How to Measure Up to 500 kgf Using the Landtek FM-207-500K Malaysia
How to Measure Up to 500 kgf Using the Landtek FM-207-500K Malaysia
Measuring a force of up to 500 kgf requires more than simply connecting a hook to a handheld meter. The sensor must be correctly aligned, the fixture must be strong enough, and the applied load must remain within the instrument’s measuring range.
The Landtek FM-207-500K Digital Force Gauge is designed for high-capacity push-and-pull force measurement. It provides a measuring range of:
±500 kgf
±4900 N
±1100 lbf
Its external sensor configuration makes it suitable for industrial tension, compression, load and breaking-force tests in Malaysia.
What Is 500 kgf?
The unit kgf means kilogram-force. It represents the force exerted by gravity on a mass of one kilogram under standard conditions.
Approximately:
1 kgf = 9.80665 N
100 kgf = 980.7 N
500 kgf = 4903 N
The FM-207-500K displays up to approximately 4900 N, making it suitable for applications that exceed the capacity of common 50 kg or 100 kg handheld force gauges.
However, a 500 kgf force measurement should not be confused with simply weighing a 500 kg object. The actual force depends on the test direction, fixture, loading method and movement of the sample.
What Is Required for a 500 kgf Force Test?
A complete testing arrangement normally consists of:
Landtek FM-207-500K display unit
External force sensor
Suitable suspension links or connectors
High-capacity test stand or loading mechanism
Correct pulling or compression fixture
Secure mounting structure
Test sample
Appropriate safety protection
The force gauge measures the applied force. It does not automatically generate the pulling or pushing force.
Depending on the application, the load may be applied using a manual, hydraulic, pneumatic, electric or customised mechanical system.
Step 1: Identify the Required Test
Before installing the instrument, determine whether the application requires a pull test or a push test.
Pull or Tension Test
A tension test pulls the sample in opposite directions.
Typical examples include:
Pulling a cable from a terminal
Testing a hook or fastener
Measuring wire-joint strength
Checking the extraction force of an assembled component
Measuring the force required to separate two parts
Push or Compression Test
A compression test applies force toward the sample.
Typical examples include:
Compressing a spring
Testing a structural component
Measuring closure or pressing force
Checking deformation under load
Testing a product’s resistance to compression
The sensor and fixture must be arranged according to the direction of force.
Step 2: Select a Suitable Measuring Range
The expected test force should fall comfortably within the instrument’s range.
The FM-207-500K is suitable when the anticipated force may reach several hundred kilograms-force but remains below 500 kgf.
Avoid choosing a gauge solely because its maximum range is higher. A very high-capacity gauge may not be suitable for accurately evaluating extremely small forces.
If the expected force is only 5 kgf or 10 kgf, a lower-range force gauge may provide more useful resolution. If the expected force may exceed 500 kgf, a higher-capacity model should be selected.
Step 3: Check the Fixture and Connection Points
Every part of the testing system must have an adequate load capacity, including:
Hooks
Bolts
Shackles
Suspension links
Clamps
Mounting plates
Test stands
Support structures
A fixture failure during a high-force test can damage the instrument and create a serious safety hazard.
Do not assume that a connector is suitable simply because it fits the sensor. Its rated load and condition must also be checked.
Step 4: Install the External Sensor Correctly
Mount the sensor securely and align it with the direction of the applied force.
The loading force should pass through the sensor in a straight line. Avoid:
Side loading
Twisting
Bending
Off-centre loading
Sudden impact
Shock loading
Incorrect alignment can produce unstable readings, reduce measurement reliability or damage the sensor.
For repetitive testing, a properly designed fixture helps maintain consistent sensor alignment and sample positioning.
Step 5: Connect and Power the Instrument
Connect the external sensor to the FM-207-500K display unit according to the operating instructions.
The instrument can be powered using:
AA batteries
A suitable external DC power supply
Check that the sensor cable is properly connected and positioned away from moving parts.
Turn on the instrument and allow the display to stabilise before beginning the test.
Step 6: Select the Measurement Unit
Choose the measurement unit required for the test report:
kgf
N
lbf
Newton is commonly used in engineering and technical documentation, while kgf may be easier for some operators to interpret during general industrial testing.
Use the same unit consistently when comparing production batches or recording quality-control results.
