contractors and survey teams requiring professional equipment for manhole and invert level checking.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Website: www.mtmpre.com.my
Email: mtmpre@yahoo.com
WhatsApp: +6016-6607346
Contact MTM Precision for enquiries about the Myzox CL-28, CL-36 Auto Level and professional surveying equipment for drainage, sewer and infrastructure projects in Malaysia.
16 Aug 2026