Step 7: Zero the Gauge
After installing the sensor, fixture and accessories, ensure that no unintended test load is being applied.
Press the zero function to clear the weight or initial force caused by the installed fixture.
The display should return to zero before every new test.
If the reading does not remain stable at zero, inspect:
Fixture alignment
Sensor mounting
Cable connection
Residual load
Environmental vibration
Do not begin the test until the system is stable.
Step 8: Select Real-Time or Peak Mode
The correct measurement mode depends on the test objective.
Real-Time Mode
Use real-time measurement when you need to observe the force while the load increases or decreases.
This is useful for:
Monitoring compression force
Checking force changes
Holding a sample at a specified load
Adjusting machinery or fixtures
Peak Mode
Use peak-value measurement when you need to capture the maximum force reached during the test.
This mode is suitable for:
Breaking-force tests
Cable pull-out tests
Maximum compression tests
Release-force tests
Destructive testing
The FM-207-500K retains the highest recorded value so the operator can read it after the test.
Step 9: Apply the Load Gradually
Begin applying the load slowly and smoothly.
Watch the displayed reading and stop the test if:
The required test force has been reached
The sample breaks or separates
The fixture becomes unstable
The sensor moves out of alignment
The overload warning activates
The reading approaches the instrument’s maximum capacity
The FM-207-500K provides a buzzer warning when the applied force exceeds approximately 110% of full scale. This warning is a protection feature, not an additional working range.
The gauge’s safe-load specification should never be treated as permission to conduct routine measurements above 500 kgf.
Step 10: Record and Review the Result
After completing the test, record:
Maximum measured force
Measurement unit
Test direction
Sample identification
Fixture used
Test speed or loading method
Date and operator
Pass or fail result
The FM-207-500K can store up to 99 measurement records. Data output may also be available through USB or an optional Bluetooth connection, depending on the supplied accessories.
Consistent test conditions are essential when comparing different products or production batches.
Common Mistakes During High-Force Testing
Using an Underrated Fixture
The gauge may support 500 kgf, but an unsuitable clamp, hook or mounting plate may fail at a much lower force.
Applying Force at an Angle
Angular or side loading can affect the measurement and damage the sensor.
Starting Without Zeroing
The weight of the fixture or an existing preload may be included in the result.
Applying the Load Too Quickly
Sudden loading can create an impact force that is higher than the intended test force.
Testing Too Close to Maximum Capacity
Repeatedly operating at the maximum range increases the risk of overload, especially when the sample breaks suddenly.
Using a 500 kgf Gauge for Very Small Forces
A lower-capacity gauge may provide better resolution and sensitivity for small-force applications.
Frequently Asked Questions
Can the FM-207-500K lift or pull 500 kg automatically?
No. It measures force but does not generate it. A separate test stand or loading mechanism is required.
Can it perform destructive testing?
Yes, it can capture the peak force when a sample breaks, provided the expected force and fixture capacity remain within safe limits.
Is a test stand necessary?
For high-force testing, a stable test stand or engineered fixture is strongly recommended for safety, alignment and repeatability.
Can it measure both tension and compression?
Yes. The sensor and fixtures must be installed according to the required loading direction.
Should I choose the 500 kgf model for every force test?
No. The correct model depends on the expected force. A lower-capacity gauge may be more appropriate for small forces, while tests above 500 kgf require a higher-range system.
Get the Correct Force Gauge and Fixture in Malaysia
MTM Precision supplies the Landtek FM-207-500K Digital Force Gauge for industrial push, pull, tension and compression testing.
Before ordering, send us:
A photo or video of the product being tested
Expected minimum and maximum force
Push or pull test requirement
Sample dimensions
Required measurement unit
Frequency of testing
Preferred test stand or fixture
Calibration or reporting requirements
This information helps determine whether the FM-207-500K and the proposed testing arrangement are suitable for your application.
Contact MTM Precision
MTM Precision Sdn. Bhd. (744811-A)
Telephone: +603-8080 7172
WhatsApp: +6019-665 7346 / +6016-660 7346
Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my
Website: www.mtmpre.com.my
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar Lapan Belas,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Supply and technical support are available throughout Malaysia, including Selangor, Kuala Lumpur, Johor, Penang, Perak, Melaka, Negeri Sembilan, Pahang, Kedah, Perlis, Terengganu, Kelantan, Sarawak and Sabah.
16 Sep 2026